PowMr POW-HVM3.2H-24V-N

Contents

PowMr Hybrid Solar Inverter User Manual

Models: POW-HVM3.2H-24V-N, POW-HVM2H-12V-N

1. Introduction

The PowMr Hybrid Solar Inverter is an all-in-one solution designed for off-grid solar systems. It integrates a pure sine wave inverter, an MPPT solar charger, and a battery charger into a single unit, offering a comprehensive power management system. This manual provides essential information for the safe and efficient operation of your inverter.

Video: Product unboxing and overview of key features including maximum output power, rated output voltage, maximum charging current, system voltage, MPPT voltage range, and maximum PV input.

2. Safety Information

Please read all instructions and cautionary markings on the unit and in this manual before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury.

  • Installation must be performed by qualified personnel.
  • Ensure all connections are tight to avoid loose connections that may cause overheating.
  • Do not disassemble the unit. There are no user-serviceable parts inside.
  • Keep the inverter away from flammable materials and ensure adequate ventilation.
  • Always disconnect all power sources (AC, DC, and PV) before performing any maintenance or wiring.
  • Wear appropriate personal protective equipment (PPE) during installation and maintenance.

3. Package Contents

Upon opening the package, you should find the following items:

  • PowMr Hybrid Solar Inverter
  • User Manual

4. Product Overview

The PowMr Hybrid Solar Inverter is designed for efficient energy conversion and reliable operation. It features a robust design with multiple protection modes to ensure system stability.

Key Features:

  • Pure Sine Wave Inverter Output
  • Maximum Power Point Tracking (MPPT) Solar Charger with 80A charging current
  • Rated Output Voltage: 230V
  • Wide MPPT Voltage Range: 30-400Vdc
  • Maximum PV Input Power: Up to 3000W
  • Compatible with various battery types: AGM, GEL, FLD, LI, SLD, USER
  • Intelligent Cooling Fan system
  • Real-Time Information Display
  • Multiple Protection Modes
  • Remote Monitoring and Control via the "SMARTESS" App (WiFi module sold separately)
  • Compatible with 95% of household and office appliances
Exploded view of the PowMr Hybrid Solar Inverter showing internal components and overall design.

Figure 1: Exploded view of the Hybrid Solar Inverter, highlighting its internal structure and fine craft design.

Diagram showing the intelligent cooling fan system within the inverter.

Figure 2: Intelligent Cooling Fan system, which adjusts fan speed based on ambient temperature for optimal performance.

Diagram illustrating the Smart Protection System with icons for various protection modes.

Figure 3: Smart Protection System, offering multiple protection modes including charge low/high temperature, discharge low/high temperature, overcurrent, undervoltage, short-circuit, solar panel reverse connection, battery overvoltage, over temperature, and overload protection.

Image of the inverter's LCD display showing real-time information.

Figure 4: Real-Time Display of Information Data, including mode, voltage, current, and error codes.

Diagram showing remote monitoring and control via the SMARTESS app.

Figure 5: Remote Monitoring and Control via the SMARTESS App. A WiFi module and GPRS data need to be purchased separately for this functionality.

Image showing the inverter compatible with various household and office appliances.

Figure 6: The inverter is compatible with 95% of household and office appliances, providing power for lamps, fans, refrigerators, air conditioners, coffee machines, etc.

5. Specifications

General Product Properties:

  • Model Number: POW-HVM3.2H-24V-N (and POW-HVM2H-12V-N)
  • Output Power: 1 - 200 KW
  • Output Type: SINGLE
  • Output Frequency: 50Hz/60Hz (Auto sensing)
  • Is Smart Device: Yes
  • Certification: CE, FCC, RoHS
  • Output Voltage Waveform: Pure Sine Wave
  • Nominal Input Voltage: 220V 230V 240V
  • PV Array MPPT Voltage Range: 30V - 400Vdc
  • Application: Home solar system
  • DC Input Voltage: 12V 24V
  • Max. PV Array Power: 2000W (for 1.6KW model), 3000W (for 3KW model)
  • Charging Current: MPPT 80A

Table 1: Line Mode Specifications

INVERTER MODEL1.0KW 12V1.5KW 24V24V 3.2KVA 3KW12V 2KVA 1.6KW
Input Voltage WaveformSinusoidal (Utility or Generator)
Nominal Input Voltage230Vac
Max AC Input Voltage300Vac
Nominal Input Frequency50Hz/60Hz (Auto detection)
Output Short Circuit ProtectionCircuit Breaker
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time10ms Typical (UPS); 20ms Typical (Appliances)

Table 2: Inverter Mode Specifications

INVERTER MODEL1.0KW 12V1.5KW 24V24V 3.2KVA 3KW12V 2KVA 1.6KW
Rated Output Power1000VA/1000W1500VA/1500W3200VA/3000W2000VA/1600W
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation230Vac±5%
Output Frequency50Hz
Peak Efficiency0.94
Overload Protection5s@≥150% Load; 10s@≤100%~150% Load
Surge Capacity2*rated power for 5 seconds
Nominal DC Input Voltage12Vdc24Vdc24Vdc12Vdc
Cold Start Voltage11.5Vdc23.0Vdc23.0Vdc11.5Vdc
High DC Recovery Voltage15.5Vdc31Vdc32Vdc14.0Vdc
High DC Cut-off Voltage16.0Vdc32Vdc33Vdc16.0Vdc
No Load Power Consumption<28W<28W<35W<25W

Table 3: Charge Mode Specifications

INVERTER MODEL1.0KW 12V1.5KW 24V24V 3.2KVA 3KW12V 2KVA 1.6KW
Utility Charging Mode
Charging Algorithm3-Step
AC Charging Current (Max)40Amp (V/p=230Vac)60Amp (@V /P=230vac)
Floating Charging Voltage13.5Vdc27Vdc27Vdc13.5Vdc
MPPT Solar Charging Mode
Max. PV Array Power600W1200W3000W2000W
PV Array MPPT Voltage Range20~150Vdc30~150Vdc30~400Vdc
Max. PV Array Open Circuit Voltage150Vdc400Vdc
Max (AC+Solar) Charging current80Amp

6. Setup

Proper installation is crucial for the safe and efficient operation of your inverter. Please follow these guidelines carefully.

6.1 Physical Connections

Identify the following connection points on your inverter:

  • AC IN: For connecting to the utility grid or generator.
  • AC OUT: For connecting to your household appliances/load.
  • BATTERY: For connecting to your battery bank (positive and negative terminals).
  • PV IN: For connecting to your solar panel array (positive and negative terminals).
  • GROUND: For proper grounding of the unit.
  • COMM: Communication port (e.g., for WiFi module).
Rear view of the inverter showing AC IN, AC OUT, Battery, PV IN, and Ground connections.

Figure 7: Rear view of the inverter, detailing the AC input/output, battery, PV input, and grounding terminals.

Bottom view of the inverter showing cooling fans and battery connections.

Figure 8: Bottom view of the inverter, showing cooling fans and battery connections.

Side view of the inverter showing the COMM port.

Figure 9: Side view of the inverter, highlighting the COMM port for communication modules.

6.2 Wiring Diagram and Priority Settings

The inverter allows for configurable charging source priority and output source priority to optimize your energy usage.

Wiring diagram showing 4 charger source priorities and 3 output source priorities.

Figure 10: Wiring diagram illustrating the various charging and output priority configurations.

Charger Source Priority (4 Options):

  1. Utility/AC Power: Charge battery first from AC power.
  2. Solar Power: Charge battery first from solar power.
  3. Solar + Utility: Charge battery at the same time from both solar and utility.
  4. ONLY Solar: Charge battery only from solar power.

Output Source Priority (3 Options):

  1. Utility Source: Load powered first by utility.
  2. Solar Power: Load powered first by solar.
  3. Solar + Battery: Load powered at the same time by solar and battery.

7. Operating Instructions

The inverter features an LCD display and control buttons for easy operation and monitoring.

7.1 LCD Display and Buttons

Front view of the inverter showing the LCD display and control buttons.

Figure 11: Front view of the inverter with LCD display and control buttons (ESC, UP, DOWN, ENTER).

Use the ESC, UP, DOWN, and ENTER buttons to navigate through the menus and adjust settings on the LCD display. The display provides real-time information on operating mode, voltage, current, and any error codes.

7.2 Powering On/Off

  • To Power On: Ensure all connections are secure. Turn on the DC breaker for the battery, then the AC input breaker (if connected to utility), and finally the PV input breaker (if solar panels are connected). Press the power button on the side of the inverter.
  • To Power Off: Reverse the power-on sequence. First, turn off the AC output breaker, then the PV input breaker, followed by the AC input breaker, and finally the DC breaker for the battery. Press and hold the power button until the unit shuts down.
Side view of the inverter showing the power switch.

Figure 12: Side view of the inverter, showing the main power switch.

8. Maintenance

Regular maintenance helps ensure the longevity and optimal performance of your PowMr Hybrid Solar Inverter.

  • Cleaning: Keep the inverter clean and free from dust. Use a dry cloth to wipe the exterior. Do not use liquid cleaners.
  • Ventilation: Ensure that the ventilation openings are not blocked. Proper airflow is essential for cooling.
  • Connections: Periodically check all electrical connections (AC, DC, PV, Battery) to ensure they are tight and free from corrosion.
  • Battery Health: Monitor your battery bank's health according to the battery manufacturer's recommendations.
  • Firmware Updates: Check the manufacturer's website for any available firmware updates for your model.

9. Troubleshooting

If you encounter issues with your inverter, refer to the following general troubleshooting steps. For specific error codes or persistent problems, contact customer support.

  • No Power: Check all power connections (AC input, battery, PV input). Ensure the main power switch is ON.
  • No Output: Verify that the AC output breaker is engaged and that the load is within the inverter's capacity. Check for any overload or short-circuit protection warnings on the display.
  • Charging Issues: Ensure solar panels are receiving adequate sunlight and are correctly connected. Check battery connections and health. Verify charging mode settings.
  • Error Codes: Refer to the LCD display for any error codes. Consult the full user manual (if available) or contact support with the specific code.

10. User Tips

  • PV Input Current: Always verify that your solar panel array's specifications, especially the maximum PV input current and voltage, are compatible with your inverter model to prevent damage. For example, ensure the PV charge current does not exceed the inverter's maximum rating (e.g., 80A).
  • Battery Compatibility: The inverter supports various battery types. Ensure you select the correct battery type in the inverter settings for optimal charging and discharge performance.
  • System Sizing: Properly size your solar array and battery bank to match your energy consumption and the inverter's capabilities for efficient operation.

11. Warranty and Support