WinAPEX 268B

Contents

WinAPEX 268B Intelligent AC-DC Leakage Current Meter User Manual

Model: 268B

1. Introduction

The WinAPEX 268B is an intelligent, multi-function AC-DC leakage current meter designed for both home and professional applications. It features a large LCD screen, intelligent recognition of measurement types, and various measurement capabilities including AC/DC voltage, AC/DC current, resistance, capacitance, frequency, temperature, diode, continuity, NCV, and FireWire detection. Its compact design and built-in Type-C rechargeable battery make it convenient for portable use.

WinAPEX 268B Leakage Current Clamp Meter front view
Figure 1: Front view of the WinAPEX 268B Leakage Current Clamp Meter.

2. Safety & Warnings

Warning!

  • This product is only for adult use.
  • Please keep out of reach of children and pets to avoid accidental injury or ingestion.
  • Check if the installation is correct before use.
  • If there is abnormal noise or equipment error after installation, stop using the device immediately.
  • Follow all instructions for proper use; misuse may cause harm.
  • Store in a dry and shady place, away from high temperatures, humidity, and direct sunlight.
Back view of WinAPEX 268B showing battery compartment and safety warnings
Figure 2: Back view of the device with safety warnings and serial number.

3. Package Contents

The package includes the following items:

  • 1 x WinAPEX 268B Leakage Current Clamp Meter
  • 1 Pair Test Leads
  • 1 x Thermocouple
  • 1 x Type-C Cable

4. Setup

4.1 Initial Inspection

Before first use, ensure the product is free from any damage. Check all components for proper connection and integrity.

4.2 Charging the Device

The WinAPEX 268B features a built-in battery that supports Type-C charging. Connect the provided Type-C cable to the device and a suitable power source to charge. A full charge provides approximately 20 hours of continuous battery life.

4.3 Connecting Test Leads and Thermocouple

For voltage, resistance, capacitance, diode, and continuity measurements, connect the test leads to the appropriate input jacks on the meter. For temperature measurements, connect the thermocouple.

5. Operating Instructions

5.1 Functional Overview

The WinAPEX 268B offers a wide range of functions, intelligently recognized for ease of use. The functional display includes:

Functional display icons for WinAPEX 268B including AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Temperature, Diode/Beep, Frequency, NCV, Live, Leakage Detection, Screen Rotation, Clear Capacitance, Charging USB, Flashlight, Brightness Adjustable, Automatic Shutdown
Figure 3: Overview of the meter's functional display icons.
  • V (AC/DC Voltage): Measures AC and DC voltage.
  • A (AC/DC Current): Measures AC and DC current.
  • Ω (Resistance): Measures electrical resistance.
  • ╂ (Capacitance): Measures capacitance.
  • °C/°F (Temperature): Measures temperature.
  • Diode/Beep: Diode test and continuity buzzer.
  • Hz (Frequency): Measures frequency.
  • NCV (Non-contact measurement): Non-contact voltage detection.
  • LIVE (Fire line measurement): Live wire detection.
  • Leakage detection: Detects AC and DC leakage current.
  • Screen Rotation: Rotates the display for two-handed operation.
  • ZERO (Clear capacitance): Zeros out capacitance readings.
  • Charging USB: Indicates USB charging capability.
  • Flashlight: Built-in flashlight function.
  • Brightness adjustable: Screen brightness can be adjusted.
  • Automatic shutdown: Device powers off automatically after a period of inactivity.

5.2 Intelligent Recognition

The meter intelligently recognizes common measurement types such as DC Voltage, AC Voltage, Buzzer (continuity), and Resistance, simplifying operation.

Intelligent Recognition display for DC Voltage, AC Voltage, Buzzer, and Resistance
Figure 4: Examples of intelligent recognition for various measurements.

5.3 Leakage Current Measurement

To detect AC and DC leakage current, simply clamp the meter around the wire. There is no need to separate the wires, allowing for quick assessment of circuit safety.

The DC current resolution is 1mA, and the AC current resolution is 0.1mA, enabling detailed measurement of small currents, including car starting currents.

5.4 Non-Contact Voltage (NCV) Test

When AC voltage is nearby, the buzzer will sound continuously, and the LCD will display different segments according to the signal strength. If "EF" is displayed, it means no signal is detected.

NCV Non-contact Voltage Test in progress, showing the meter detecting voltage near a power outlet
Figure 5: Performing a Non-Contact Voltage (NCV) test.

5.5 Screen and Display

The meter features a clear, large 17mm high character LCD screen. The brightness can be adjusted to 5 levels to suit various external environments.

Clear Large Display of the WinAPEX 268B with brightness adjustment levels indicated
Figure 6: The clear large display with adjustable brightness.

Screen Rotation: Long press the designated button to rotate the screen 180 degrees, allowing for free operation with both hands and improving the field of vision.

Screen Rotation feature demonstration, showing the display rotating 180 degrees
Figure 7: Demonstration of the one-key screen rotation feature.

6. Specifications

Measurement Type Range
AC Voltage 6V / 60V / 600V / 750V
DC Voltage 6V / 60V / 600V / 1000V
AC Current 600 mA / 6 A / 60 A
DC Current 6A / 60A
NCV Test Support Non-Contact Voltage Test
Temperature (-20-1000)°C / (0-1832)°F
Capacitance 6 nF / 60 nF / 600 nF / 6 µF / 60 µF / 600 µF / 6 mF / 60 mF
Resistance 600Ω / 6kΩ / 60kΩ / 600kΩ / 6mΩ / 60mΩ
Frequency 6Hz / 60Hz / 600Hz / 6KHz / 60KHz / 600KHz / 6MHz / 10MHz
Diode Support
Continuity Support
FireWire Support

Dimensions: Approximately 17 x 5.5 cm

Material: ABS

Battery: Built-in, Type-C rechargeable (20 hours continuous battery life)

7. Maintenance

7.1 General Care

After each use, store the product in a dry place. Keep it away from children, high temperatures, humidity, and direct sunlight to ensure its longevity and proper functioning.

7.2 Cleaning

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents that could damage the casing or display.

7.3 Battery Replacement / Opening Case

WARNING: To avoid electrical shock, remove test leads before replacing the battery or opening the case.

8. Troubleshooting

  • Device not turning on: Ensure the battery is charged. Connect the Type-C cable and charge the device.
  • Abnormal noise or equipment error: Stop using the device immediately and check for any visible damage or incorrect connections. If the issue persists, contact support.
  • Inaccurate readings: Ensure test leads are properly connected and the correct measurement mode is selected. For leakage current, ensure the clamp is correctly positioned around the wire.
  • Display issues: Adjust the screen brightness using the dedicated function. If the screen is unresponsive or shows incorrect characters, try restarting the device.

9. User Tips

  • Utilize the screen rotation feature for comfortable viewing and operation in various positions, especially when working in tight spaces or with two hands.
  • Take advantage of the intelligent recognition feature to quickly switch between common measurement types without manual selection.
  • For precise leakage current measurements, ensure the clamp jaws are fully closed around the conductor.
  • The built-in flashlight can be very useful when working in dimly lit environments.

10. Warranty & Support

For warranty information or technical support, please contact the manufacturer or your local distributor. Refer to the manufacturer's contact details provided below:

Manufacturer: Shenzhen Zhifu Technology Co., Ltd.

Address: 5B52Y, Floor 5, Building 210, Tairan Science and Technology Park, Tairan 4th Road, Tianan Community, Shatou Street, Futian District, Shenzhen Code: 518000

EU Authorized Representative: Prolinx GmbH

Address: Brehmstr.56, eu@eulinx.eu/49 2113105 4698

A comprehensive user manual in PDF format is available for download. View User Manual (PDF)

© 2023 WinAPEX. All rights reserved.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.