SUMRY RS Series On/Off Grid Solar Inverter Instruction Manual

Models: RS4200 (4.2KVA) / RS7000 (7KVA)

1. Introduction

The SUMRY RS Series On/Off Grid Solar Inverter is a pure sine wave inverter designed for reliable power conversion in various applications. It features a large LCD screen for comprehensive information display, dual AC output, and intelligent battery charging capabilities. This inverter can operate with or without a battery, making it versatile for different solar power system configurations. It includes a built-in MPPT solar charger and offers optional WiFi remote monitoring for enhanced control and data analysis.

Front view of SUMRY RS Series Hybrid Solar Inverter with key specifications
Figure 1: SUMRY RS Series Hybrid Solar Inverter (RS4200/RS7000)

2. Safety Instructions

WARNING: ELECTRIC SHOCK HAZARD. All wiring must be performed by qualified personnel.

  • Before connecting the PV module, install a separate DC circuit breaker between the inverter and the PV module.
  • Ensure appropriate cable sizes are used for PV module connections to reduce the risk of injury and ensure system safety and efficient operation. Refer to the 'PV Connection' section for recommended cable sizes.
  • Always disconnect all power sources (PV, battery, utility) before performing any maintenance or wiring.
  • Do not attempt to repair the inverter yourself. Contact qualified service personnel.

3. Product Overview

3.1 Operation and Display Panel

The inverter features a front panel with an LCD screen and four function keys for indicating operation status and input/output power information.

Inverter front panel showing LCD display and function keys
Figure 2: Inverter Operation and Display

3.2 RGB Light Indicators

The inverter is equipped with RGB lights that display different colors to indicate its operational status:

  • Red Light: Fault State
  • Green Light: Inverter State (normal operation)
  • Blue Light: Utility State (powered by grid)
Diagram showing RGB light colors for Fault, Inverter, and Utility states
Figure 3: RGB Light Status Indicators

3.3 Rear Panel Connections

The rear panel provides various connection terminals for AC input, AC output, PV input, and battery connections.

Rear panel of the inverter showing AC input, AC main output, AC EPS output, PV input, and Battery input terminals
Figure 4: Rear Panel Connections

3.4 Communication Ports

The inverter includes two communication ports for BMS (Battery Management System) and optional WiFi connectivity.

Rear panel showing BMS and WiFi communication ports with pin definitions
Figure 5: BMS and WiFi Communication Ports

Note: For 485 communication with lithium battery BMS, only PACE and PYLONTECH's BMS are allowed.

4. Setup

4.1 Basic System Architecture

The SUMRY RS Series inverter can be integrated into a hybrid power system, connecting solar panels, external battery packs, and optionally a generator or utility grid to power home appliances.

Diagram of a Hybrid Power System showing connections between solar, generator, utility, battery, inverter, and loads
Figure 6: Hybrid Power System Diagram

4.2 Wiring Instructions

Carefully follow the wiring instructions provided in the video and diagrams. Ensure all connections are secure and correctly polarized.

Video 1: Inverter Wiring and Basic Operation Demonstration

4.3 PV Connection

Connect your PV modules to the inverter's PV input terminals. Observe the following guidelines:

  • Install a DC circuit breaker between the PV module and the inverter.
  • Ensure PV array open circuit voltage does not exceed the inverter's maximum limit.
  • PV module open circuit voltage should be higher than the minimum battery voltage.
Recommended Wire Gauge and Torque Value for PV Connection
ModelWire GaugeTorque Value
RS 22001 * 12 AWG1.2-1.6 Nm
RS 32001 * 10 AWG1.2-1.6 Nm
RS 42001 * 12 AWG1.2-1.6 Nm
RS 70001 * 12 AWG1.2-1.6 Nm
PV Module Selection Criteria
ModelRS 4200RS 7000
PV open circuit voltageMax 450Vdc
MPPT operating voltage range55Vdc ~ 430Vdc
PV Connection details including wire gauge table and PV module selection criteria
Figure 7: PV Connection Guidelines

4.4 Battery Connection

The inverter is compatible with various battery types, including Gel, Lithium-ion, AGM/Sealed, Flooded, and user-customized batteries. Ensure correct polarity when connecting batteries.

Diagram showing compatibility with multiple battery types: Flooded, Gel, Lithium-ion, AGM/Sealed, User custom Battery
Figure 8: Compatible Battery Types

4.5 Optional WiFi Module

For remote monitoring and control via a smartphone app (iOS and Android), an optional WiFi module can be connected to the inverter's communication port. This allows access to data, analysis, charts, and settings.

Image showing a smartphone with the monitoring app and the optional WiFi module connected to the inverter
Figure 9: WiFi Remote Monitoring Setup

5. Operating Instructions

5.1 Function Keys

The front panel features four function keys for navigating menus and adjusting settings:

Function KeyDescription
ESCExit setup mode
UPSkip to the previous setting
DOWNJump to the next setting
ENTERConfirm the selected mode or enter the set mode

5.2 Status Indicators

The LCD display and RGB lights provide visual feedback on the inverter's status:

Status Indicator IconIndicating Information
AC / INV (Solid On)Output is powered by utility in Line mode
AC / INV (Flashing)In battery mode, the output is powered by battery or PV
CHG (Solid On)The battery is fully charged
CHG (Flashing)The battery is charging
FAULT (Solid On)Fault occurs in the inverter
FAULT (Flashing)Warning condition occurs in the inverter
Tables detailing status indicator icons and function keys
Figure 10: Status Indicators and Function Keys

5.3 Internal Clock Function

The inverter includes an internal clock function that allows users to set AC charging times and load running times based on electricity prices, optimizing PV power generation data.

Diagrams illustrating internal clock function for PV power generation and battery SOC settings
Figure 11: Internal Clock and Battery SOC Settings

5.4 Lithium Battery Intelligent Charge Control

The intelligent charge control system adjusts the inverter's charging current based on the battery's state of charge (SOC) and other parameters. This helps to optimize battery utilization and extend its lifespan by preventing over-charge or over-temperature conditions.

6. Maintenance

  • Regularly inspect all wiring connections for tightness and corrosion.
  • Keep the inverter's ventilation openings clear of dust and debris to ensure proper cooling.
  • Clean the exterior of the inverter with a dry, soft cloth. Do not use liquid cleaners.
  • Periodically check the battery connections and ensure they are clean and secure.
  • Monitor the inverter's display for any fault codes or warnings and address them promptly.

7. Troubleshooting

  • Inverter not turning on: Check all power connections (PV, battery, utility) and ensure they are secure. Verify battery voltage is within the operating range.
  • No AC output: Check for fault indicators. Ensure AC output wiring is correct.
  • Battery not charging: Verify PV input is sufficient and PV connections are correct. Check battery type settings in the inverter.
  • Fault/Warning light active: Refer to the status indicator table (Section 5.2) for the meaning of the specific light pattern. If a persistent fault occurs, consult a qualified technician.
  • Inverter operating without battery: This inverter is designed to work without a battery, powering loads directly from the PV array.
  • Output Voltage: This model is designed for 220V/230VAC output. It does not support 110V/120V output.

8. Specifications

FeatureSpecification
Brand NameSUMRY
Model NumberHGX 4KW (RS4200), HGX 7KW (RS7000)
ApplicationCharger Controller, Voltage Controller
System TypeOn/Off Grid Hybrid Solar Inverter
Rated Power (RS4200)3800W (4.2KVA)
Rated Power (RS7000)6200W (7KVA)
DC Voltage (RS4200)24VDC
DC Voltage (RS7000)48VDC
AC Output Voltage220VAC / 230VAC Pure Sine Wave
Frequency Range50Hz/60Hz (Auto Sensing)
MPPT Operating Voltage Range55-450VDC
Maximum Solar Charging Current80A / 110A (Built-in)
Maximum Input Current20A
Communication PortsBMS, WiFi (optional)
CertificationsCE, FCC, RoHS
OriginMainland China
Package Dimensions58 x 45 x 20 cm
Package Weight10.0 kg

9. User Tips

  • The inverter can operate without a battery, directly powering loads from the PV array, which is useful for daytime power needs.
  • Ensure your battery type (GEL, LI, AGM, FLD, or custom) is correctly configured in the inverter settings for optimal charging and discharge management.
  • Consider purchasing the optional WiFi module for convenient remote monitoring and control of your solar system via a smartphone app.
  • When connecting lithium batteries via BMS, verify compatibility with PACE or PYLONTECH BMS systems as specified.

10. Warranty and Support

This product comes with a 1-year warranty. For technical support, service, or warranty claims, please contact your vendor or the SUMRY customer service department. Ensure you have your product model and serial number available when seeking support.

© 2024 SUMRY. All rights reserved.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.