1. Introduction
The SUMRY MPS V-MAX 10.2KW Hybrid Solar Inverter is a versatile and powerful solution for both on-grid and off-grid solar energy systems. Designed for efficiency and reliability, it features dual MPPT technology, allowing for optimal solar energy harvesting even under uneven sunlight conditions. This inverter is capable of running without a battery, providing flexibility for various power needs, and includes comprehensive protection features to ensure safe and stable operation.
Key Features:
- Pure Sine Wave Inverter (On/Off Grid)
- Inverter running without battery capability
- High PV input voltage range (90-500VDC)
- Built-in 160A MPPT solar charger (for 8.2kW/10.2kW models)
- Dual communication ports for Battery communication (BMS) and WiFi communication (RS232/RS485)
- Dual output and Dual PV input for enhanced flexibility
- Touch button interface for easy control
- WiFi & GPRS available for iOS and Android monitoring
- Built-in Lithium battery automatic activation


2. Specifications
This section provides detailed technical specifications for the SUMRY MPS V-MAX 10.2KW Hybrid Solar Inverter.
General Specifications:
- Dimensions (D*W*H): 530mm * 420mm * 160mm
- Weight: 17KG
- Output Type: SINGLE
- Origin: Mainland China
- Certification: CE, FCC, RoHS
- Is Smart Device: Yes

Detailed Product Data Sheet (10.2KW Model):
| Parameter | Value |
|---|---|
| Phase | 1-phase |
| Rated Output Power | 10200W/10200VA |
| Maximum Solar Charging Current | 160A |
| GRID-TIE OPERATION | |
| PV Input (DC) Nominal DC Voltage/Maximum DC Voltage | 360/500VDC |
| Start-up Voltage / Initial Feeding Voltage | 90VDC/120VDC |
| MPPT Voltage Range | 90-450VDC |
| Maximum Input Current | 2/18A |
| GRID OUTPUT (AC) | |
| Nominal Output Voltage | 220/230/240VAC |
| Output Voltage Range | 195-253VAC |
| Nominal Output Current | 44.3A |
| Power Factor | >0.99 |
| EFFICIENCY | |
| Maximum Conversion Efficiency (DC/AC) | 98% |
| TWO LOAD OUTPUT POWER | |
| Full Load | 10200W |
| Maximum Main Load | 10200W |
| Maximum Second Load (battery mode) | 3400W |
| Maximum Load Cut Off Voltage | 52VDC |
| Maximum Load Return Voltage | 54VDC |
| OFF-GRID OPERATION | |
| AC Start-up Voltage / Auto Restart Voltage | 120-140VAC/180VAC |
| Acceptable Input Voltage Range | 90-280VAC or 170-280VAC |
| Frequency Range | 59-61±1HZ |
| Maximum AC Input Current | 60A |
| PV Input (DC) | |
| Nominal DC Voltage/Maximum DC Voltage | 360/500VDC |
| MPPT Voltage Range | 90-450VDC |
| Maximum Input Current | 2/18A |
| BATTERY MODE OUTPUT (AC) | |
| Nominal Output Voltage | 220/230/240VAC |
| Output Waveform | Pure sine wave |
| Efficiency (DC to AC) | 94% |
| BATTERY & CHARGER | |
| Nominal DC Voltage | 48VDC |
| Maximum Solar Charging Current | 160A |
| Maximum AC Charging Current | 140A |
| Maximum Solar+AC Charging Current | 160A |

3. Setup and Installation
Proper installation is crucial for the safe and efficient operation of your SUMRY Hybrid Solar Inverter. Please follow these guidelines carefully.
3.1 Product Overview and Port Identification
Familiarize yourself with the inverter's layout and connection ports before beginning installation.

3.2 System Architecture
The inverter supports various configurations for solar power, utility/generator input, battery storage, and load output.

3.3 Wiring Instructions
Ensure all wiring is done by a qualified professional and adheres to local electrical codes. The video below demonstrates the wiring process.
Video 1: Unboxing and wiring demonstration for the SUMRY MPS V-MAX Inverter, showing connections for PV, AC input, AC output, and battery.
- PV Input (Solar Panels): Solar panels are recommended to be connected in series. Connect PV1+ and PV1- to the first solar array, and PV2+ and PV2- to the second solar array.
- AC Input: Connect the AC grid or generator input to the AC IN (L, N, Ground) terminals.
- AC Output (Loads): Connect your main loads to the MAIN OUT (L, N) terminals. For secondary loads, use the SECOND OUT (L, N) terminals.
- Battery Connection: Connect your 48V battery bank to the BATTERY (+, -) terminals. Ensure correct polarity.

3.4 Battery Compatibility
The inverter is compatible with various 48V battery types, including:
- Flooded (FLD)
- Gel (GEL)
- Lithium-iron phosphate (LI)
- Lithium-ion (LI)
- AGM/Sealed (SLD)
- User custom Battery (USER)
For a 48V system, you typically connect four 12V batteries in series.

4. Operation
This section covers the basic operation of your SUMRY Hybrid Solar Inverter, including understanding the display, buttons, and indicators.
4.1 LCD Display and Function Buttons
The inverter features an LCD display and several function buttons for monitoring and configuration.

Function Keys:
- ESC: To exit setting mode.
- UP: To go to previous selection.
- DOWN: To go to next selection.
- ENTER: To confirm the selection in setting mode or enter setting mode.
LED Indicators:
- INV/AC (Green): Solid On - Output is powered by utility in Line mode. Flashing - Output is powered by battery or PV in battery mode.
- CHG (Green): Solid On - Battery is fully charged. Flashing - Battery is charging.
- FAULT (Red): Solid On - Fault occurs in the inverter. Flashing - Warning condition occurs in the inverter.
4.2 Remote Monitoring (SmartESS App)
The inverter can be monitored and controlled remotely via the SmartESS App, available on both iOS and Android platforms. This requires the 'with WIFI' version of the inverter.

5. Maintenance
Regular maintenance helps ensure the longevity and optimal performance of your inverter. Always disconnect all power sources before performing any maintenance.
- Cleaning: Periodically clean the inverter's exterior and ventilation openings to prevent dust buildup, which can hinder cooling. Use a soft, dry cloth.
- Connection Checks: Annually inspect all electrical connections (PV, AC input, AC output, battery) for tightness and signs of corrosion. Loose connections can lead to overheating and poor performance.
- Battery Health: If using batteries, regularly check their condition according to the battery manufacturer's guidelines. Ensure proper ventilation around the battery bank.
- Environmental Conditions: Ensure the inverter is operating within its specified temperature and humidity ranges.
6. Troubleshooting
This section provides guidance on common issues you might encounter with your inverter. Refer to the LED indicators for initial diagnosis.
Common Faults and Warnings:
- Red FAULT LED (Solid On): Indicates a fault condition. This requires immediate attention. Check all connections, input/output voltages, and ensure no overloads.
- Red FAULT LED (Flashing): Indicates a warning condition. This suggests a potential issue that needs to be addressed before it escalates to a fault. Consult the inverter's detailed error codes (if available in the full manual) for specific warnings.
- No Output Power: Verify AC input, PV input, and battery connections. Check circuit breakers and fuses. Ensure the inverter is turned on.
- Low Battery Voltage: Ensure solar panels are producing sufficient power and batteries are charging. Check battery health.
- Overload Protection: The inverter will shut down if the connected load exceeds its capacity. Reduce the load and restart the inverter.
- Overheating Protection: Ensure proper ventilation around the inverter. Clear any obstructions from air vents.
Comprehensive Protections:
The inverter is equipped with multiple protection mechanisms:
- Overload Protection
- Overheating Protection
- High/Low Voltage Protection
- Battery Protection
- Short Circuit Protection
- Overcurrent Protection
- Anti Reverse Protection
- Power Failure Protection

If you are unable to resolve an issue, please contact customer support.
7. Warranty and Support
The SUMRY MPS V-MAX Hybrid Solar Inverter comes with standard certifications including CE, FCC, and RoHS, ensuring compliance with international safety and environmental standards.
For warranty information, technical support, or service inquiries, please refer to your purchase documentation or contact the SUMRY Factory Store directly through the platform where you purchased the product. Provide your model number and serial number for faster service.