1. Introduction

This manual provides detailed instructions for the safe and efficient operation, installation, and maintenance of your Jikong Smart BMS B1A8S20P-HC. Please read this manual thoroughly before using the device and keep it for future reference.

Product Overview

The Jikong Smart BMS B1A8S20P-HC is an advanced Battery Management System designed for Li-Ion, LiFePo4, and LTO battery packs ranging from 4S to 8S configurations. It features active balancing, Bluetooth connectivity, RS485 and CAN communication, and a heating function. With a continuous output current of 200A, it is suitable for various applications including power BMS, energy storage, and 3C digital devices.

Main product view of the Jikong Smart BMS B1A8S20P-HC
Main product view of the Jikong Smart BMS B1A8S20P-HC, highlighting its compact design and key features.
Product overview video showcasing the Jikong Smart BMS and its features.

2. Specifications

FeatureDetail
Brand Namejikong
Handware or SmartSMART BMS
TypeLI-ION Battery BMS
Battery Strings4S-8S
Battery TypeLi-ion/LiFePo4/LTO
Charging Current200A
Balance FunctionActive Balanced BMS
Charge and Discharge PortCommon Port BMS
FunctionOvercharge Protection, Over Discharge Protection, Overcurrent Protection, Short Circuit Protection
Temperature sensorYes
Active BalanceYes
Heating functionYes
CommunicationRS485/BT
Usage ScenarioPower BMS, Energy Storage BMS, 3C Digital BMS
CertificationCE, FCC, RoHS
High-concerned chemicalNone

Dimensions and Weight

  • Length: 20 cm
  • Width: 15 cm
  • Height: 5 cm
  • Weight: 0.55 kg

3. Safety Information

Always observe the following safety precautions to prevent injury or damage to the device and connected battery systems.

  • Ensure proper ventilation to prevent overheating.
  • Do not expose the device to moisture, corrosive environments, or extreme temperatures outside its operating range.
  • Handle with care to avoid physical damage to the BMS and its components.
  • Refer to the provided wiring diagrams for correct and safe connections. Incorrect wiring can lead to severe damage or fire.
  • Only qualified personnel should perform installation and maintenance.

Six Security Protections

Diagram showing six security protections for battery management
The BMS provides six key security protections: Overcharge Protection (prevents over-charging affecting battery life), Short Circuit Protection (automatic protection), Overcharge Protection (prevents battery from running out), Over Current Protection (prevents current from exceeding battery range), ALL-IN Protection (prevents cable drop or poor contact), and Over Temperature Protection (prevents battery from overheating).

4. Setup and Installation

Package Contents

Contents of the Smart BMS package including BMS unit, manual, screws, NTC, heating cable, CAN cable, switch, and wires.
The package typically includes the Smart BMS unit, an operation manual, 4 screws, an NTC (40cm), a heating cable (16cm), a CAN cable (25cm), a switch (50cm), and a set of wires (70cm).

BMS Connection Points

Detailed view of the BMS connections for temperature sensor, other functions, LCD, RS485, and Heat Function.
Connection points on the BMS: Temperature sensor, Other functions (customized), LCD (by default), RS485 (by default), and Heat Function (needs customization).

Wiring Diagram

Wiring diagram for the Smart BMS showing connections for NTC, CAN/RS485, GPS, Display, Heating Cable, Switch, 4.3 inch LCD, and 2.0 inch LCD.
Comprehensive wiring diagram illustrating connections for NTC, CAN/RS485, GPS, Display, Heating Cable, Switch, and optional LCD displays (4.3" and 2.0").

Installation Steps

  1. Connect the protection board and battery pack according to the provided wiring diagram.
  2. Ensure that the last power cord (B+) is connected to the main positive pole of the battery.
  3. The total voltage of the battery pack must be greater than 20V (Default BMS) or 10V (4S BMS) before starting up.
  4. Use the display activation button or an additional switch to activate the BMS.

5. Operation

Smart BT APP Connection

Screenshots of the Smart BT APP interface for monitoring and controlling the BMS.
The Smart BT APP allows real-time monitoring of battery data, modification of related parameters, and control of the BMS balance switch. It supports both Android and iOS systems.

To connect your BMS to the Smart BT APP:

  1. Download the APP: Search for "JIKONG BMS" in the APP STORE (iOS) or "JK BMS" in the Google STORE (Android).
  2. Turn on GPS and Bluetooth on your mobile phone.
  3. Ensure your mobile Bluetooth is active, then open the APP.
  4. Click on the top left corner of the APP to search for devices.
  5. Click on the device name to connect. The default password is 1234.

Initial Setup via APP

For the first start-up, parameters need to be configured:

  1. Access the parameter settings. This requires a password. The default parameter setting password is 123456.
  2. Set the number of units (battery strings) and the battery type (Li-ion/LiFePo4/LTO) to match your battery pack.
  3. Once parameters are set, navigate back to the real-time status page.
  4. Check the battery status; ensure no error message is prompted and normal operation is indicated. Blue indicates the highest voltage, red indicates the lowest voltage.

Smart Energy Working Modes

Diagram illustrating the smart energy working modes: Storage Mode, Normal Working Mode, Standby Mode, and Shutdown.
The BMS supports various working modes: Storage Mode (for transportation/offline, consumes no battery current), Normal Working Mode (activated by charger, all protections and functions return to normal), Standby Mode (entered after a set time of inactivity, 1-30 days), and Shutdown (automatic shutdown below a cell's shutdown voltage to prevent damage).

6. Maintenance

To ensure the longevity and optimal performance of your Jikong Smart BMS, follow these maintenance guidelines:

  • Regularly check all cable connections for tightness and corrosion. Loose connections can lead to inaccurate readings or system failure.
  • Keep the BMS clean and free from dust, moisture, and debris. Use a dry, soft cloth for cleaning.
  • Monitor battery parameters via the Smart BT APP for any anomalies or unexpected behavior. Address warnings promptly.
  • Ensure the BMS is operated within its specified temperature range to prevent damage to internal components.
  • Periodically check for firmware updates through the official Jikong BMS channels to benefit from improved features and bug fixes.

7. Troubleshooting

Device does not turn on:
  • Ensure that the last B+ line of the cable has been correctly connected to the positive pole of the battery.
  • Start up after charging and ensure that the charger voltage is greater than 4V of the battery pack voltage.
  • Check whether the charger has voltage output.
Inaccurate voltage readings:
  • Measure the actual total pressure of the battery pack with a multimeter.
  • Fill the actual total pressure in the "voltage calibration" section on the parameter setting page within the APP.
Inaccurate current readings:
  • The B- and P- of the protection board are two 7AWG wires; both need to be connected in parallel. Failure to do so will lead to current errors.
  • Measure the actual current of the battery pack with a clamp meter.
  • Fill the actual current into the "current calibration" section on the parameter setting page in the APP. The larger the actual current, the higher the calibration accuracy.
Inaccurate capacity readings:
  • An initial capacity estimated according to the monomer voltage when the protection board is powered on for the first time may be inaccurate.
  • After the protection board is discharged to the cut-off voltage and then fully charged, the capacity is calibrated. The charging process cannot be interrupted during this calibration.
Designed string number inconsistent with actual string number:
  • Check whether the "unit quantity" in the parameter setting is set correctly in the APP.
  • If there is no voltage in two or more strings in the middle, check whether the acquisition cable has fallen off or is damaged.

8. User Tips

  • Always double-check all wiring connections against the diagram before applying power to prevent damage to the BMS or battery pack.
  • Utilize the mobile app for real-time monitoring and fine-tuning of parameters. This allows for optimal battery performance and early detection of potential issues.
  • For the most accurate capacity readings, perform a full discharge to the cut-off voltage followed by a complete charge cycle without interruption for calibration.
  • Keep the firmware updated to ensure you have the latest features and stability improvements.
  • If using the heating function, ensure proper insulation and monitoring to prevent excessive heat buildup.

9. Warranty and Support

For warranty information and technical support, please refer to the official Jikong BMS website or contact your authorized retailer. Keep your purchase receipt as proof of purchase.

Product certification: JIKONG BMS has RoHS, FCC, and CE certifications, ensuring compliance with international quality and safety standards.

Image showing product certifications: RoHS, FCC, CE.
Jikong BMS products are certified with RoHS, FCC, and CE standards, ensuring quality and safety compliance.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.