1. Introduction
The WinAPEX 268B is an intelligent, multi-function AC-DC leakage current meter designed for both home and professional applications. It features a large LCD screen, intelligent recognition of measurement types, and various measurement capabilities including AC/DC voltage, AC/DC current, resistance, capacitance, frequency, temperature, diode, continuity, NCV, and FireWire detection. Its compact design and built-in Type-C rechargeable battery make it convenient for portable use.
2. Safety & Warnings
Warning!
- This product is only for adult use.
- Please keep out of reach of children and pets to avoid accidental injury or ingestion.
- Check if the installation is correct before use.
- If there is abnormal noise or equipment error after installation, stop using the device immediately.
- Follow all instructions for proper use; misuse may cause harm.
- Store in a dry and shady place, away from high temperatures, humidity, and direct sunlight.
3. Package Contents
The package includes the following items:
- 1 x WinAPEX 268B Leakage Current Clamp Meter
- 1 Pair Test Leads
- 1 x Thermocouple
- 1 x Type-C Cable
4. Setup
4.1 Initial Inspection
Before first use, ensure the product is free from any damage. Check all components for proper connection and integrity.
4.2 Charging the Device
The WinAPEX 268B features a built-in battery that supports Type-C charging. Connect the provided Type-C cable to the device and a suitable power source to charge. A full charge provides approximately 20 hours of continuous battery life.
4.3 Connecting Test Leads and Thermocouple
For voltage, resistance, capacitance, diode, and continuity measurements, connect the test leads to the appropriate input jacks on the meter. For temperature measurements, connect the thermocouple.
5. Operating Instructions
5.1 Functional Overview
The WinAPEX 268B offers a wide range of functions, intelligently recognized for ease of use. The functional display includes:
- V (AC/DC Voltage): Measures AC and DC voltage.
- A (AC/DC Current): Measures AC and DC current.
- Ω (Resistance): Measures electrical resistance.
- ╂ (Capacitance): Measures capacitance.
- °C/°F (Temperature): Measures temperature.
- Diode/Beep: Diode test and continuity buzzer.
- Hz (Frequency): Measures frequency.
- NCV (Non-contact measurement): Non-contact voltage detection.
- LIVE (Fire line measurement): Live wire detection.
- Leakage detection: Detects AC and DC leakage current.
- Screen Rotation: Rotates the display for two-handed operation.
- ZERO (Clear capacitance): Zeros out capacitance readings.
- Charging USB: Indicates USB charging capability.
- Flashlight: Built-in flashlight function.
- Brightness adjustable: Screen brightness can be adjusted.
- Automatic shutdown: Device powers off automatically after a period of inactivity.
5.2 Intelligent Recognition
The meter intelligently recognizes common measurement types such as DC Voltage, AC Voltage, Buzzer (continuity), and Resistance, simplifying operation.
5.3 Leakage Current Measurement
To detect AC and DC leakage current, simply clamp the meter around the wire. There is no need to separate the wires, allowing for quick assessment of circuit safety.
The DC current resolution is 1mA, and the AC current resolution is 0.1mA, enabling detailed measurement of small currents, including car starting currents.
5.4 Non-Contact Voltage (NCV) Test
When AC voltage is nearby, the buzzer will sound continuously, and the LCD will display different segments according to the signal strength. If "EF" is displayed, it means no signal is detected.
5.5 Screen and Display
The meter features a clear, large 17mm high character LCD screen. The brightness can be adjusted to 5 levels to suit various external environments.
Screen Rotation: Long press the designated button to rotate the screen 180 degrees, allowing for free operation with both hands and improving the field of vision.
6. Specifications
| Measurement Type | Range |
|---|---|
| AC Voltage | 6V / 60V / 600V / 750V |
| DC Voltage | 6V / 60V / 600V / 1000V |
| AC Current | 600 mA / 6 A / 60 A |
| DC Current | 6A / 60A |
| NCV Test | Support Non-Contact Voltage Test |
| Temperature | (-20-1000)°C / (0-1832)°F |
| Capacitance | 6 nF / 60 nF / 600 nF / 6 µF / 60 µF / 600 µF / 6 mF / 60 mF |
| Resistance | 600Ω / 6kΩ / 60kΩ / 600kΩ / 6mΩ / 60mΩ |
| Frequency | 6Hz / 60Hz / 600Hz / 6KHz / 60KHz / 600KHz / 6MHz / 10MHz |
| Diode | Support |
| Continuity | Support |
| FireWire | Support |
Dimensions: Approximately 17 x 5.5 cm
Material: ABS
Battery: Built-in, Type-C rechargeable (20 hours continuous battery life)
7. Maintenance
7.1 General Care
After each use, store the product in a dry place. Keep it away from children, high temperatures, humidity, and direct sunlight to ensure its longevity and proper functioning.
7.2 Cleaning
Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents that could damage the casing or display.
7.3 Battery Replacement / Opening Case
WARNING: To avoid electrical shock, remove test leads before replacing the battery or opening the case.
8. Troubleshooting
- Device not turning on: Ensure the battery is charged. Connect the Type-C cable and charge the device.
- Abnormal noise or equipment error: Stop using the device immediately and check for any visible damage or incorrect connections. If the issue persists, contact support.
- Inaccurate readings: Ensure test leads are properly connected and the correct measurement mode is selected. For leakage current, ensure the clamp is correctly positioned around the wire.
- Display issues: Adjust the screen brightness using the dedicated function. If the screen is unresponsive or shows incorrect characters, try restarting the device.
9. User Tips
- Utilize the screen rotation feature for comfortable viewing and operation in various positions, especially when working in tight spaces or with two hands.
- Take advantage of the intelligent recognition feature to quickly switch between common measurement types without manual selection.
- For precise leakage current measurements, ensure the clamp jaws are fully closed around the conductor.
- The built-in flashlight can be very useful when working in dimly lit environments.
10. Warranty & Support
For warranty information or technical support, please contact the manufacturer or your local distributor. Refer to the manufacturer's contact details provided below:
Manufacturer: Shenzhen Zhifu Technology Co., Ltd.
Address: 5B52Y, Floor 5, Building 210, Tairan Science and Technology Park, Tairan 4th Road, Tianan Community, Shatou Street, Futian District, Shenzhen Code: 518000
EU Authorized Representative: Prolinx GmbH
Address: Brehmstr.56, eu@eulinx.eu/49 2113105 4698
A comprehensive user manual in PDF format is available for download. View User Manual (PDF)