KKMOON KG316T-II

Contents

AC 220V 25A Digital Programmable Timer Din Rail Electronic Timer Time Switch Controller

Model: KG316T-II | Brand: KKMOON

1. Introduction

This digital programmable timer is a reliable, durable, and accurate electronic time switch designed for controlling various electrical equipment. It features a clear LCD display and offers up to 16 ON/OFF settings per day or week, with 15 combinations of daily programs. Its primary function is to automatically turn electrical equipment on and off, contributing to energy saving and convenient operation. It is widely applicable in settings such as street lighting, light boxes, radios, televisions, and other household or industrial electrical systems.

Front view of the KG316T-II Digital Programmable Timer highlighting key features.
Front view of the KG316T-II Digital Programmable Timer, showcasing its LCD display and control buttons. Key features highlighted include energy saving, stable performance, LCD display, 16 ON/OFF settings, and a premium ABS shell.

2. Safety Information

Please read and understand all safety instructions before installing or operating this device. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Electrical Hazard: Installation and wiring should only be performed by a qualified electrician in accordance with local electrical codes and regulations.
  • Power Disconnection: Always disconnect power at the circuit breaker or fuse box before installing, wiring, or servicing the timer.
  • Voltage Compatibility: Ensure the supply voltage (AC 220V) matches the timer's specifications.
  • Load Capacity: Do not exceed the maximum contact capacity of 25A 220V AC (Resistive Load). Overloading can cause damage to the timer and connected equipment, and poses a fire risk.
  • Environmental Conditions: Do not expose the timer to extreme temperatures, direct sunlight, moisture, or corrosive environments.
  • Intended Use: Use this device only for its intended purpose as a programmable time switch for electrical equipment.

3. Product Overview

The KG316T-II is a compact DIN rail mountable electronic timer. It features an LCD display for time and program settings, along with several control buttons for easy programming.

3.1 Components and Controls

Front and back view of the KG316T-II timer.
Front and back view of the KG316T-II Digital Programmable Timer. The back shows the DIN rail mounting clip.
Detailed view of the timer's buttons and LCD display with labels.
Detailed view of the timer's control panel and LCD display.
  • LCD Display: Shows current time, day, and ON/OFF status.
  • C/R Button: Reset timer's settings. (Press before programming)
  • D+ Button: Adjust day or week.
  • H+ Button: Adjust hour.
  • M+ Button: Adjust minute.
  • Clock Button (⏱): To adjust current day & time.
  • P Button: Programs review & setting programs.
  • MANUAL Button: Manual override for ON/OFF status.
  • LED Indicator: Indicates ON/OFF status.

4. Specifications

FeatureSpecification
ModelKG316T-II
MaterialABS
ColorWhite
Working VoltageAC 220V ± 15%
Frequency50~60Hz
Output Control25A 220V AC (Resistive Load)
ON/OFF Operation16 ON/OFF settings per day/week
Minimum Interval1 minute
Power Consumption≤2W
DisplayLCD
Error Correction1 sec/day (at 25℃)
Power Reserve60 days (via 1.2V 40mAh Lithium battery)
Ambient Temperature-10~+40℃
Ambient Humidity35~85% RH
Item Dimensions (L*W*H)9.8 x 5.5 x 4.0 cm (3.85 x 2.16 x 1.57 in)
Package Weight145g / 5.11oz
CertificationCE
Dimensions of the KG316T-II timer.
Size display of the KG316T-II timer with approximate dimensions.

5. Installation

The KG316T-II is designed for DIN rail mounting. Ensure power is disconnected before proceeding with installation.

5.1 Mounting

  1. Locate a suitable DIN rail within your electrical enclosure.
  2. Align the timer's DIN rail clip (on the back) with the DIN rail.
  3. Press the timer firmly onto the rail until it clicks into place, ensuring it is securely fastened.

5.2 Wiring Diagram

Refer to the diagram below for correct wiring. All wiring must comply with local electrical codes and regulations.

Wiring diagram for the KG316T-II timer switch.
Wiring diagram for the KG316T-II Timer Switch. Terminals 1 and 2 are for Power input, and terminals 3 and 4 are for Load output.
  • Power Input: Connect the AC 220V power supply to terminals 1 and 2.
  • Load Output: Connect the electrical equipment (load) to be controlled to terminals 3 and 4.
  • Ensure all connections are tight and secure.

6. Operating Instructions

The timer allows for precise scheduling of electrical devices. Follow these steps to set up and program your timer.

6.1 Initial Setup (First Use or After Power Loss)

  1. Reset: Press the C/R button to clear all previous settings and reset the timer. The display will show '00:00'.
  2. Set Current Time:
    • Press and hold the Clock (⏱) button.
    • While holding Clock (⏱), press D+ to set the current day of the week.
    • While holding Clock (⏱), press H+ to set the current hour.
    • While holding Clock (⏱), press M+ to set the current minute.
  3. Release the Clock (⏱) button. The current time and day are now set.

6.2 Programming ON/OFF Events

The timer supports up to 16 ON/OFF settings. Each setting can be applied to specific days or combinations of days.

  1. Press the P button once. The display will show '1 ON' (for the first ON event).
  2. Press D+ to select the desired day(s) for this ON event. You can cycle through individual days, weekdays, weekends, or various combinations (refer to the '15-combination of daily-programs' table below).
  3. Press H+ to set the hour for the ON event.
  4. Press M+ to set the minute for the ON event.
  5. Press the P button again. The display will show '1 OFF' (for the first OFF event).
  6. Repeat steps 2-4 to set the day(s), hour, and minute for the OFF event.
  7. Continue pressing P to cycle through '2 ON', '2 OFF', up to '16 ON', '16 OFF', setting each event as needed.
  8. After setting all desired programs, press the Clock (⏱) button to exit programming mode and return to the current time display.
Diagram showing 16 ON/OFF events and 15 daily program combinations.
Diagram illustrating the concept of 16 ON/OFF events per day/week and a table detailing the 15 combinations of daily programs for scheduling.

6.3 Manual Override

Press the MANUAL button to temporarily change the timer's output status without affecting the programmed schedule. Each press will cycle through ON, AUTO, and OFF modes.

  • ON: Output is continuously ON.
  • OFF: Output is continuously OFF.
  • AUTO: Timer operates according to the programmed schedule.

7. User Tips

  • Energy Saving: Utilize the programmable features to turn off lights or appliances when not in use, such as during work hours or overnight.
  • Pre-programming: It's often easier to plan out your ON/OFF schedule on paper before attempting to program the timer.
  • Battery Backup: The internal lithium battery ensures your settings are retained for up to 60 days during power outages, so you won't lose your programs.
  • Versatile Use: This timer is suitable for a wide range of applications, from simple household appliance control to more complex industrial automation tasks.

8. Troubleshooting

If you encounter issues with your timer, try the following common solutions:

  • Timer not turning ON/OFF:
    • Check if the timer is in 'AUTO' mode. If it's in 'ON' or 'OFF' manual mode, it will override the program.
    • Verify that the power supply to the timer is active.
    • Ensure the programmed ON/OFF times and days are correctly set.
  • Display is blank or erratic:
    • Check the power supply.
    • Press the C/R button to reset the timer. You may need to re-enter all settings.
  • Settings are lost after power outage:
    • While the timer has a power reserve, prolonged outages beyond 60 days or a depleted internal battery can cause settings to be lost. Recharge the battery by keeping the timer powered for several hours.
  • Load not receiving power:
    • Check the wiring connections to the load (terminals 3 and 4).
    • Ensure the load itself is functional.
    • Verify the load does not exceed the timer's maximum contact capacity (25A 220V AC).

9. Maintenance

The KG316T-II Digital Programmable Timer requires minimal maintenance to ensure long-term reliable operation.

  • Cleaning: Periodically wipe the exterior of the timer with a soft, dry cloth. Do not use abrasive cleaners, solvents, or excessive moisture, as these can damage the device.
  • Inspection: Regularly inspect the wiring connections to ensure they remain tight and free from corrosion. Check for any signs of physical damage to the casing or terminals.
  • Environment: Ensure the operating environment remains within the specified ambient temperature and humidity ranges to prevent premature wear or malfunction.
  • Battery: The internal lithium battery is designed for long life and typically does not require replacement. Keeping the timer powered will ensure the battery remains charged for power reserve functionality.

10. Warranty and Support

KKMOON Directsale Store is committed to providing high-quality products. This product is covered by a warranty against manufacturing defects.

  • Quality Assurance: We strictly control product quality before shipping. In the event of any quality problem, you may return the product in its original condition for repair or exchange.
  • Transit Damage: If the product is damaged during transit, please contact us immediately upon receipt. We will assist in resolving the issue.

For further assistance, technical support, or warranty claims, please contact the KKMOON Directsale Store directly through your purchase platform.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.