MasTech MS2003A / MS2003B / MS2103A / MS2103B

Contents

MASTECH Digital Clamp Meter User Manual

Models: MS2003A, MS2003B, MS2103A, MS2103B Series

Professional Digital Multimeter for AC/DC Current, Voltage, Resistance, and More

1. Introduction

This manual provides detailed instructions for the safe and effective operation of your MASTECH Digital Clamp Meter. The MS2003A, MS2003B, MS2103A, and MS2103B series are professional-grade digital multimeters designed for accurate electrical measurements in various applications. Please read this manual thoroughly before use and keep it for future reference.

Important: Please carefully read the product description before placing your order. If there are any product parameters that may confuse you, you can proactively contact customer service for accurate answers. Please do not arrange your order without confirming the product parameters to avoid any disputes in the future.

2. Safety Information

To ensure safe operation and service of the meter, follow these safety precautions:

  • Always adhere to local and national safety codes.
  • Do not exceed the maximum input values for any function. The meter is rated CAT III 600V.
  • Use caution when working with voltages above 30V AC RMS, 42V peak, or 60V DC. These voltages pose a shock hazard.
  • Ensure the test leads are properly seated in the correct input jacks for the desired measurement.
  • Never apply voltage to the meter when the rotary switch is set to Resistance, Capacitance, Diode, or Continuity functions.
  • Disconnect the circuit power and discharge all high-voltage capacitors before measuring resistance, capacitance, or performing diode/continuity tests.
  • Do not operate the meter if it appears damaged or if the case is open.
  • Replace the battery immediately when the low battery indicator appears to ensure accurate readings.
  • Always use the Non-Contact Voltage (NCV) detection feature to verify if a circuit is live before making contact.

3. Package Contents

Upon unpacking, please verify that all items listed below are present and undamaged. Note: Batteries are NOT included with any MASTECH Clamp Meter.

  • Digital Clamp Meter (MS2003A, MS2003B, MS2103A, or MS2103B)
  • Carry Bag
  • Test Leads (Red and Black)
  • User Manual
  • Temperature Probe (Included with MS2003A, MS2003B, MS2103B models)
MS2103A Clamp Meter with carry bag, test leads, and manual
Package contents for MS2103A model.
MS2103B Clamp Meter with carry bag, test leads, manual, and temperature probe
Package contents for MS2103B model.

4. Product Overview

The MASTECH Digital Clamp Meter series features a compact design with a large LCD display and a rotary switch for function selection. Key components include:

  • Clamp Jaw: For non-contact AC/DC current measurement. Maximum jaw opening is 19mm.
  • Rotary Switch: Selects measurement functions (Voltage, Current, Resistance, Capacitance, Frequency, Diode, Continuity, NCV, Temperature).
  • LCD Display: Shows measurement readings, unit indicators, and special function icons.
  • Function Buttons: Include MAX/MIN, REL (Relative), SELECT, HOLD, Backlight, and NCV/Live.
  • Input Jacks: For connecting test leads for voltage, resistance, capacitance, diode, continuity, and temperature measurements.
Front view of MASTECH MS2003A Digital Clamp Meter showing display, rotary switch, and buttons
MASTECH MS2003A Digital Clamp Meter.
Front view of MASTECH MS2003B Digital Clamp Meter
MASTECH MS2003B Digital Clamp Meter.
Front view of MASTECH MS2103A Digital Clamp Meter
MASTECH MS2103A Digital Clamp Meter.
Front view of MASTECH MS2103B Digital Clamp Meter
MASTECH MS2103B Digital Clamp Meter.
Multiple views of the clamp meter showing front, side, and back
Various angles of the clamp meter.

5. Specifications

Below are the general and model-specific specifications for the MASTECH Digital Clamp Meter series.

General Specifications

  • Dimensions: 60mm x 178mm x 32mm
  • Weight: 165g
  • Display Type: Digital Only
  • Max Jaw Opening: 19mm
  • Input Impedance: ≥10MΩ
  • Safety Rating: CAT III 600V
  • Power: 2 x 1.5V AAA Batteries (Not Included)
  • Features: Auto Power Off, Data Hold, Backlight, Unit Display, Non-Contact Voltage (NCV) Detection / Live Wire Recognition, Diode / Continuity Test.

Model-Specific Features Comparison

Comparison table of features for MS2003A, MS2003B, MS2103A, MS2103B
Feature comparison across the MS2003/MS2103 series.
Model Feature Comparison
Feature MS2003A MS2003B MS2103A MS2103B
DC Current - - 200A 200A
AC Current 200A 200A 200A 200A
DC/AC Voltage 600V 600V 600V 600V
LOZ (Low Impedance) ✓ - ✓ -
Duty Cycle - ✓ - ✓
Temperature (°C/°F) ✓ ✓ - ✓

Detailed Measurement Specifications

Refer to the tables below for specific measurement ranges and accuracies for each model.

MS2003A / MS2003B Specifications

Specification table for MS2003A and MS2003B models
Detailed specifications for MS2003A and MS2003B.
MS2003A / MS2003B Measurement Ranges and Accuracy
Spec Range Accuracy
Resistance600Ω±(4.0%+10)
6KΩ, 60KΩ, 600KΩ, 6MΩ±(0.8%+5)
60MΩ±(2.0%+10)
DCV600mV±(0.7%+5)
6V, 60V, 600V±(0.8%+5)
ACV600mV±(1.0%+10)
6V, 60V, 600V±(1.0%+5)
V.F.C 600V±(4.0%+5)
ACA6000mA, 60A, 200A±(2.5%+10)
Frequency10Hz ~ 1KHz±(0.5%+2)
Capacitance10nF±(4.0%+25)
100nF ~ 100uF±(4.0%+15)
1mF ~ 60mF±(5.0%+25)
°C-20 °C ~ 0 °C±4 °C
0 °C ~ 400 °C±(2.0%+3)
400 °C ~ 1000 °C±(3.0%+3)
°F-4 °F ~ 50 °F±5 °F
50 °F ~ 750 °F±(2.0%+5)
750 °F ~ 1832 °F±(3.0%+5)

MS2103A Specifications

Specification table for MS2103A model
Detailed specifications for MS2103A.
MS2103A Measurement Ranges and Accuracy
Spec Range Accuracy
Resistance600Ω±(1.0%+10)
6KΩ, 60KΩ, 600KΩ, 6MΩ±(0.8%+5)
60MΩ±(2.0%+10)
DCV600mV±(0.7%+5)
6V, 60V, 600V±(0.8%+5)
ACV600mV±(1.0%+10)
6V, 60V, 600V±(1.0%+5)
ACA6mA, 60mA, 600mA±(2.5%+10)
60A, 200A±(1.5%+10)
DCA60A, 200A±(2.5%+10)
Frequency10Hz ~ 1MHz±(0.5%+2)
Capacitance60nF±(4.0%+25)
600nF ~ 600uF±(4.0%+15)
6mF ~ 60mF±(5.0%+25)

MS2103B Specifications

Specification table for MS2103B model
Detailed specifications for MS2103B.
MS2103B Measurement Ranges and Accuracy
Spec Range Accuracy
Resistance400Ω±(1.0%+10)
4KΩ, 40KΩ, 400KΩ, 4MΩ±(0.8%+5)
40MΩ±(2.0%+10)
DCV400mV±(0.7%+5)
4V, 40V, 400V, 600V±(0.8%+5)
ACV400mV±(1.0%+5)
4V, 40V, 400V, 600V±(1.0%+5)
ACA4A, 40A, 200A±(2.5%+10)
Frequency10Hz ~ 10MHz±(0.5%+2)
Capacitance40nF±(4.0%+25)
400nF ~ 400uF±(4.0%+15)
4mF±(5.0%+25)
°C-20 °C ~ 0 °C±4 °C
0 °C ~ 400 °C±(2.0%+3)
400 °C ~ 1000 °C±(3.0%+3)
°F-4 °F ~ 50 °F±5 °F
50 °F ~ 750 °F±(2.0%+5)
750 °F ~ 1832 °F±(3.0%+5)

6. Setup

Battery Installation

The clamp meter requires two (2) 1.5V AAA batteries for operation. Batteries are NOT included in the package.

  1. Ensure the meter is turned OFF.
  2. Locate the battery compartment cover on the back of the meter.
  3. Use a screwdriver to loosen the screw(s) on the battery cover.
  4. Remove the battery cover.
  5. Insert two 1.5V AAA batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
  6. Replace the battery cover and secure it with the screw(s).
Back view of the clamp meter showing the battery compartment
Battery compartment on the back of the meter.

7. Operating Instructions

This section outlines the basic operation for various measurement functions. Always ensure the meter is set to the correct function and range before making any measurements.

General Operation

  • Power On/Off: Rotate the function switch from OFF to any desired measurement function to power on. Rotate back to OFF to power off.
  • Auto Power Off: The meter will automatically power off after a period of inactivity to conserve battery life.
  • Backlight: Press the backlight button (often marked with a lightbulb icon) to illuminate the display in low-light conditions.
  • Data Hold: Press the HOLD button to freeze the current reading on the display. Press again to release.
  • MAX/MIN: For models with this feature, press the MAX/MIN button to capture the maximum or minimum reading during a measurement session.
  • REL (Relative Measurement): For models with this feature, press the REL button to store the current reading as a reference value and display subsequent measurements as a deviation from this reference.

Measurement Functions

  1. AC/DC Current Measurement (Clamp Jaw):
    • Rotate the function switch to the ACA (AC Current) or DCA (DC Current, for MS2103A/B) position.
    • Open the clamp jaw and enclose only one conductor of the circuit.
    • Read the current value on the display.
    Play video
    Watch video online
    Video demonstrating current measurement using the clamp jaw and showing the 19mm jaw opening.
  2. AC/DC Voltage Measurement:
    • Insert the red test lead into the VΩHz input jack and the black test lead into the COM jack.
    • Rotate the function switch to the ACV or DCV position.
    • Connect the test leads in parallel to the circuit or component to be measured.
    • Read the voltage value on the display.
  3. Resistance Measurement:
    • Ensure the circuit is de-energized.
    • Insert the red test lead into the VΩHz input jack and the black test lead into the COM jack.
    • Rotate the function switch to the Ω position.
    • Connect the test leads across the component to be measured.
    • Read the resistance value on the display.
  4. Capacitance Measurement:
    • Ensure the capacitor is discharged before measurement.
    • Insert the red test lead into the VΩHz input jack and the black test lead into the COM jack.
    • Rotate the function switch to the capacitance (often marked with a capacitor symbol) position.
    • Connect the test leads across the capacitor.
    • Read the capacitance value on the display.
    Clamp meter measuring resistance and capacitance on a circuit board
    Measuring resistance and capacitance on a circuit board.
  5. Frequency Measurement:
    • Insert the red test lead into the VΩHz input jack and the black test lead into the COM jack.
    • Rotate the function switch to the Hz position.
    • Connect the test leads to the signal source.
    • Read the frequency value on the display.
  6. Diode / Continuity Test:
    • Ensure the circuit is de-energized.
    • Insert the red test lead into the VΩHz input jack and the black test lead into the COM jack.
    • Rotate the function switch to the Diode/Continuity position (often marked with diode and buzzer symbols).
    • For continuity, connect leads across the circuit. A buzzer sounds for continuity.
    • For diode test, connect leads across the diode. The display shows the forward voltage drop.
  7. Non-Contact Voltage (NCV) Detection:
    • Rotate the function switch to the NCV position.
    • Bring the top of the meter near a live conductor. The meter will beep and an LED will flash if AC voltage is detected.
  8. Temperature Measurement (for models with °C/°F feature):
    • Insert the temperature probe into the appropriate input jacks (refer to meter markings).
    • Rotate the function switch to the °C/°F position.
    • Place the probe tip on or near the object whose temperature is to be measured.
    • Read the temperature on the display.

8. Maintenance

Cleaning

  • Wipe the meter with a damp cloth and mild detergent. Do not use abrasives or solvents.
  • Keep the input terminals free from dirt and moisture.

Battery Replacement

When the low battery indicator appears on the display, replace the batteries as described in the Setup section (Section 6).

Storage

If the meter is not to be used for an extended period, remove the batteries to prevent leakage and store the meter in a cool, dry place.

9. Troubleshooting

If your meter is not functioning correctly, check the following common issues:

  • No Display/Faint Display: Check battery installation and charge. Replace batteries if necessary.
  • Incorrect Readings:
    • Ensure the correct function and range are selected.
    • Check test lead connections; ensure they are fully inserted and not damaged.
    • Verify the circuit is de-energized for resistance, capacitance, and diode tests.
  • No Continuity Beep: Ensure the circuit is de-energized and the leads are making good contact.
  • NCV Not Detecting: Ensure the NCV function is selected and the meter is brought close enough to a live AC conductor.

If problems persist, contact customer support for assistance.

10. User Tips

  • Understand Your Meter's Capabilities: This series of clamp meters is designed for measuring AC/DC current (depending on model), AC/DC voltage, resistance, capacitance, frequency, diode, and continuity. For specialized measurements like AC leakage current (e.g., connecting phase and neutral simultaneously), a dedicated leakage clamp meter is typically required. Using a standard clamp meter for such purposes may yield inaccurate results or pose safety risks.
  • Check for Live Wires: Always use the NCV function first to quickly check for the presence of AC voltage before making direct contact with test leads.
  • Proper Lead Connection: For voltage, resistance, capacitance, diode, and continuity measurements, always use the test leads and ensure they are plugged into the correct VΩHz and COM jacks.
  • Single Conductor for Clamp: When measuring current with the clamp jaw, ensure only a single conductor passes through the jaw. Clamping around multiple conductors (e.g., both live and neutral) will result in a zero reading as the magnetic fields cancel out.

11. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the contact information provided by your retailer or visit the official MASTECH website. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.