1. Introduction and Key Features
The Daxtromn 10.2KW 2XMPPT On/Off Grid Solar Hybrid Inverter is a versatile power solution designed for both grid-tied and off-grid solar applications. It features a pure sine wave output, ensuring compatibility with sensitive electronics, and a high-efficiency design to maximize energy utilization.
Key Features:
- Pure sine wave solar inverter (on/off Grid capability)
- Output power factor of 1.0
- WIFI connectivity for monitoring via iOS and Android applications
- Ability to operate without a connected battery
- One-key restoration to factory settings for ease of use
- Built-in automatic activation for Lithium batteries
- Integrated 160A MPPT solar charger for efficient solar energy harvesting
- Wide PV input voltage range (90~450VDC)
- Built-in anti-dust kit for enhanced durability in harsh environments
- Smart battery charge design to optimize battery life
- Intuitive touch button interface
- Dual AC Output function for flexible power distribution
2. Product Overview
This section provides a visual guide to the inverter's components and display.

Figure 1: Front view of the Daxtromn 10.2KW Hybrid Solar Inverter

Figure 2: Product Overview with labeled components and LCD display details
Component Identification:
- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Touch function buttons
- Power on / off switch
- AC input
- Main output
- Second output
- PV1 & PV2 input
- WIFI communication/RS-232 port
- Battery communication/RS-485 port
- Battery input

Figure 3: Various product views of the inverter
3. Setup and Installation
Proper installation is crucial for the safe and efficient operation of your solar hybrid inverter. All wiring must be performed by qualified personnel.
General Connection Diagram:

Figure 4: General connection diagram illustrating solar, generator/utility, battery, and home appliance connections.
Battery Connection:
CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between the battery and inverter. It may not be requested to have a disconnect device in some applications, however, it's still requested to have over-current protection installed.
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable as below.

Figure 5: Battery connection diagram and recommended cable sizes.
AC Input/Output Connection:
CAUTION!! Before connecting to AC input power source, please install a separate AC breaker between inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from over current of AC input. The recommended spec of AC breaker is 63A for 8.2KW/10.2KW.
CAUTION!! There are two terminal blocks with "IN" and "OUT" markings. Please do NOT mis-connect input and output connectors.
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.

Figure 6: AC Input/Output connection diagram and recommended cable requirements.
PV Connection and Module Selection:
CAUTION: Before connecting to AC input power source, please install a separate AC breaker between inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from over current of AC input. The recommended spec of AC breaker is 63A for 7.2KW/8.2KW/10.2KW.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for PV input connection. To reduce risk of injury, please use the proper recommended cable size as below.

Figure 7: Example installation diagram and PV module selection guidelines.
When selecting proper PV modules, please be sure to consider below parameters:
- Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
For operation without an external battery, the voltage from the solar panel must be above 120VDC for the inverter to function normally. If an external battery is connected, 90VDC is sufficient.
4. Operating Modes
The inverter offers various operating modes to suit different energy management needs.
Output Source Priority:

Figure 8: Output Source Priority settings.
The inverter allows configuration of load power source priority:
- Utility first (01 USB): Utility provides power as the first priority. Solar and battery energy provide power only when utility power is unavailable. If solar energy is insufficient, utility supplies power.
- Solar first (default) (01 SUB): Solar energy provides power to the loads as the first priority and charging second. Battery provides power only when solar energy and utility are not available, or if solar energy is insufficient.
- SBU priority (01 SBU): Solar energy provides power to the loads as the first priority. If solar energy is not sufficient to power all connected loads, battery energy will supply power to the loads at the same time. Utility provides power to the loads only when battery voltage drops to either low-level warning voltage or the setting point in program 12.
- MKS priority (01 nFS): Solar energy provides power to the loads as the first priority. If solar energy is not sufficient to power all connected loads, utility energy will supply power to the loads at the same time. The battery only supplies energy to the load as a backup power.
Various Working Modes:

Figure 9: Illustration of inverter working modes with and without battery connection.
Dual AC Output Function:
The inverter features a dual AC output function. When the main AC input (grid) is unavailable, and the battery voltage falls below a set threshold, the main AC output will automatically disconnect. In this scenario, the battery or PV power will only supply the second AC output.
WARNING: DO NOT CONNECT THE SECOND OUTPUT TO THE GRID, AS THIS WILL DAMAGE YOUR INVERTER.
5. Indicators and Controls
The inverter's LCD display, LED indicators, and function keys provide essential information and control.

Figure 10: LED indicator status and function key descriptions.
LED Indicators:
| LED Indicator | Color | Messages |
|---|---|---|
| INV/AC | Green | Solid On: Output is powered by utility in Line mode. Flashing: Output is powered by battery or PV in battery mode. |
| CHG | Green | Solid On: Battery is fully charged. Flashing: Battery is charging. |
| FAULT | Red | Solid On: Fault occurs in the inverter. Flashing: Warning condition occurs in the inverter. |
Function Keys:
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
6. Specifications
Detailed technical specifications for the Daxtromn 10.2KW Hybrid Solar Inverter (Model: AGH-10.2KW-PLUS).

Figure 11: Detailed technical specifications table.
| Feature | Specification |
|---|---|
| Model Number | AGH-10.2KW-PLUS |
| Rated Output Power | 10200W/10200VA |
| Maximum PV Input Power | 10200W (5400W * 2 channels) |
| Maximum Solar Charging Current | 160A |
| Nominal DC Voltage / Maximum DC Voltage | 360VDC / 500VDC |
| Start-up Voltage / Initial Feeding Voltage | 90VDC / 120VDC |
| Number of MPPT / Max Input Current | 2 / 18A |
| Nominal Output Voltage | 220/230/240VAC |
| Nominal Output Current | 44.3A |
| Max Conversion Efficiency (DC/AC) | 98% |
| Maximum AC Input Current | 50A |
| Nominal Operating Frequency | 50/60Hz (Auto detection) |
| Phase | 1-Phase |
| Dimensions (L*W*H) | 625*470*205mm |
| Net Weight | 16.5 kg |
| Output Type | DUAL |
| Certification | CE |
| Battery Voltage Range | 48VDC |
| Maximum Battery Current | 212.5A |
| Surge Power | 20400VA |
| Maximum AC Charging Current | 140A |
| Communication | RS232/RS485/WIFI/GPRS/Lithium Battery |
| Operating Temperature | -10~50°C |
| Storage Temperature | -15~60°C |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) |
7. Maintenance
Regular maintenance helps ensure the longevity and optimal performance of your inverter.
- Keep the inverter's ventilation openings clear of dust and debris to prevent overheating.
- Periodically inspect all wiring connections for tightness and signs of wear or corrosion.
- Ensure the inverter is installed in a clean, dry, and well-ventilated area, away from direct sunlight and corrosive substances.
- For cleaning, use a dry, soft cloth. Do not use liquid cleaners or solvents.
8. Troubleshooting
If you encounter issues with your inverter, consider the following general troubleshooting steps:
- Check all cable connections (PV, AC input, AC output, battery) to ensure they are secure and correctly wired.
- Observe the LED indicators and LCD display for any fault codes or warning messages (refer to Section 5 for details).
- Verify that the PV input voltage is within the specified range, especially if operating without a battery (above 120VDC).
- Ensure the battery voltage is within the nominal operating range (48VDC).
- If the inverter is not turning on, check the power switch and any external breakers.
- If the problem persists, contact customer support for assistance.
9. User Tips
Here are some helpful tips based on common questions and experiences:
- BMS Compatibility: For optimal battery management and safety, ensure both your inverter and battery have BMS (Battery Management System) functions to allow communication and automatic parameter adjustment. The inverter supports PACE and PYLON BMS protocols.
- PV Panel Configuration: The inverter's dual MPPTs allow you to connect two independent strings of solar panels. These strings can have different specifications, provided each string's voltage and current remain within the inverter's specified limits.
- Inverter Expansion: This inverter model does not support parallel or series connection of multiple inverters to increase total output power.
- Initial PV Voltage: Remember that if the inverter is operating without an external battery, the solar panel voltage must be at least 120VDC to initiate operation. With an external battery, 90VDC is sufficient.
10. Warranty and Support
The Daxtromn 10.2KW 2XMPPT On/Off Grid Solar Hybrid Inverter comes with a 1-year warranty.
For technical support, warranty claims, or any inquiries, please contact your seller or the manufacturer directly. When contacting support, please have your model number (AGH-10.2KW-PLUS) and purchase details readily available.