1. Introduction
The RETEKESS TD157 Wireless Restaurant Guest Paging System is designed to streamline customer flow and improve service efficiency in various establishments. This system features a keypad transmitter and multiple coaster pagers, providing reliable communication without the need for complex wiring.
Video: Overview of the RETEKESS TD157 Paging System in use.
The system is ideal for restaurants, cafes, food trucks, hotels, churches, clinics, and other venues where efficient guest notification is essential.
Image: The RETEKESS TD157 Paging System, featuring a keypad transmitter and 16 pagers.
2. Package Contents
Please check the box for the following items:
- 1 x Keypad Transmitter
- 16 x Pagers (Receivers)
- 1 x Power Adaptor
- 1 x English Manual
Image: Visual representation of the items included in the package.
3. Setup Instructions
3.1 Initial Preparation
- Ensure all pagers are placed in the main unit's charging slots.
- Allow pagers to charge for at least 20 minutes before initial operation.
3.2 Power On/Off
- Power On: Place all pagers in the main unit's charging slots. Once the main unit is powered on, the pagers will automatically turn on.
- Power Off: Place all pagers in the main unit's charging slots. Input "999" on the keypad and press the [Call] button to shut down the pagers.
Image: One-button shutdown feature using the keypad.
3.3 Entering Setup Mode
To enter the setup mode:
- Press the [Call] button and the [Clear] button simultaneously until the host screen displays "[F1]".
- This indicates you are in the mode selection interface.
- Input a number from "1" to "4" on the keypad to select the desired mode (e.g., "1" for Host ID setting, "2" for Extension ID setting, "3" for Buzzer switch setting, "4" for Prompt duration setting).
- Press the [Call] button to enter the selected setting mode.
- After completing your settings, press [Clear] to exit the setting mode. The standby screen will display "--".
3.4 F1 Host ID Number Setting
In setup mode, when the default screen flashes the current host ID number:
- Enter a new number (001-999) using the keypad.
- Press the [Call] button to save the new Host ID.
- Note: Do not modify the host base number unless necessary. If modified, all pagers will need to be reset. Do not set the base number to "000".
3.5 F2 Extension ID Number Setting
To set individual pager IDs:
- Remove all pagers from the base unit.
- Enter setup mode (as described in 3.3) and select "2" for F2 Extension ID setting. The screen will flash "01".
- Insert the pager you wish to set into a charging slot. The pager's function light will flash.
- Within 3 seconds, input the new ID number (1-998) on the keypad and press the [Call] button to save. The pager will flash to confirm successful setting.
- Remove the pager and repeat for other pagers.
- After all pagers are set, press [Clear] to exit.
- Note: Do not set "99" or "999" as an extension number, as these are reserved for shutdown commands. To modify an existing pager ID, simply overwrite it with a new number.
4. Operating Instructions
4.1 Calling Pagers
To call a pager, simply enter its assigned ID number on the keypad and press the [Call] button. The corresponding pager will activate according to its set prompt mode.
4.2 F3 Buzzer Switch Setting
This setting controls whether the pager beeps when called:
- Enter setup mode and select "3" for F3 Buzzer switch setting. The screen will flash "01".
- Input "0" for off or "1" for on using the keypad.
- Press the [Call] button to save your selection.
Image: Illustration of the two available prompt modes: Flash and Flash + Beep.
4.3 F4 Prompt Duration Setting
This setting controls how long the pager's alert lasts:
- Enter setup mode and select "4" for F4 Prompt duration setting. The screen will flash "01".
- Input a duration from "1" to "99" seconds using the keypad.
- Press the [Call] button to save your selection.
4.4 Long Working Distance
The system utilizes AM technology, which provides strong penetration ability, allowing signals to pass through multiple walls. The actual working distance is affected by the environment:
- Indoor working distance: up to 100m (328ft)
- Working distance in open area: up to 300m (984ft)
Image: Diagram illustrating the signal penetration capabilities of the AM technology.
4.5 Multiple Keyboards Support
The system supports multiple keypad transmitters calling the same pager, which is useful for larger establishments or multiple service points.
Image: Illustration of multiple keyboards calling the same pager.
5. Maintenance
5.1 Cleaning
- The keypad is designed to be responsive and easy to clean. Accidental spills of oil and water will not affect normal use.
- To clean the keypad and pagers, use a soft, damp cloth. Avoid abrasive cleaners or solvents.
- Unplug the power adaptor from the AC outlet before attempting any maintenance or cleaning.
Image: The touch keyboard is designed to withstand minor spills.
5.2 Battery Care
- The pagers have a built-in 3.7V 300mAh rechargeable lithium battery.
- A fully charged pager can provide up to 20 hours of standby time.
- Always place pagers in the charging slots when not in use to ensure they are ready for operation.
- Risk of explosion if the battery is replaced by an incorrect type. Dispose of used batteries according to local regulations.
Image: Pager battery capacity and standby time.
6. Troubleshooting & Safety Guidelines
6.1 General Troubleshooting
- Pager not responding: Ensure the pager is fully charged and within the transmission range. Check if the pager ID is correctly set.
- Interference: If you experience interference, try reorienting or relocating the receiving antenna. Ensure the equipment is connected to a different circuit than other interfering devices.
- Damaged components: Do not operate the system with damaged antennas or chargers. Contact customer support for assistance.
6.2 Safety Guidelines
Please read and adhere to the following safety guidelines to ensure safe operation and compliance with RF energy exposure limits:
- RF Energy Exposure: This radio uses electromagnetic energy. Ensure you are aware of and control your exposure to meet occupational requirements. Do not operate the transmitter in areas sensitive to electromagnetic radiation (e.g., hospitals, aircraft, blasting sites).
- Antenna: Do not operate the radio without a proper antenna attached. Use only the antenna supplied or specifically authorized by the manufacturer.
- Unauthorized Modifications: Changes or modifications not expressly approved by the manufacturer may void your authority to operate this radio and could violate regulations.
- Transmission Time: Do not transmit for more than 50% of the total radio use time to avoid exceeding RF exposure compliance requirements.
- Interference: Turn off the radio in areas where signs are posted to avoid interference with other devices or systems.
- Batteries: Exercise care when handling batteries. Avoid short-circuiting terminals with conductive materials (jewelry, keys, etc.) to prevent burns.
- Charger: Do not use the charger outdoors or in moist environments. Do not disassemble or operate a damaged charger.
- Vehicle Safety: Do not place a portable radio in the area over an airbag or in the airbag deployment area.
- Hearing Protection: Use the lowest volume necessary. Turn down the volume before adding a headset or earpiece. Limit the time you use headsets or earpieces at high volume to prevent hearing damage.
- Operating Temperature: The operating temperature of the equipment must not exceed the specified range.
7. Specifications
| Feature | Specification |
|---|---|
| Model Number | TD157 |
| Brand Name | RETEKESS |
| Keypad Dimension | 238 x 151 x 30 mm (9.37 x 5.94 x 1.18 inches) |
| Pager Dimension | 106 x 51 x 11 mm (4.17 x 2.01 x 0.43 inches) |
| Material | ABS |
| Transmit Power | 240mW |
| Frequency | 433MHz |
| Power Supply | DC12V/1A |
| Launch Distance | >800M (in Open Area), approx. 300m (984ft) open field, 100m (328ft) indoor |
| Support Receivers | Up to 998 pagers (16 included in set) |
| IP Grade | IP32 |
| Pager Battery | Built-in 3.7V 300mAh rechargeable lithium battery |
| Receiving Sensitivity | -114dB |
| Standby Time | Approx. 20 hours (fully charged) |
| Certifications | CE, FCC, RoHS |
Image: Detailed dimensions of the keypad and pagers.
8. User Tips
- For optimal range, ensure the keypad transmitter's antenna is unobstructed and positioned centrally within the service area.
- Regularly check pager battery levels by placing them on the charging base.
- Consider using the "Flash + Beep" prompt mode in noisy environments and "Flash only" in quieter settings like clinics or churches.
- If using multiple keypad transmitters, ensure they are configured to call the same pagers as needed for seamless operation.
9. Warranty & Support
For assistance with repairs, service, or a list of approved accessories, please contact RETEKESS customer support:
- Email: support@retekess.com
- Website: www.retekess.com
- Facebook: facebook.com/RetekessWirelessSystem
EU Importer: Germany Retevis Technology GmbH, Uetzenacker 29, 38176 Wendeburg.
Manufacturer: Henan Eshow Electronic Commerce Co., Ltd., 7/F, Sanjiang Building, No.170 Nanyang Road, Huiji District, Zhengzhou, Henan, China.
This product is made in China.
A PDF version of the user manual is available for download: User manual (PDF)