MatSee Plus PJ-1103A

Contents

MatSee Plus Tuya Smart WiFi Energy Meter Instruction Manual

Model: PJ-1103A

Bidirectional 2-Way Energy Monitoring with Clamp 80A/120A

1. Introduction

Thank you for choosing the MatSee Plus Tuya Smart WiFi Energy Meter. This device is designed to monitor both solar produced and consumed power in real-time, offering comprehensive electricity statistics through the Tuya Smart or Smart Life application. It supports bidirectional measurement and is available in 1-channel or 2-channel configurations with 80A or 120A current clamps. This manual provides essential information for safe installation, operation, and maintenance of your energy meter.

2. Safety Information

  • Installation should only be performed by qualified personnel.
  • Ensure the main power supply is disconnected before any installation or wiring.
  • Do not operate the device if it is damaged or has been exposed to moisture.
  • Verify all connections are secure to prevent electrical hazards.
  • The device is designed for AC 100-240V 50/60Hz systems. Do not exceed the rated voltage or current.

3. Package Contents

  • Tuya Smart WiFi Energy Meter (Model PJ-1103A)
  • Current Transformer(s) (CT) (1 or 2, depending on chosen model: 80A or 120A)

Note: Please check that all components are present and undamaged upon unboxing.

Tuya Smart WiFi Energy Meter with two 80A current clamps and power alarm icon

Product overview with two 80A current clamps.

4. Specifications

FeatureSpecification
ModelPJ-1103A
Rated VoltageAC 100-240V 50/60Hz
Measurable Current Range (80A Option)0.2A - 80A
Measurable Current Range (120A Option)0.2A - 120A
Wireless FrequencyWiFi 2.4GHz (5GHz not supported)
Ambient Temperature Range-10°C ~ 55°C
Communication MethodWi-Fi
DirectionBidirectional 2 Way
Channel Option1 or 2 Channels
App NameTuya Smart, Smart Life
CertificationsCE, RoHS
Module Dimensions (L x W x H)50mm x 46mm x 18mm
80A CT Dimensions (L x W x H)26mm x 23mm x 40mm (10mm hole)
120A CT Dimensions (L x W x H)31mm x 32mm x 46mm (16mm hole)

5. Setup and Installation

5.1 Physical Installation

The energy meter is designed for 35mm DIN rail mounting. Ensure the module is securely attached within your electrical panel.

Diagram showing 35mm DIN rail mounting for the energy meter

35mm DIN Rail Mounting.

5.2 Wiring Instructions

IMPORTANT: Disconnect all power before proceeding with wiring. Incorrect wiring can cause damage to the device or electrical system.

The current transformers (CTs) are of an open/close design for easy and safe installation without disconnecting the main circuit wires.

Image showing an open/close current transformer (CT) for safe installation

Open and close CT for easy and safe installation.

General Wiring Principle:

Connect the Live (L) and Neutral (N) wires from your AC distribution box to the corresponding L and N terminals on the energy meter. The CTs (S1, S2) are connected to the module's S1 and S2 terminals for each channel (A and B).

Note: When installing, please ensure that the circuit measured by the CT is in the same phase as the circuit powered by the module.

Wiring for 1-Channel Meter:

If you have a 1-channel meter, connect only one CT to either Channel A or Channel B terminals (S1, S2). Leave the other channel's terminals unconnected.

Wiring diagram for 1-channel energy meter with one current transformer (CT)

Wiring Diagram for 1-Channel Meter.

Wiring for 2-Channel Meter:

For a 2-channel meter, connect one CT to Channel A terminals (S1, S2) and the second CT to Channel B terminals (S1, S2).

Wiring diagram for 2-channel energy meter with two current transformers (CTs)

Wiring Diagram for 2-Channel Meter.

Example: Measuring Energy Consumption/Generation:

The diagrams below illustrate how to connect the CTs for measuring energy consumption from the grid or energy generation from a solar panel system.

Diagram showing how to measure energy consumption from the grid with CTs

Measuring Energy Consumption from Grid.

Diagram showing how to measure energy generation from a solar panel with CTs

Measuring Energy Generation from Solar Panel.

Diagram showing how to measure both forward and reverse energy flow with CTs

Measuring Forward and Reverse Energy (from Grid, to Grid).

5.3 App Pairing

Follow these steps to pair your energy meter with the Tuya Smart or Smart Life app:

  1. Ensure your smartphone is connected to a 2.4GHz WiFi network.
  2. Open the Tuya Smart or Smart Life app.
  3. Press and hold the pairing button on the energy meter until the indicator light flashes rapidly (usually 5-10 seconds). This puts the device into pairing mode.
  4. In the app, tap the '+' icon to add a device. The app should automatically detect the "WiFi dual meter".
  5. Follow the on-screen prompts to complete the pairing process.

Video demonstrating the app pairing process and basic energy monitoring.

6. Operating Instructions

Once paired, you can monitor and manage your energy meter through the Tuya Smart or Smart Life app.

6.1 Real-time Monitoring

The app provides real-time data for each channel (A and B) and total values:

  • Total Forward Energy: Total energy consumed.
  • Total Reverse Energy: Total energy generated (e.g., from solar panels).
  • Voltage (V): Current voltage.
  • Total Power (W): Instantaneous total power.
  • Frequency (Hz): Grid frequency.
  • Channel A/B Data: Active power (W), Current (mA), Power factor for each channel.
App interface showing real-time energy monitoring for two channels, including generating and consuming power

App interface displaying real-time generating and consuming energy.

App interface showing detailed forward and reverse energy readings for two channels

App interface displaying forward and reverse energy readings.

6.2 Electricity Statistics

View historical electricity data for each channel and total, broken down by day, month, and year, for both forward and reverse directions.

  • Hourly Electricity (KWh)
  • Daily Electricity (KWh)
  • Monthly Electricity (KWh)
  • Yearly Electricity (KWh)
App interface showing electricity statistics over day, month, and year

Electricity statistics view in the app.

6.3 Alarm Settings and Buzzer Warning

Configure various alarm thresholds and enable/disable the buzzer warning:

  • Report Rate Setting: Adjust how frequently data is reported (e.g., every 10 seconds).
  • Alarm Setting: Set thresholds for over power (A/B), over current (A/B), over voltage, and under voltage.
  • Buzzer: Toggle the audible buzzer warning for alarms.
  • Alarm History: Review past alarm events.
App interface showing alarm settings, including report rate and various thresholds

Alarm and Report Rate Settings.

App interface showing the toggle for the buzzer warning

Buzzer Warning toggle in app settings.

App interface showing a list of past alarm events

Alarm History in the app.

6.4 Automation (Scenes)

Create custom automation rules (scenes) within the Tuya Smart/Smart Life app to integrate your energy meter with other Tuya-compatible smart devices. For example, you can set a condition where if the power consumption on a channel reaches a certain value, it triggers a Tuya switch to turn on or off, or sends a notification.

App interface for creating automation scenes, showing various trigger conditions

Create Scene: Trigger conditions based on device status.

App interface for creating automation scenes, showing various actions like controlling a single device or sending notifications

Create Scene: Actions for automation.

7. User Tips

  • Data Export: While the app provides detailed historical data, direct export to formats like Excel is not a standard feature. You may need to manually record or screenshot data for external analysis.
  • Scene Automation: This WiFi energy meter does not require a separate Zigbee hub for creating scenes with other Tuya WiFi devices. All automation can be configured directly within the Tuya Smart/Smart Life app.
  • CT Orientation: Ensure the CTs are installed with the correct orientation as indicated by arrows or markings to ensure accurate forward and reverse energy readings.

8. Troubleshooting

  • Device not powering on: Check the L and N wiring connections and ensure the main power supply is active.
  • App pairing failure: Ensure your phone is on a 2.4GHz WiFi network, the device is in pairing mode (flashing indicator), and your WiFi signal is strong. Try resetting the device and re-initiating pairing.
  • No energy readings: Verify that the CTs are correctly installed around the live wire(s) and securely connected to the S1/S2 terminals. Check the CT orientation.
  • Incorrect readings: Double-check the CT installation and ensure the measured circuit is in the same phase as the module's power supply.
  • Buzzer not working: Check the 'Buzzer' setting in the app to ensure it is enabled. Verify alarm thresholds are set appropriately.

9. Maintenance

  • Keep the device clean and free from dust. Use a dry, soft cloth for cleaning.
  • Avoid exposing the device to extreme temperatures, direct sunlight, or high humidity.
  • Do not attempt to disassemble or repair the device yourself. Contact customer support for assistance.

10. Warranty and Support

This product comes with a standard manufacturer's warranty. For warranty claims, technical support, or any questions regarding the product, please contact the MatSee Plus Official Store customer service. Please have your purchase details and product model number ready when contacting support.

Certification document for the energy meter, showing CE and RoHS compliance

Product Certifications.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.