1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the SUSWE SU800 series Variable Frequency Drive (VFD). The SU800 VFD is designed for precise speed control of three-phase motors, offering robust performance and advanced features for various industrial applications. Please read this manual thoroughly before using the product.

2. Safety Precautions
Before installation and operation, carefully read and understand all instructions and safety warnings. Failure to comply may result in personal injury, equipment damage, or improper operation. Always prioritize safety.
- Ensure power is disconnected before performing any wiring or maintenance.
- Only qualified personnel should install, operate, and maintain this equipment.
- Verify correct voltage and current ratings before connecting to power.
- Proper grounding is essential to prevent electric shock.
- Avoid touching internal components when power is applied.
3. Installation and Wiring
3.1. General Installation Guidelines
The VFD should be installed in a clean, dry, and well-ventilated area, away from direct sunlight, excessive dust, corrosive gases, and vibrations. Ensure adequate clearance for cooling.
3.2. Wiring Diagrams
Refer to the following diagrams for proper wiring connections. It is crucial to connect the power supply, motor, and ground wire correctly.

Terminal Marks:
- R, S, T/L, N: Power supply input terminals. Connect R, S, T for 3-phase 380V; connect L, N for single-phase 220VAC power supply.
- P+, PB: Brake electric resistance connection terminals.
- U, V, W: Frequency converter output terminals. Connect three-phase motor.
- Ground Symbol: Grounding terminals.
220V Wiring Diagram: Output L, N connected to power supply. Output U, V, W connected motor. Includes ground wire and circuit breaker.
380V Wiring Diagram: Enter R, S, T for power. Output U, V, W connected motor. Includes ground wire and circuit breaker.
Note: The control circuit wiring of all 800/900 series inverters is the same. The picture shows the three-phase 380V converter wiring diagram, indicating the main loop terminal, which represents the control loop terminal.

3.3. Detachable Smart Panel
The VFD features a detachable smart panel for flexible installation and operation. An external extension network cable is required to connect the panel remotely, allowing for convenient adjustment of working conditions.

4. Operating Instructions
4.1. Man-Machine Interactive Key Panel
The VFD's control panel allows for simultaneous monitoring of two groups of operating data, including speed, frequency, current, and voltage. The panel includes various keys and a speed control knob for intuitive operation.

- Display area: Shows operating data (e.g., frequency, current).
- Speed control knob: Adjusts motor speed.
- Run the key: Initiates motor operation.
- Stop/reset key: Stops motor operation and resets errors.
- Programming Key (PRG): Enters programming mode.
- Displacement key (<): Moves cursor or shifts digits during programming.
- Increment Key (▲): Increases values or navigates up.
- Decrement Key (▼): Decreases values or navigates down.
- Confirm key (ENTER): Confirms selections or parameter changes.
- Multi-function keys (MFK): Provides additional functions depending on the mode.
4.2. Inverter Demonstration Video
Watch this video for a practical demonstration of the inverter's functions, including panel testing, controlling positive and negative motor operation, and utilizing the removable panel feature.
5. Maintenance
Regular maintenance ensures the longevity and reliable operation of your VFD. Key aspects include proper cooling and protection against environmental factors.
5.1. Efficient Heat Dissipation
The VFD is equipped with a DC fan and an aluminum alloy radiator for quick and efficient heat dissipation. The intelligent start and stop function helps maintain optimal operating temperatures.

5.2. Environmental Protection
The inverter incorporates a three anti-paint process (polyurethane cool treatment) to enhance its stability and durability in harsh environments. This protects the internal components from moisture, dust, and corrosive substances.

5.3. Internal Component Quality
The VFD utilizes well-known brand components and a precise welding process (SMT) to ensure reliability and a longer service life. The industrial equipment anti-EMC power supply features a low-loss high-frequency transformer, overload protection, and wide voltage input function for stable operation.

6. Troubleshooting
This section provides general guidance for common issues. For specific error codes or complex problems, please refer to the detailed troubleshooting guide in the full product manual or contact customer support.
- No Power: Check power supply connections, circuit breaker, and input voltage.
- Motor Not Running: Verify motor wiring, VFD run command, and frequency settings.
- Overload Error: Check motor load, VFD current limits, and ensure proper motor sizing.
- Overvoltage/Undervoltage: Inspect input power quality and VFD voltage settings.
- Short Circuit Protection: The VFD is equipped with short circuit protection. If a short circuit occurs, the VFD will stop operation to prevent damage. Identify and resolve the short circuit before restarting.
7. Specifications
7.1. General Product Parameters
| Parameter | Value |
|---|---|
| Name | General purpose inverter |
| Power specifications | 0.75-45KW |
| Input Voltage | 220V/380V |
| Rated current | 1.5~320A |
| Input frequency | 50/60HZ |
| Protection level | IP20 |
| Temperature range | -20~+60°C |
| Cooling mode | Self-cooling fan |
| Use the motor | Suitable for fans and pumps |
| Product protection | 6 great protections |
| Scope of use | Woodworking machinery, food machinery, textile machinery, plastic machinery, CNC machine printing machinery, automation and other occasions requiring higher motor control |

7.2. Frequency Converter Series Index (SU800/SU900)
The following table outlines the specifications for various models within the SU800 and SU900 series, including power supply, rated input/output current, and adapted motor power.

This table provides detailed specifications for both single-phase (220V, 50Hz/60Hz) and three-phase (380V, 50Hz/60Hz) power supply models, including:
- Frequency Converter Mode (e.g., SU800-0R75G2, SU900-7R5G3)
- Power Supply (kVA)
- Rated Input Current (A)
- Rated Output Current (A)
- Adapted Motor (kW)
- Adapted Motor (HP)
7.3. External Unit Dimensions
Refer to the following diagrams for the dimensions of different external unit sizes (C1, C2, C3, C4, C5) suitable for various models.

Suitable for single-phase 220V models (SU800-0R75G2, SU800-1R5G2, SU800-2R2G2) and three-phase 380V models (SU800-0R75G3, SU900-0R75G3, SU800-1R5G3, SU900-1R5G3, SU800-2R2G3, SU900-2R2G3). Dimensions are provided for installation.

Suitable for single-phase 220V models (SU800-5R5G2, SU800-7R5G2) and three-phase 380V models (SU900-4R0G3, SU800-5R5G3, SU900-5R5G3, SU800-7R5G3, SU900-7R5G3). Dimensions are provided for installation.

Suitable for three-phase 380V models (SU900-7R5G3, SU900-11R0G3, SU900-15R0G3). Dimensions are provided for installation.

Suitable for three-phase 380V models (SU900-18R5G3, SU900-22R0G3). Dimensions are provided for installation.

Suitable for three-phase 380V models (SU900-18R5G3, SU900-22R0G3). Installation dimensions are provided.
8. Warranty and Support
8.1. Warranty Information
The SUSWE SU800 VFD comes with a one-year warranty from the date of purchase. This warranty covers manufacturing defects and ensures the product meets specified performance standards. Please retain your proof of purchase for warranty claims.
8.2. Certifications
The SUSWE SU800 VFD is certified to meet international quality and safety standards, including CE, FCC, and RoHS.

8.3. Customer Support
For technical assistance, troubleshooting, or warranty inquiries, please contact your local distributor or the SUSWE VFD Factory Store directly. Provide your product model number and a detailed description of the issue for efficient support.