1. Introduction
This manual provides essential information for the installation, operation, and maintenance of the Agras XAG P100Pro Original Peristaltic Pump Tube Kit. This kit is designed as a replacement part for agricultural drones, specifically the XAG P100Pro model. It is crucial to read and understand all instructions before attempting any installation or repair.
Product Overview
The Peristaltic Pump Tube Kit is a critical component for the liquid delivery system in agricultural drones. It is made from durable rubber material and is available in quantities of 1 or 2 pieces per kit.
Video: Unboxing and handling of the XAG P100Pro Peristaltic Pump Tube Kit.
2. Safety and Warnings
- Read All Instructions: Always read all instructions thoroughly before using this product to ensure safety and prevent damage.
- Professional Installation Recommended: This product is an agricultural drone accessory repair part. Replacing it requires a certain level of hands-on ability and technical expertise. If you lack sufficient technical skills, it is strongly advised not to attempt installation yourself. This manual does not include detailed installation guidance.
- Chemical Exposure Warning: WARNING: This product can expose you to chemicals including phthalates (DEHP), which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, please visit www.P65Warnings.ca.gov.
3. Installation Instructions
The installation of the peristaltic pump tube kit involves replacing existing components within the agricultural drone's liquid delivery system. Due to the specialized nature of agricultural drones and the precision required, professional installation is highly recommended.
General Installation Steps:
- Ensure the agricultural drone is powered off and all liquid tanks are empty and depressurized.
- Carefully locate the faulty peristaltic pump tube within the drone's system.
- Gently remove the old, faulty tube, noting its orientation and connections.
- Install the new XAG P100Pro Peristaltic Pump Tube Kit, ensuring all connections are secure and the tube is correctly seated.
- Verify that the tube is not kinked or obstructed and that it can move freely within its housing.
- Perform a system check as per your drone's main operating manual to confirm proper function before use.

Image: XAG P100Pro Peristaltic Pump Tube Kit in its original packaging, showing part number 14-006-00007.

Image: Close-up of the peristaltic pump tube, displaying markings such as 'Innovasil SGU4907508814B - XAG' and 'MAX 10 PSI'.
4. Operating the Peristaltic Pump Tube Kit
The peristaltic pump tube itself does not have a separate operating procedure. Its function is integral to the agricultural drone's liquid spraying system. Once correctly installed, the tube operates as part of the drone's peristaltic pump, which is controlled by the drone's flight management system.
Refer to your Agras XAG P100Pro drone's main operating manual for instructions on how to activate and manage the spraying system, which will utilize this pump tube.
5. Maintenance
Proper maintenance of the peristaltic pump tube is essential for the longevity and efficiency of your agricultural drone's spraying system.
Maintenance Guidelines:
- Regular Inspection: Periodically inspect the pump tube for any signs of wear, cracks, leaks, or hardening. Replace immediately if any damage is observed.
- Cleaning: After each use, especially when spraying corrosive or viscous liquids, flush the pump system with clean water to prevent residue buildup and extend tube life.
- Storage: When not in use for extended periods, ensure the pump tube is clean and dry. Store the drone and its components in a cool, dry place away from direct sunlight and extreme temperatures.
- Replacement: Peristaltic pump tubes are wear-and-tear parts. Replace them according to the drone manufacturer's recommended schedule or at the first sign of reduced performance or damage.
6. Troubleshooting
If you experience issues with your drone's spraying system after installing the peristaltic pump tube, consider the following common troubleshooting steps:
Common Issues and Solutions:
- No Liquid Flow:
- Check if the pump tube is correctly installed and not kinked or blocked.
- Ensure the liquid tank has sufficient liquid and the intake filter is not clogged.
- Verify that the pump motor is functioning.
- Inconsistent Spray Pattern:
- Inspect the pump tube for any internal damage or blockages that might affect flow consistency.
- Check spray nozzles for clogs or wear.
- Leaks from the Pump System:
- Examine the pump tube for any punctures or tears.
- Ensure all connections and clamps are tight and secure.
- Verify that the tube is properly seated within the pump mechanism.
If issues persist after troubleshooting, consult a qualified drone technician or contact the manufacturer for further assistance.
7. Specifications
| Feature | Specification |
|---|---|
| Product Name | Agras XAG P100Pro Original Peristaltic Pump Tube Kit Part |
| Part Number | 14-006-00007 |
| Model Number | XAG P100Pro |
| Material | Rubber |
| Quantity Options | 1 pcs, 2 pcs |
| For Vehicle Type | Airplanes (Agricultural Drones) |
| Maximum Pressure | 10 PSI |
| Origin | Mainland China |
| Recommended Age | 14+ years |
| Package Length | 20 cm |
| Package Width | 10 cm |
| Package Height | 5 cm |
| Package Weight | 0.15 kg |
8. User Tips
- Consider Multi-Packs: If you frequently replace pump tubes or manage multiple drones, consider purchasing the 2-piece kit option to ensure you always have a spare on hand.
9. Warranty and Support
For any inquiries regarding the Agras XAG P100Pro Peristaltic Pump Tube Kit, please contact the manufacturer or their authorized representative:
Manufacturer Information:
- Company Name: Ritozcase Wudoumi UAV Technology Store
- Address: No. 3, Lane 8, Wuhe Road, Bantian Street, Longgang District, Shenzhen City, 509
- Email: 286537265@qq.com
- Phone: 13048808832
EU Authorized Representative:
- Company Name: SUNBURST INNOVATIONS SP. Z O.O.
- Address: ul. FRANCISZKA KLIMCZAKA 5, lok 95, 02-797 Warszawa, Poland
- Email: invechfans@outlook.com
- Phone: (+48)732099593
Additional item guides and documents may be available. Please refer to the official product page or contact support for more information. A user manual in PDF format is also available for reference.