1. Introduction
The PowMr Hybrid Solar Inverter is an all-in-one solution designed for off-grid solar systems. It integrates a pure sine wave inverter, an MPPT solar charger, and a battery charger into a single unit, offering a comprehensive power management system. This manual provides essential information for the safe and efficient operation of your inverter.
Video: Product unboxing and overview of key features including maximum output power, rated output voltage, maximum charging current, system voltage, MPPT voltage range, and maximum PV input.
2. Safety Information
Please read all instructions and cautionary markings on the unit and in this manual before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury.
- Installation must be performed by qualified personnel.
- Ensure all connections are tight to avoid loose connections that may cause overheating.
- Do not disassemble the unit. There are no user-serviceable parts inside.
- Keep the inverter away from flammable materials and ensure adequate ventilation.
- Always disconnect all power sources (AC, DC, and PV) before performing any maintenance or wiring.
- Wear appropriate personal protective equipment (PPE) during installation and maintenance.
3. Package Contents
Upon opening the package, you should find the following items:
- PowMr Hybrid Solar Inverter
- User Manual
4. Product Overview
The PowMr Hybrid Solar Inverter is designed for efficient energy conversion and reliable operation. It features a robust design with multiple protection modes to ensure system stability.
Key Features:
- Pure Sine Wave Inverter Output
- Maximum Power Point Tracking (MPPT) Solar Charger with 80A charging current
- Rated Output Voltage: 230V
- Wide MPPT Voltage Range: 30-400Vdc
- Maximum PV Input Power: Up to 3000W
- Compatible with various battery types: AGM, GEL, FLD, LI, SLD, USER
- Intelligent Cooling Fan system
- Real-Time Information Display
- Multiple Protection Modes
- Remote Monitoring and Control via the "SMARTESS" App (WiFi module sold separately)
- Compatible with 95% of household and office appliances

Figure 1: Exploded view of the Hybrid Solar Inverter, highlighting its internal structure and fine craft design.

Figure 2: Intelligent Cooling Fan system, which adjusts fan speed based on ambient temperature for optimal performance.

Figure 3: Smart Protection System, offering multiple protection modes including charge low/high temperature, discharge low/high temperature, overcurrent, undervoltage, short-circuit, solar panel reverse connection, battery overvoltage, over temperature, and overload protection.

Figure 4: Real-Time Display of Information Data, including mode, voltage, current, and error codes.

Figure 5: Remote Monitoring and Control via the SMARTESS App. A WiFi module and GPRS data need to be purchased separately for this functionality.

Figure 6: The inverter is compatible with 95% of household and office appliances, providing power for lamps, fans, refrigerators, air conditioners, coffee machines, etc.
5. Specifications
General Product Properties:
- Model Number: POW-HVM3.2H-24V-N (and POW-HVM2H-12V-N)
- Output Power: 1 - 200 KW
- Output Type: SINGLE
- Output Frequency: 50Hz/60Hz (Auto sensing)
- Is Smart Device: Yes
- Certification: CE, FCC, RoHS
- Output Voltage Waveform: Pure Sine Wave
- Nominal Input Voltage: 220V 230V 240V
- PV Array MPPT Voltage Range: 30V - 400Vdc
- Application: Home solar system
- DC Input Voltage: 12V 24V
- Max. PV Array Power: 2000W (for 1.6KW model), 3000W (for 3KW model)
- Charging Current: MPPT 80A
Table 1: Line Mode Specifications
| INVERTER MODEL | 1.0KW 12V | 1.5KW 24V | 24V 3.2KVA 3KW | 12V 2KVA 1.6KW |
|---|---|---|---|---|
| Input Voltage Waveform | Sinusoidal (Utility or Generator) | |||
| Nominal Input Voltage | 230Vac | |||
| Max AC Input Voltage | 300Vac | |||
| Nominal Input Frequency | 50Hz/60Hz (Auto detection) | |||
| Output Short Circuit Protection | Circuit Breaker | |||
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | |||
| Transfer Time | 10ms Typical (UPS); 20ms Typical (Appliances) | |||
Table 2: Inverter Mode Specifications
| INVERTER MODEL | 1.0KW 12V | 1.5KW 24V | 24V 3.2KVA 3KW | 12V 2KVA 1.6KW |
|---|---|---|---|---|
| Rated Output Power | 1000VA/1000W | 1500VA/1500W | 3200VA/3000W | 2000VA/1600W |
| Output Voltage Waveform | Pure Sine Wave | |||
| Output Voltage Regulation | 230Vac±5% | |||
| Output Frequency | 50Hz | |||
| Peak Efficiency | 0.94 | |||
| Overload Protection | 5s@≥150% Load; 10s@≤100%~150% Load | |||
| Surge Capacity | 2*rated power for 5 seconds | |||
| Nominal DC Input Voltage | 12Vdc | 24Vdc | 24Vdc | 12Vdc |
| Cold Start Voltage | 11.5Vdc | 23.0Vdc | 23.0Vdc | 11.5Vdc |
| High DC Recovery Voltage | 15.5Vdc | 31Vdc | 32Vdc | 14.0Vdc |
| High DC Cut-off Voltage | 16.0Vdc | 32Vdc | 33Vdc | 16.0Vdc |
| No Load Power Consumption | <28W | <28W | <35W | <25W |
Table 3: Charge Mode Specifications
| INVERTER MODEL | 1.0KW 12V | 1.5KW 24V | 24V 3.2KVA 3KW | 12V 2KVA 1.6KW |
|---|---|---|---|---|
| Utility Charging Mode | ||||
| Charging Algorithm | 3-Step | |||
| AC Charging Current (Max) | 40Amp (V/p=230Vac) | 60Amp (@V /P=230vac) | ||
| Floating Charging Voltage | 13.5Vdc | 27Vdc | 27Vdc | 13.5Vdc |
| MPPT Solar Charging Mode | ||||
| Max. PV Array Power | 600W | 1200W | 3000W | 2000W |
| PV Array MPPT Voltage Range | 20~150Vdc | 30~150Vdc | 30~400Vdc | |
| Max. PV Array Open Circuit Voltage | 150Vdc | 400Vdc | ||
| Max (AC+Solar) Charging current | 80Amp | |||
6. Setup
Proper installation is crucial for the safe and efficient operation of your inverter. Please follow these guidelines carefully.
6.1 Physical Connections
Identify the following connection points on your inverter:
- AC IN: For connecting to the utility grid or generator.
- AC OUT: For connecting to your household appliances/load.
- BATTERY: For connecting to your battery bank (positive and negative terminals).
- PV IN: For connecting to your solar panel array (positive and negative terminals).
- GROUND: For proper grounding of the unit.
- COMM: Communication port (e.g., for WiFi module).

Figure 7: Rear view of the inverter, detailing the AC input/output, battery, PV input, and grounding terminals.

Figure 8: Bottom view of the inverter, showing cooling fans and battery connections.

Figure 9: Side view of the inverter, highlighting the COMM port for communication modules.
6.2 Wiring Diagram and Priority Settings
The inverter allows for configurable charging source priority and output source priority to optimize your energy usage.

Figure 10: Wiring diagram illustrating the various charging and output priority configurations.
Charger Source Priority (4 Options):
- Utility/AC Power: Charge battery first from AC power.
- Solar Power: Charge battery first from solar power.
- Solar + Utility: Charge battery at the same time from both solar and utility.
- ONLY Solar: Charge battery only from solar power.
Output Source Priority (3 Options):
- Utility Source: Load powered first by utility.
- Solar Power: Load powered first by solar.
- Solar + Battery: Load powered at the same time by solar and battery.
7. Operating Instructions
The inverter features an LCD display and control buttons for easy operation and monitoring.
7.1 LCD Display and Buttons

Figure 11: Front view of the inverter with LCD display and control buttons (ESC, UP, DOWN, ENTER).
Use the ESC, UP, DOWN, and ENTER buttons to navigate through the menus and adjust settings on the LCD display. The display provides real-time information on operating mode, voltage, current, and any error codes.
7.2 Powering On/Off
- To Power On: Ensure all connections are secure. Turn on the DC breaker for the battery, then the AC input breaker (if connected to utility), and finally the PV input breaker (if solar panels are connected). Press the power button on the side of the inverter.
- To Power Off: Reverse the power-on sequence. First, turn off the AC output breaker, then the PV input breaker, followed by the AC input breaker, and finally the DC breaker for the battery. Press and hold the power button until the unit shuts down.

Figure 12: Side view of the inverter, showing the main power switch.
8. Maintenance
Regular maintenance helps ensure the longevity and optimal performance of your PowMr Hybrid Solar Inverter.
- Cleaning: Keep the inverter clean and free from dust. Use a dry cloth to wipe the exterior. Do not use liquid cleaners.
- Ventilation: Ensure that the ventilation openings are not blocked. Proper airflow is essential for cooling.
- Connections: Periodically check all electrical connections (AC, DC, PV, Battery) to ensure they are tight and free from corrosion.
- Battery Health: Monitor your battery bank's health according to the battery manufacturer's recommendations.
- Firmware Updates: Check the manufacturer's website for any available firmware updates for your model.
9. Troubleshooting
If you encounter issues with your inverter, refer to the following general troubleshooting steps. For specific error codes or persistent problems, contact customer support.
- No Power: Check all power connections (AC input, battery, PV input). Ensure the main power switch is ON.
- No Output: Verify that the AC output breaker is engaged and that the load is within the inverter's capacity. Check for any overload or short-circuit protection warnings on the display.
- Charging Issues: Ensure solar panels are receiving adequate sunlight and are correctly connected. Check battery connections and health. Verify charging mode settings.
- Error Codes: Refer to the LCD display for any error codes. Consult the full user manual (if available) or contact support with the specific code.
10. User Tips
- PV Input Current: Always verify that your solar panel array's specifications, especially the maximum PV input current and voltage, are compatible with your inverter model to prevent damage. For example, ensure the PV charge current does not exceed the inverter's maximum rating (e.g., 80A).
- Battery Compatibility: The inverter supports various battery types. Ensure you select the correct battery type in the inverter settings for optimal charging and discharge performance.
- System Sizing: Properly size your solar array and battery bank to match your energy consumption and the inverter's capabilities for efficient operation.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please contact PowMr customer service or refer to the official PowMr website. Keep your purchase receipt as proof of purchase for warranty claims.