SNDWAY SW-DR60, SW-DR100

Contents

SNDWAY Dual Laser Distance Meter User Manual

Models: SW-DR60, SW-DR100

Thank you for purchasing the SNDWAY Dual Laser Distance Meter. This manual provides essential information for safe and effective use of your device.

1. Safety Regulations

Before using the instrument for the first time, please read the safety regulations and operation guide carefully. Improper operations without complying with this manual may cause damage to the device, influence measurement results, or cause personal injury to the user or a third party.

  • The instrument is not allowed to be disassembled or repaired in any way. It is forbidden to make any illegal modification or performance change to the laser emitter.
  • Keep the device out of reach of children and avoid use by any irrelevant person.
  • It is strictly prohibited to aim the laser at eyes or other parts of the body. Do not aim the laser at highly reflective surfaces.
  • Due to potential electromagnetic radiation interference, do not use the meter near aircraft or medical equipment. Avoid use in flammable or explosive environments.
  • Discarded meter devices should not be treated as household garbage. Please dispose of them according to national or local regulations.

2. Product Overview

The SNDWAY Dual Laser Distance Meter is a compact and robust device designed for precise measurements. It features a large LCD display, multiple measurement modes, and a magnetic back for convenient use.

Product demonstration video showcasing various features and measurement capabilities.

2.1. Display and Keys

The device features an intuitive display and easy-to-use buttons.

Diagram of the laser distance meter's display and buttons with labels

Detailed view of the meter's display and key functions.

  • Display: Screen lock indication, level bubble, auxiliary display area, unit, measuring mode, angle indication, laser indication, measuring reference indication, battery level indication, main display area.
  • Keys: Power-on/Measure, Add/Subtract/Lock screen, Power-off/Clear, Unit/Measuring reference, Function/Record.

3. Setup

3.1. Unpacking

Upon receiving your instrument, please check the contents against the packing list:

ItemNameQuantityNote
1Laser distance meter1
2Pouch1
3Strap1
4User manual1
5Color box1
6Type-C cable1
7Reflector1Just available for 100m models
Image showing the contents of the product package including the meter, pouch, strap, manual, charging cable, and box.

Contents of the product package.

3.2. Charging the Battery

The device is equipped with a 3.7V 850mAh Li-ion rechargeable battery. Use a compliant DC5V ≥1A Type-C charger (phone chargers are recommended).

  • If the instrument shows a low battery indicator, charge it immediately to avoid affecting measurement accuracy.
  • During charging, the battery icon will flash. When fully charged, the icon will be solid and stop rolling.
  • Charging time is approximately 1.5 hours.
Image showing the laser distance meter being charged via a Type-C cable.

The device features a Type-C charging port.

3.3. Power On/Off

  • Power On: In the off state, long press the MEAS button for 3 seconds to start the instrument. It will enter the test mode.
  • Power Off: In the on state, long press the OFF/CLEAR button for 3 seconds to turn off the instrument. If no operation is performed within 180 seconds, the instrument will shut down automatically.

3.4. Unit Setting

In length measuring mode, long press the UNIT button to enter the measuring units adjustment state. The instrument provides 6 optional units:

OptionLengthAreaVolume
10.000 m0.000 m²0.000 m³
20.00 m0.00 m²0.00 m³
30.0 in0.00 ft²0.00 ft³
40 1/16 in0.00 ft²0.00 ft³
50'00" 1/160.00 ft²0.00 ft³
60.00 ft0.00 ft²0.00 ft³

3.5. Measurement Reference Setting

Short press the UNIT button to set the measurement reference. The system default benchmark is bidirectional measurement.

Diagram showing bidirectional measurement reference for no-bend measurements.

Bidirectional measurement allows for no-bend measurements.

4. Operating Instructions

4.1. Measurement Modes

The instrument provides 9 optional measurement modes. Short press the FUN/RECORD button to enter mode selection. Use the UNIT button to switch modes and the MEAS button to select. Press OFF/CLEAR to return.

Icons representing various measurement modes: bidirectional, magnetic adsorption, rechargeable, single, continuous, area, volume, wall area, Pythagorean.

Icons for various measurement functions.

ModeDescription
Length ModeMeasures single or continuous distances.
Area ModeCalculates the area of a rectangle.
Volume ModeCalculates the volume of a cube.
Wall Area ModeCalculates the total area of multiple walls.
Pythagorean MeasurementCalculates height or hypotenuse using Pythagorean theorem.
Angle MeasurementMeasures angles using the built-in tilt sensor.
Addition/SubtractionAdds or subtracts measurements.

4.1.1. Single Measurement (Length Mode)

Press MEAS to emit the laser and lock the measuring point. Press MEAS again for a single distance measurement. The result will be displayed in the main display area. In bidirectional measurement, the auxiliary display area shows distances from both ends.

4.1.2. Continuous Measurement (Length Mode)

Long press MEAS to enter continuous measurement mode. The screen displays real-time measurement data, maximum, and minimum values. Short press MEAS or OFF/CLEAR to exit.

4.1.3. Midpoint Finding

Set the reference to bidirectional. Long press MEAS to start continuous measurement. Follow screen prompts (arrows) to find the midpoint.

Diagram showing the center point positioning feature with bidirectional laser measurement.

Center Point Positioning using bidirectional reference.

4.1.4. Area Measurement

Press MEAS to measure the first side (length), then press MEAS again for the second side (width). The auxiliary display shows length and width. The main display shows the calculated area. Press OFF/CLEAR to clear and remeasure.

4.1.5. Volume Measurement

Press MEAS for the first side (length), then for the second side (width), and finally for the third side (height). The instrument automatically calculates and displays the volume. The auxiliary display shows length, width, and height. Press OFF/CLEAR to clear and remeasure.

4.1.6. Wall Area Measurement

Press MEAS to measure the height of the wall. Then, measure the width of each wall segment (e.g., width 1, width 2, etc.) by pressing MEAS for each. The instrument calculates the area of each wall segment (height × width) and the total wall area (height × (width 1 + width 2 + ... + width n)).

Diagrams illustrating area and volume measurement modes.

Examples of Area and Volume measurement.

4.1.7. Pythagorean Measurement

This mode calculates unknown lengths using the Pythagorean theorem. Ensure the hypotenuse is longer than the right side for accurate results. Always measure from the same starting point and in the order of hypotenuse and legs.

  • Calculate Height by Measuring Angle: Press MEAS to measure the hypotenuse (a). The instrument simultaneously measures the angle and calculates horizontal distance (b) and vertical height (h).
  • Measure Height of Right Triangle: Press MEAS for hypotenuse (a), then for the right angle leg (b). The instrument calculates height (h).
  • Measure Hypotenuse of Right Triangle: Press MEAS for side (a), then for leg (b). The instrument calculates hypotenuse (x).
  • Measure Sum of Triangle Base: Press MEAS for hypotenuse (a), then for another hypotenuse (b), and finally for leg (c). The instrument calculates height (x).
  • Measure Triangle Auxiliary Height: Press MEAS for hypotenuse (a), then for side (b), and finally for the other hypotenuse (c). The instrument calculates auxiliary height (x).
Diagram illustrating Pythagorean measurement for calculating height.

Pythagorean measurement example.

4.1.8. Addition and Subtraction Measurement

This function allows you to add or subtract consecutive measurements.

  • Length Addition/Subtraction: Short press +/-. A "+" will appear, indicating addition mode. Continue measuring, and values will be added. Press +/- again for subtraction mode ("-" appears), and subsequent measurements will be subtracted.
  • Area/Volume Addition/Subtraction: The process is similar to length. Measure the first area/volume, then short press +/- for addition mode. Measure the second area/volume, and the instrument will calculate the sum. For subtraction, press +/- again to switch modes.

4.2. Electronic Level Bubble

The instrument includes an electronic level bubble for measuring the levelness of a plane, providing more accurate and efficient results.

Image showing the electronic level bubble feature on the device display.

Electronic level bubble for precise leveling.

4.3. Electronic Angle Sensor

The built-in tilt sensor provides real-time display of angle data, capable of measuring the angles of both the bottom and side edges.

Image showing the electronic angle sensor displaying a 45-degree angle.

Electronic angle sensor displaying real-time angle data.

4.4. Automatic Screen Rotation and Lock

The instrument supports automatic screen rotation. Long press the +/- button to lock the screen direction (a lock icon will appear). Long press +/- again to cancel the screen orientation lock.

Images demonstrating automatic screen rotation and lock feature based on device orientation.

Automatic screen rotation and lock feature.

4.5. Data Recording

The instrument automatically stores measurement results.

  • View Records: Long press the FUN/RECORD button.
  • Navigate Records: Short press the +/- button to scroll forward or backward through records.
  • Clear Records: Long press the OFF/CLEAR button to clear all records.

5. Maintenance

5.1. Storage

  • Do not store the instrument in high temperature or humid environments for extended periods.
  • If not used for a long time, store the instrument in its cloth box in a dry and cool place.

5.2. Cleaning

  • Keep the surface of the instrument clean. Wipe dust with a damp soft cloth.
  • Do not use corrosive liquids to clean the instrument.
  • The laser window and focusing mirror should be wiped in the same manner as other optical devices.

5.3. Battery Maintenance

If the instrument is not used for a long time, it is recommended to fully charge it and recharge it once every six months to prevent battery discharge damage.

6. Troubleshooting

During use, the main display area may show the following error messages:

InfoCauseSolution
ErrOut of measuring rangeUse the instrument within the measurement range.
Err1Weak signalMeasure a target point with strong reflectivity.
Err2Strong signalMeasure a target point with weak reflectivity.
Err3Low battery voltageCharge the battery.
Err4Out of operating temperature rangeUse the instrument in the specified environment.
Err5Wrong Pythagorean measurementRemeasure, ensure the hypotenuse is longer than the right side.
Err6Angle sensor failureReturn to factory for repair.

7. Specifications

ItemSW-DR60SW-DR100
Measuring range60m (Unidirectional)
120m (Bidirectional)
100m (Unidirectional)
200m (Bidirectional)
Accuracy±(2mm + d*1/10000)* (Unidirectional)
Dip measuring range±90°
Continuous measurement✓
Area/Volume measurement✓
Wall area measurement✓
Pythagorean measurement✓
Angle and height measurement✓
Length addition/subtraction measurement✓
Max/Min value✓
Electronic level bubble✓
Automatic screen rotation✓
Magnetism✓
Laser levelII
Laser type630-670nm, <1mW
Max storage100 units
Auto laser-off20s
Auto power-off180s
Backlight time60s
Battery3.7V 850mAh Li-ion
Charge timeAbout 1.5 hours
Charging specificationDC5V 0.75A Type-C
Operation times at full charge8000 times (Unidirectional)5000 times (Bidirectional)
Storage temperature-20°C ~ 60°C
Working temperature0°C ~ 40°C
Storage humidity20% ~ 80% RH
Dimension115 x 50 x 24.5mm

Note: "d" indicates the actual distance. In harsh environments (e.g., strong sunlight, extreme temperature fluctuations, weak reflective surfaces, low battery), measurement results may have larger errors. Using a reflective plate can improve accuracy in such conditions.

8. User Tips

  • For maximum precision when measuring from an edge, consider using the single laser measurement function. While dual laser measurement is convenient, some users report slightly higher error margins (around 3mm) compared to single laser mode (1-2mm error from the edge).
  • Remember to check and change the measurement units (meters, feet, inches) as needed using the 'UNIT' button to suit your project requirements.

9. Warranty and Support

If you encounter any quality issues or have questions regarding the use of the instrument, please contact your local distributor or the SNDWAY instrument manufacturer. We are committed to providing timely solutions.

Sndway Technology (Guangdong) Co., LTD
Address: Sndway Science & Technology Industrial Park, 58 Tuanjie Road, Humen 523930, Dongguan, China
Service Hotline: 400-125-6969
Tel: 0769-85265688
Web: www.sndway.com
E-mail: market@sndway.com

Product Standard: GB/T 14267-2009

Certifications: CE, FCC, RoHS