PowMr T20 T30 T40

Contents

PowMr MPPT PWM Solar Charge Controller User Manual

Models: T20, T30, T40

1. Introduction

This document provides instructions for the PowMr MPPT PWM Solar Charge Controller, available in T20, T30, and T40 models. This controller is designed for intelligent, efficient, and energy-saving management of solar charging systems.

It features an efficient charging function that automatically tracks the maximum power point, offering 10-30% higher charging efficiency compared to ordinary controllers. It also boasts standby energy-saving capabilities, consuming only 10mA-15mA in standby mode, which is more than 30% less energy than conventional controllers.

Note: This controller is a compatible MPPT + PWM solar controller, not a 100% true MPPT controller.

The controller includes a dual timer function for evening, interval, and dawn working times, allowing users to customize operation based on their specific needs.

2. Product Overview

The PowMr solar charge controller integrates an LCD screen for easy monitoring and operation. It features multiple protection functions to ensure the safety and longevity of your solar system components.

PowMr MPPT T20 Solar Controller, 20A 30A 40A, 12V 24V
Figure 1: PowMr MPPT PWM Solar Charge Controller (T20 model shown)
PowMr MPPT T40 Solar Controller front view
Figure 2: PowMr MPPT T40 Solar Controller front view
PowMr MPPT T40 Solar Controller rear view showing heat sink
Figure 3: Rear view of the T40 model, highlighting the heat sink for efficient cooling.

3. Setup and Installation

Before connecting, ensure all components are correctly rated for your system voltage (12V or 24V). The controller automatically detects the system voltage.

3.1 Connection Order

  1. Connect the Battery: Connect the battery to the charge controller first. Ensure correct polarity (+ to + and - to -). The controller will detect the battery voltage.
  2. Connect the Solar Panel: Connect the solar panel to the charge controller. Ensure correct polarity.
  3. Connect the Load: Connect the DC load to the charge controller. Ensure correct polarity.

Warning: Always connect the battery first and disconnect the solar panel and load before disconnecting the battery to prevent damage to the controller.

Wiring diagram for PowMr MPPT T40 Solar Charge Controller showing Solar Panel, Battery, and Load terminals, along with USB and Thermo scope ports.
Figure 4: Connection terminals and ports on the T40 controller. Note the Solar Panel Terminal, Battery Terminal, Load Terminal, USB 5V 1.0A/1000mA output, and Thermo scope port.

3.2 USB Output

The controller includes a USB 5V 1.0A/1000mA output for charging mobile phones and other compatible devices.

3.3 Temperature Probe

A thermo scope (temperature probe) must be plugged into the designated port for accurate temperature compensation, which is crucial for optimal battery charging.

4. Operating Instructions

The controller features an LCD display and several buttons for monitoring and setting parameters.

LCD operating interface description with numbered labels for display elements and buttons.
Figure 5: LCD Operating Interface Description

4.1 LCD Display Elements

  • 1. Solar panels: Indicates solar panel activity.
  • 2. Charging current: Displays the current flowing from solar panels to the battery.
  • 3. Evening System Status: Shows the status during evening operation.
  • 4. Load stop working: Indicates when the load is disconnected.
  • 5. Charging: Indicates battery charging status.
  • 6. Discharge: Indicates battery discharging status.
  • 7. Battery voltage: Displays the current battery voltage.
  • 8. Battery percentage: Shows the battery's state of charge.
  • 9. Discharge stop voltage: The voltage at which the load is disconnected to protect the battery.
  • 10. Load working: Indicates when the load is connected and active.
  • 11. System Status: General system status indicator.
  • 12. Undervoltage restore power supply voltage: The voltage at which the load is reconnected after undervoltage protection.
  • 13. Charging voltage: The voltage at which the battery is being charged.
  • 14. Charging logo: Visual indicator for charging.
  • 15. Charging feature: Additional charging information.

4.2 Button Functions

  • Left Button (Setup): Used to enter parameter setting mode and cycle through different settings.
  • '+' Button (Plus): Increases the value of a selected parameter.
  • '-' Button (Minus): Decreases the value of a selected parameter.
  • Right Button (On/Off/Reset): Toggles the load on/off. Long press (5 seconds) to reset the controller.

4.3 Dual Timer Load Control Mode

The controller supports a dual timer function for load control, allowing for flexible operation during evening, interval, and dawn periods. This is particularly useful for lighting applications.

Evening Interval Dawn Description
00H --H --H After dark (night) open workload until dawn (dawn) load stops working.
24H --H --H Normally open mode, the load has been working until the battery (undervoltage) automatic protection, load stop working.
01H 00H 00H Interval and Dawn are set to 00H, after dark 1H off load after of work (can set).
23H 00H 00H Interval and Dawn are set to 00H, after dark 23H off load after of work (can set).
05H 07H 03H (Evening) work load 5H, (interval) to stop supplying the load 7H, (Dawn) work load 3H (can set).

Warning: If (night) setting (00H) or (24H), (time interval and dawn) would prohibit these two time periods set.

4.4 Operation Demonstration Video

Video 1: Demonstration of the controller's display navigation and button operation.

5. Maintenance

To ensure optimal performance and longevity of your solar charge controller, regular maintenance is recommended:

  • Cleanliness: Keep the controller clean and free from dust and debris. Use a dry cloth for cleaning.
  • Connections: Periodically check all wiring connections to ensure they are tight and secure. Loose connections can cause overheating and damage.
  • Ventilation: Ensure the controller is installed in a well-ventilated area to prevent overheating, especially for models with heat sinks (e.g., T40).
  • Temperature Probe: Verify that the temperature probe is securely connected and positioned correctly for accurate temperature readings, which are essential for proper battery charging.

6. Troubleshooting

The controller is equipped with various protection features. If you encounter issues, check the following:

  • No Display/Power:
    • Check battery connections and ensure the battery has sufficient charge.
    • Verify that the battery voltage is within the 12V/24V auto-detection range.
  • Load Not Working:
    • Check load connections and ensure correct polarity.
    • Verify that the load is not exceeding the controller's rated current.
    • Check the load control settings (Evening, Interval, Dawn) to ensure the load is scheduled to be ON.
    • The controller has over-discharge protection; if the battery voltage drops below the discharge stop voltage, the load will be disconnected. It will reconnect when the battery recovers to the undervoltage restore power supply voltage.
    • Press the On/Off button to manually toggle the load.
  • Battery Not Charging:
    • Check solar panel connections and ensure correct polarity.
    • Verify that the solar panel is receiving sufficient sunlight.
    • Ensure the solar panel's open circuit voltage is within the specified range (18-24V for 12V system, 36-48V for 24V system).
    • Check for any shading on the solar panels.
  • Error Messages:
    • The display may show "Parameter error (±5%)" if settings are outside the acceptable range. Adjust parameters accordingly.
  • Protection Features: The controller includes:
    • Over-charge and discharge protection
    • Battery reverse discharge protection
    • Battery reverse polarity protection
    • Battery under voltage protection
    • Short-circuit protection
    If any of these protections are triggered, the controller will automatically take action to protect the system. Identify and resolve the underlying cause.

7. Specifications

Parameter/Model T10 T20 T30 T40
Maximum Power Current 10A 20A 30A 40A
Installation Line mm2 4mm2 8mm2 10mm2 12mm2
Installation Line (AWG) 10 (AWG) 8 (AWG) 7 (AWG) 6 (AWG)
Battery capacity configuration 100AH 200AH 300AH 400AH
Dimensions 143×89×46 mm 187*97*61 mm
System load loss ≤13mA
Loop Buck ≤100mV
Battery float voltage 13.8V 12V system / 27.6V 24V system
Battery under voltage protection 10.6V 12V system / 21.2V 24V system
Battery (under voltage) recovery voltage 12.6V 12V system / 25.2V 24V system
Charging mode Compatible MPPT+PWM
Operating Temperature -10~60°C
Storage Temperature -30~70°C
Humidity requirements ≤90%, No condensation
Temperature compensation -4mV/Cell/°C
Temperature Probe NTC 100K thermistats (built components)
Maximum open circuit voltage of the solar panel 18V-24V 12V system, 36V-48V 24V system
Solar panels maximum open circuit voltage (V) ≤48V
(Cases) 12V system standard configuration
The peak voltage of the solar cell panel 18V-25V
Peak power of solar cell panel 50W-130W 100W-260W 200W-380W ≤500W
Detailed specifications table for PowMr Solar Charge Controllers T10, T20, T30, T40 models.
Figure 6: Detailed Specifications Table

7.1 Key Features

Feature Description
LCD screen display Provides clear system status and parameter information.
Easy operation interface Intuitive buttons for setting and monitoring.
MPPT+PWM charging mode Efficient charging with automatic maximum power point tracking.
Parameter user can reset Overload Allows users to adjust overload parameters.
A key to restore the factory settings Quickly revert to default settings.
A key to open and close the load Manual control over the connected DC load.
Battery reverse discharge protection Prevents battery power from flowing back to the solar panel at night.
Battery reverse polarity protection Protects the controller and battery from damage due to incorrect battery connection.
Battery under voltage protection Disconnects the load to prevent over-discharging the battery.
Short-circuit protection Protects against short circuits in the load or battery circuits.
USB 5V charging 500mA for mobile phone Convenient charging port for small electronic devices.
Automatic temperature compensation function Adjusts charging parameters based on ambient temperature for optimal battery health.
Table listing key features of the solar charge controller including LCD display, charging modes, and various protections.
Figure 7: Key Features Table

8. Warranty and Support

This product is CE certified, indicating compliance with European safety, health, and environmental protection standards.

For any technical support or warranty inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt for warranty claims.

9. User Tips

  • While the controller offers advanced features, some users have noted that software improvements could enhance its overall performance.
  • Ensure proper ventilation around the controller to prevent overheating, especially during high current operation.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.