Hti HT-18 plus

Contents

Hti HT-18 plus Thermal Imager User Manual

Model: HT-18 plus

1. Introduction

The Hti HT-18 plus Thermal Imager is an advanced infrared temperature measurement device designed for a wide range of applications including electrical repair, PCB inspection, pipeline detection, building diagnostics, and general maintenance. Featuring a 256x192 infrared resolution and a 3.2-inch full-color screen, it provides detailed thermal images to quickly locate and diagnose problems. This manual provides essential information for the safe and effective operation of your thermal imager.

Hti HT-18 plus Thermal Imager front view
Front view of the Hti HT-18 plus Thermal Imager.

2. Package Contents

Please check the package contents upon receipt to ensure all items are present and undamaged:

  • 1 x Hti HT-18 plus Thermal Imager
  • 1 x USB Cable
  • 1 x User Manual
  • 1 x Carry Pouch
  • 1 x Carry Pouch Strap
  • 1 x Cardboard Package Box
Package contents of the Hti HT-18 plus Thermal Imager
All items included in the product package.

3. Device Overview

The HT-18 plus features an ergonomic design for comfortable handheld use. Key components include the infrared lens, visible light camera, 3.2-inch display, and intuitive control buttons.

Side view of the HT-18 plus Thermal Imager with lens cap
Side view showing the thermal lens with protective cap.
Back view of the HT-18 plus Thermal Imager with control buttons
Back view highlighting the control panel: Power, Menu, Select, Enter, and Navigation buttons.

Control Buttons:

  • Power Button: Turns the device on/off.
  • MENU Button: Accesses the main menu for settings and options.
  • SELECT Button: Confirms selections within menus.
  • ENTER Button: Confirms selections or actions.
  • Arrow Buttons (Up/Down/Left/Right): Navigates through menu options and adjusts settings.

4. Setup

4.1 Charging the Device

The HT-18 plus is equipped with built-in rechargeable 18650 batteries. To charge, connect the device to a power source using the provided USB cable. The battery indicator on the screen will show charging status.

4.2 Powering On/Off

  • To Power On: Press and hold the Power button until the screen illuminates.
  • To Power Off: Press and hold the Power button until the device shuts down.

4.3 Initial Settings

Upon first use, or after a reset, you may need to configure basic settings:

  1. Press the MENU button to access the main menu.
  2. Use the Arrow buttons to navigate to 'Settings'.
  3. Press ENTER to select 'Settings'.
  4. From here, you can adjust:
    • Language: Select your preferred language.
    • Unit: Choose between Celsius (°C) or Fahrenheit (°F) for temperature display.
    • Time Format: Set 12-hour or 24-hour format.
    • Set Time: Adjust the current date and time.
    • Auto Shutdown: Configure automatic power-off duration (5 minutes, 20 minutes, or off).

Video demonstrating menu navigation and temperature range selection on the HT-18 plus.

5. Operating Instructions

5.1 Basic Thermal Imaging

Once powered on, the device will display a real-time thermal image. Point the imager at the target object. The screen will show temperature readings, including maximum, minimum, and center point temperatures, along with an emissivity value (e).

Three Point Simultaneous Measurement Automatic Tracking feature
The imager automatically tracks and displays the hottest, coldest, and center points.

5.2 Adjusting Temperature Range

The HT-18 plus supports two temperature measurement ranges:

  • Low Range: -20°C to 120°C (-4°F to 248°F)
  • High Range: 120°C to 550°C (248°F to 1022°F)

To change the temperature range:

  1. Press the MENU button.
  2. Navigate to 'Settings' and press ENTER.
  3. Scroll to 'Temperature range' and press ENTER.
  4. Select 'Low' or 'High' using the Arrow buttons and confirm with SELECT or ENTER.
Temperature Measurement Range -20°C to +550°C and various application examples
The wide temperature range allows for diverse applications such as building, automotive, and electrical inspections.

5.3 Color Palettes

The device offers five color palettes to visualize thermal data:

  • Rainbow
  • Iron Red
  • Cold Color
  • White Heat
  • Black Heat

To change the color palette:

  1. Press the MENU button.
  2. Navigate to 'Color palette' and press ENTER.
  3. Select your desired palette using the Arrow buttons and confirm.
Five Color Palettes for thermal imaging
Different color palettes provide varied visual representations of temperature differences.

5.4 Emissivity Adjustment

Emissivity (e) is a measure of an object's ability to emit infrared energy. The HT-18 plus allows adjustment from 0.1 to 1.0. Correct emissivity setting is crucial for accurate temperature readings. Consult a table of common material emissivities for best results.

To adjust emissivity:

  1. Press the MENU button.
  2. Navigate to 'Emissivity' and press ENTER.
  3. Use the Arrow buttons to adjust the value and confirm.

5.5 Image and Video Capture

The device supports both still image photography and video recording. These can be stored on the built-in 4GB SD card.

  • To Capture an Image: While in live view, press the SELECT button (or designated capture button if available) to take a photo.
  • To Record Video: Navigate through the menu to 'Videos' or a dedicated video recording option and press ENTER to start/stop recording.
HT-18 plus Thermal Imager highlighting key features
Key features include high sensitivity, on-board recording, in-camera photography, autofocus, offline analysis, five color palettes, hotspot tracking, and dual light fusion.

6. Data Management

The HT-18 plus stores images in JPG format and videos on its internal 4GB storage. You can transfer these files to a computer for further analysis or viewing.

6.1 Transferring Files to Computer

  1. Connect the HT-18 plus to your computer using the provided USB cable.
  2. The device should appear as a removable storage device on your computer.
  3. Locate the image and video files and copy them to your computer.
  4. Some models may include analysis software. If so, install the software from the provided package or download it from the manufacturer's website to enhance your analysis capabilities.
Analysis software and video recording function, showing the device connected to a laptop via USB
Connect the HT-18 plus to a computer via USB to export video files and use analysis software.

7. Maintenance

7.1 Cleaning

  • Use a soft, dry cloth to clean the device's exterior.
  • For the lens, use a specialized lens cleaning cloth and solution to avoid scratches.
  • Do not use abrasive cleaners or solvents.

7.2 Storage

  • Store the device in its carry pouch in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Ensure the lens cap is on to protect the infrared lens.

7.3 Battery Care

  • Charge the battery regularly, even if the device is not in frequent use, to maintain battery health.
  • Avoid fully discharging the battery for extended periods.

8. Troubleshooting

If you encounter issues with your HT-18 plus, refer to the following common problems and solutions:

  • Device does not power on: Ensure the battery is charged. Connect to a power source and try again.
  • Inaccurate temperature readings: Check and adjust the emissivity setting for the material being measured. Ensure the correct temperature range (Low/High) is selected.
  • Screen is dim or unclear: Adjust the screen intensity in the 'Settings' menu. Clean the screen and lens if smudges are present.
  • Cannot transfer files to computer: Ensure the USB cable is securely connected. Try a different USB port or cable. Verify the device is recognized as a storage device.
  • Device freezes or becomes unresponsive: Perform a soft reset by holding down the Power button until the device restarts. If the issue persists, contact customer support.

9. Specifications

FeatureSpecification
Display Screen3.2'' Full-Color Screen
Infrared Image Resolution256×192
Visible Image Resolution0.3 Million Pixel
Thermal Sensitivity0.07°C
Temperature Measurement Range-20°C to 550°C (-4°F to 1022°F)
Measurement Precision±2.5°C or ±2.5%
Wavelength Coverage8-14um
Field Angle / Shortest Focus Length27°×35° / 0.5m
EmissivityAdjustable from 0.1 to 1.0
Focus ModeFixed
Image Capture Frequency8Hz
View OptionFull infrared and full vision Visible image with 25% step length
Storage MediumBuilt-in 4GB
Image FormatJPG
Power SupplyBuilt-in Rechargeable 18650 Batteries
USB InterfaceMicro USB2.0
Automatic Power-off Time5 minutes / 20 minutes / Off
Dimensions90 × 105 × 223 mm
Weight289g
Work Temperature0°C to 50°C
Storage Temperature-40°C to 80°C
Humidity<85% RH
Brand Namexguanmeter
Is Smart DeviceNo
StyleHandheld
OriginMainland China
CertificationCE

10. User Tips

  • For detecting subtle temperature differences, experiment with different color palettes to find the one that best highlights the anomalies.
  • When inspecting surfaces with varying emissivities (e.g., painted metal vs. bare metal), adjust the emissivity setting accordingly for more accurate readings.
  • The device can be useful for identifying potential water leaks behind walls by detecting temperature variations caused by moisture, though its primary function is not leak detection.
  • Utilize the analysis software on your computer to get more in-depth insights from your captured thermal images and videos.
Various application scenarios for the thermal imager
The HT-18 plus is suitable for diverse applications including motor, distribution box, car, PCB, floor heating, and circuit fault detection.

11. Warranty and Support

This product comes with a standard manufacturer's warranty. For detailed warranty terms, please refer to the warranty card included in your package or contact the seller directly. If you experience any issues or require technical assistance, please reach out to the product's customer support channel.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.