1. Product Overview
This manual provides instructions for the 433 MHz Wireless Universal Remote Control Switch, model AKTR68-04B+AK-J027, manufactured by CENTURY AOKE. This system consists of a 4-channel RF relay receiver and a corresponding transmitter, designed for controlling various DC 12V appliances, garage doors, and gate systems wirelessly.

2. Specifications
2.1 Receiver (Model: AKTR68-04B)
| Feature | Specification |
|---|---|
| Working Voltage | DC 12V |
| Quiescent Current | < 6mA |
| Working Temperature | -40°C to +80°C |
| Receiver Sensitivity | > -105dBm |
| Working Frequency | 433MHz |
| Output Voltage | DC and AC (optional) |
| Output Current | < 8A |
| Max Load Current | 10A |
| Dimensions | 7.2 x 5.2 x 2.6 cm |
| Channels | 4 |
| Wireless Communication | RF |
| Support APP | No |
2.2 Transmitter (Remote Control)
| Feature | Specification |
|---|---|
| Buttons | 4 Buttons (A, B, C, D) |
| Working Voltage | DC 6V (2 x CR2016 batteries) |
| Operating Frequency | 433MHz |
| Remote Distance | 20-50 meters |
| Operating Current | 13 mAh |
| Encode | EV1527 code |
| Dimensions | 5.7 x 3.2 x 1.1 cm |
3. Setup and Wiring
Before connecting, ensure the power supply is disconnected. Incorrect wiring can damage the device or connected appliances.
3.1 DC 12V Appliance Wiring
Connect the DC 12V power supply to the receiver's U+ (positive) and U- (negative) terminals. Connect your DC 12V loads (e.g., lights, motors) to the corresponding relay output terminals (NOx, COMx, NCx) as shown in the diagram below. For typical switching applications, connect the load between the COM terminal and the NO (Normally Open) terminal for the load to be off when the relay is de-energized, and on when energized.

3.2 AC 220V Appliance Wiring
For controlling AC 220V appliances, the receiver itself still requires a DC 12V power supply. The relay contacts are rated for AC 250V 10A. Connect the AC 220V power source and loads to the relay output terminals (NOx, COMx, NCx) as depicted in the diagram. Ensure proper insulation and safety precautions when working with AC voltage.

3.3 Learning Method (Pairing Remote)
- Input DC 12V power to the receiver.
- Press the "LEARN" button on the receiver board. The LED indicator will turn ON.
- Loosen your finger from the "LEARN" button.
- Press any button (e.g., 'A') on the remote transmitter. The LED indicator on the receiver will flash three times, indicating successful learning.
- (Optional for some modes) Press another button (e.g., 'B') on the remote transmitter. The LED indicator will flash three times again, confirming the second button learning.

Video: Remote Control Pairing and Operation Demonstration
This video demonstrates the pairing process and how to operate the remote control switch in various modes.
4. Operating Modes
The working mode of the receiver is changed by adjusting the jumpers on the pins. Refer to Figure 5 for jumper positions.

- Momentary Mode: Jumper does not connect any two pins.
Operation: Press and hold a remote button to turn the relay ON; release the button to turn the relay OFF. - Toggle Mode: Jumper connects pin "3" and pin "4".
Operation: Press a remote button once to turn the relay ON; press the same button again to turn the relay OFF. - Latched Mode: Jumper connects pin "1" and pin "2".
Operation: Press one remote button (e.g., 'A') to turn the relay ON; press another remote button (e.g., 'B') to turn the relay OFF. - 2CH Momentary + 2CH Latched Mode: Jumper connects pins "1" & "2" AND pins "3" & "4".
Operation: This mode combines momentary and latched functions across different channels. Specific button assignments will depend on the learning process.
*Note: Delay modes (10s, 60s, 300s) mentioned in some descriptions are typically configured via the learning button on other receiver models. For AKTR68-04B, working modes are primarily set by jumpers.*
5. Maintenance
5.1 Clearing Codes (Unpairing Remote)
To clear all paired remote controls from the receiver's memory:
- Ensure the receiver is powered on.
- Press and hold the "LEARN" button on the receiver board for approximately 5 seconds.
- The LED indicator will turn OFF, then turn ON again, and finally flash seven times. This indicates that all stored codes have been successfully cleared.
- After clearing, any previously paired remote controls will no longer operate the receiver. You will need to re-pair them using the learning method if desired.
5.2 Transmitter Battery Replacement
The remote control transmitter uses two CR2016 coin cell batteries. If the remote's range decreases or it stops responding, the batteries may need replacement.
- Carefully open the remote control casing.
- Remove the old CR2016 batteries.
- Insert two new CR2016 batteries, ensuring correct polarity (+/-).
- Close the remote control casing securely.

6. Troubleshooting
- Receiver not responding to remote:
- Check if the remote control batteries are depleted. Replace if necessary.
- Ensure the remote is properly paired with the receiver. If not, perform the learning procedure (Section 3.3).
- Verify the remote is within the operating range (20-50 meters). Obstacles can reduce range.
- Confirm the receiver is receiving power (DC 12V).
- Appliance not turning ON/OFF:
- Check the wiring connections to the appliance and the receiver. Ensure they are secure and correct according to the wiring diagrams (Figures 2 & 3).
- Verify the appliance itself is functional and receiving power.
- Ensure the correct operating mode (Momentary, Toggle, Latched) is selected via the jumpers for your intended application.
- Receiver LED indicator not lighting up:
- Check the DC 12V power supply connection to the receiver.
- Ensure the power supply is providing the correct voltage.
- Remote control range is poor:
- Replace the remote control batteries.
- Ensure there are no major obstructions (e.g., thick walls, metal structures) between the remote and the receiver.
- Avoid sources of strong electromagnetic interference.
7. User Tips
- Versatile Application: This universal remote control system is highly versatile and can be used for various applications, including controlling lights, garage doors, gate openers, and other low-voltage power systems.
- RF Communication: The system utilizes RF (Radio Frequency) wireless communication, offering reliable control over a decent range, typically 20-50 meters, depending on environmental conditions.
- Mode Selection: Carefully select the appropriate operating mode (Momentary, Toggle, Latched) using the jumpers on the receiver board to match your specific application requirements. This is crucial for correct functionality.
- Power Considerations: Always ensure the receiver is powered by a stable DC 12V source. While the relays can switch AC loads, the receiver's control circuit requires DC 12V.

8. Warranty and Support
This product is certified with CE, FCC, and pse standards, ensuring compliance with relevant safety and quality regulations.
For technical support or inquiries, please refer to the seller's contact information or the platform's support channels. Keep your purchase records for any warranty claims.