Introduction
Thank you for choosing the AIKE AK2005H High Speed Hand Dryer. AIKE specializes in the R&D of high-speed hand dryers.
Please read this manual thoroughly before using the unit to ensure safe and correct installation or operation. Keep this manual in a safe place for future reference.
We hope you enjoy the experience that the AK2005H brings to you.
Safety Cautions
Warning: Improper use may result in personal injury or accidents.
Prohibited Actions:
- Do not open the front panel. Otherwise, it may cause electric shock risk.
- Do not let children hang on the unit. Otherwise, the unit may be at risk of falling.
- Do not use in places where water is directly splashed or in places prone to freezing. Otherwise, it may cause electric shock and unit malfunction.
- Do not splash water. Otherwise, it may cause electric shock risk.
- Do not reform and perform unnecessary disassembling. Otherwise, it may cause fire, electric shock, and injury accidents.
Important Safety Instructions:
- Power must be turned off during maintenance. Otherwise, it may cause electric shock risk.
- Please use AC power. If the rated voltage exceeds 10%, the unit will malfunction. It may cause fire, electric shock, and unit malfunction if an incorrect power source is used.
- Use fixed lines. If used in combination with other appliances, it may cause abnormal heat in the shunt outlet and cause fire.
- Drain tank and air filter must be installed before using unit. It may cause leakage or electric shock accidents if water enters the unit.
- If the unit is not working or has abnormal conditions, please cut off the power to prevent accidents; also turn off the leakage circuit breaker, and then contact the supplier to check or maintenance. Otherwise, it may result in fire accidents due to electric shock, leakage, and short circuit.
Features
- High speed air flow, fast dry your hands within 7-10 seconds.
- Intelligent temperature control: automatically turns on or off the heating system based on ambient temperature, providing comfort in both winter and summer.
- Five safety protections: overtime protection, over-current protection, overheat protection, short circuit protection, motor anti-blocking.
- Removable drain tank: keeps the ground clean.
- Dual wave-shape outlets: enable faster drying and lower noise.
- Equipped with a Two-Stage HEPA Filter that captures 99.97% of dust and allergens.

Figure: Two-Stage HEPA Filter System

Figure: Key Features Overview
Specifications
| Attribute | Value | Attribute | Value |
|---|---|---|---|
| Brand Name | AIKE | Model Number | AK2005H |
| Voltage | AC100-130V / AC220-240V | Rated Power | 1750-2050W |
| Motor | Brush motor | Motor Power | 750W |
| Case Material | ABS Plastic | Drying Time | 7~10s |
| Air Speed | 90m/s | Air Temperature | 20-40℃ |
| Dimensions | 300x220x685mm | Net Weight | about 8.5kg |
| Protection Class | Class II | Waterproof | IP24 |
| Certification | CB, CE, RoHS | Sensor | Yes |
| Application | Hotel, Commercial, Household | High-concerned chemical | None |

Figure: Product Dimensions
Parts Name

Figure: Key Components
Main Components:
- Drying time and fault display: LED screen on top.
- Power indicator: Light indicating power status.
- Self check indicator: Light indicating system status.
- Receiver: Sensor for hand detection.
- Hand drying area: The space where hands are inserted for drying.
- Unit: The main body of the hand dryer.
- Air filter: Filters incoming air.
- Drain tank: Collects excess water.
- Drain hose: Connects to the drain tank.
- Heating switch: Controls the heating element.
- Speed switch: Adjusts air speed.
- Power switch: Main power control.
- Terminal Blocks: For electrical wiring connections.
- Mounting plate: Used for wall installation.
Installation
Precautions before Installation
- Do not install the product with power on.
- The unit must be installed by a professional in a suitable place.
- Wear gloves when installing to prevent injury.
- Ensure the power supply matches the device specifications.
- Install a leakage breaker during the installation process.
Avoid these locations:
- Temperatures outside -10°C to 40°C.
- Direct water contact or prone to freezing.
- Direct or strong sunlight.
- Easy condensation.
- Presence of corrosive, neutral, or reductive gases.
- Sea level lower than 0m or higher than 2000m.
Recommended Installation Location:
- Install at the position shown in the diagram below. The bottom of the unit must be at least 150mm higher than the floor or any objects under it.
- The left side of the unit must be at least 150mm away from any walls due to the power switch location.
- Ensure there are no mirrors or walls near the right side (recommended distance at least 100mm) to prevent water splatter.
- Avoid locations where people or doors might bump into the unit.
- Choose a completely flat surface on the wall.

Figure: Installation Steps Overview
Installation Procedures
- Power Supply: Use a single-phase alternating rated voltage supply (do not use with a power supply exceeding rated voltage ±10%). If the power cord needs replacement, use a cord between 1.5mm² and 2mm² thick. A 2.5mm² cord is recommended for lengths over 11m.
- Wire the Unit:
- Embed the switchbox in the installation location. Uncover the switchbox and wire the power cord.
- If an uncovered switchbox is not used, the power cord will be pushed out of the unit.

Figure: Hardwired Connection Diagram
- Fixed Installation Board: Fix the mounting plate to the wall using the provided accessories (six installation screws). For concrete walls, use expansion tubes and screws. For non-concrete walls, reinforce the wall before installation.
- Remove the Unit's Front Panel: Remove the drain tank, then remove the two screws of the front panel to detach it.
- Fix the Unit: Pull the power cord through the hole on the back. Hang the unit on the hook of the installation panel. Pull the unit into the wall and tighten the safety screws to secure it.
- Connect Power Cord: Loosen screws on the terminal box, connect the power cord, and tighten securely. Bind the power cord using the clip to the right of the terminal box.
- Install Terminal Box Cover: Make sure wires are not pinched. If wires are in front of the terminal box cover, move them to the right.
- Install Front Panel: Insert the 3 front panel chuckholes into the unit and replace the 2 screws.
- Attach Drain Tank: Securely attach the drain tank.
- Insert Air Filter: Ensure the air filter is all the way in.
Operation
- Hand Drying: Put your hands into the dry hand area. The machine will automatically activate high-speed wind. Slowly move your hands up and down until they are dry. When you remove your hands from the outlet for about 0.5 seconds, it automatically cuts off power and stops working.
- Heating Function: The unit is equipped with a heating switch. When hot air is needed, turn on the heating switch.
- Automatic Shut-off: If the hand dryer continuously works for more than 25 seconds, the power will automatically turn off to prevent continuous operation due to an item attached to the sensor. The machine will restart normally when hands are re-inserted.
Video: AIKE Hand Dryer in operation, demonstrating fast drying and safety features.

Figure: Fast Drying Action

Figure: Intelligent LED Display

Figure: Safety Protection Features
Maintenance
Draining and Cleaning the Drain Tank (Weekly)
The drain tank collects water blown off hands. Empty it regularly to prevent accumulation and odors.
- Pull the drain tank out horizontally.
- Pull the cover up in the direction of the arrow.
- Remove the entire cover.
- Wash out the interior of the drain tank.
- Close the water tank cover.
- Confirm the two locations are firmly inserted.
- Re-attach the drain tank to the unit.
- Add 200cc (around 1 cup) of water through the drain hole to prevent clogging.
Cleaning the Unit Body
Clean the unit body before it gets obviously dirty. The antibacterial coating is effective when bacteria are exposed to the coated surfaces, but less effective when surfaces are very dirty.
- Clean with a soft cloth dampened with neutral agent, then dry with a soft cloth.
- To remove dirt from the sensor, turn off the power switch.
Caution:
- Wear gloves when cleaning.
- Only use neutral cleaning agents.
- Do not use thinner, acidic or alkaline toilet cleaners, or nylon brush, as they may damage the surface.
- Only use alcohol (83% concentration or below) to clean the hand drying area.
- Do not use the unit outside the hand-drying area.
- If using chemical cloths, read their instructions first.
Cleaning the Air Filter (Weekly)
- Pull the air filter out by the handle.
- Beat it lightly by hand or use a vacuum cleaner.
- If very dirty, wash it off with cold or warm water.
- If washed, dry it as much as possible.
- Re-attach to the unit, inserting it all the way in until it stops. (If the air filter is not in place, dirt will enter the unit, shortening its service life and affecting antibacterial results.)
Prohibited actions for air filter:
- Do not expose to fire.
- Do not use a hair dryer to dry.
Troubleshooting
If you discover the following circumstances, inspect and handle as follows:
| Problem | Check | Action |
|---|---|---|
| No air flows if hands are inserted | Does the display indicator light up? Is the power switch on? Are you putting your hands all the way in? | Turn the ground fault circuit breaker on. Turn the power switch on. Put hands all the way in. |
| Machine works long time after hands drawn out | Any dirt or foreign body on sensor? | Switch off the power button, then remove dirt or foreign body on sensor after the power light goes out. When finished, switch on power button. |
| No hot wind | The unit has a heater inside, any dirt on heating sensor? | Is the ambient temperature too high? |
If the above actions do not work, turn off the power and the ground fault circuit breaker, and call your dealer to inspect and repair if necessary.
Electrical Schematic

Figure: Electrical Schematic
| Status | Introductions | Status | Introductions | Solution |
|---|---|---|---|---|
| Power indicator light | Extinguish | Power not supply | Check the external power source, close the power switch | |
| Self-check indicator light | Extinguish | Do not work | Master board fuse blew out | Check motor connecting wires and the rotor foreign material, restart to work |
| Timing digital tube | Always light | Working | Motor fault | Clear workspace foreign material, restart to work |
| Timing digital tube | Flashing light | Digital changes | Countdown work | Trick or working time longer than 25s |
| Timing digital tube | Frequency display 88 | Indicate drying time finished |
User Tips
- For optimal drying, ensure your hands are fully inserted into the drying area and move them slowly.
- Regularly check and empty the drain tank to maintain hygiene and prevent odors.
- Clean the air filter weekly to ensure efficient operation and prolong the unit's lifespan.
- If the unit is installed in a high-traffic area, consider more frequent cleaning of the drain tank and air filter.
Packing List
| Item | Quantity | Description |
|---|---|---|
| Unit | 1 | AIKE Jet Hand Dryer AK2005H |
| Air filter | 1 | Replacement air filter |
| 5*25 Self-tapping screw | 6 | For mounting |
| Allen wrench | 1 | Tool for installation |
| Product certificate (include warranty card) | 1 | Warranty and product information |
| 5mm Expansion pipe | 6 | For mounting |
| Mounting plate | 1 | For wall installation |
| User manual | 1 | This document |
Warranty & Support
AIKE offers a 2-year worry-free replacement guarantee. For non-human damage, AIKE will send new parts and provide service for free.
For further assistance or inquiries, please contact AIKE Appliances Store:
- Store Name: AIKE Appliances Store
- Store URL: https://m.aliexpress.com/store/storeHome.htm?sellerAdminSeq=2667913003
- Store Opened: July 22, 2022
- User Manual (PDF): A detailed user manual in PDF format is available for download. View User Manual (PDF)
Contact Information:
Zhejiang AIKE Appliances Co., Ltd.
Add: Yong'an Industry Zone, Taizhou, Zhejiang
E-mail: support@zjaike.com
Tel: 0086-0571-86089873
Website: www.aike.com