ZEEWEII DSO3D12

Contents

ZEEWEII DSO3D12 3-In-1 Signal Generator, Oscilloscope, and Multimeter User Manual

Model: DSO3D12 | Brand: ZEEWEII

1. Introduction

The ZEEWEII DSO3D12 is a compact and powerful 3-in-1 device designed for a wide array of electronic testing and measurement tasks. It integrates a 120M bandwidth dual-channel digital oscilloscope, a high-accuracy true RMS multimeter, and a 2.5V signal generator into a single portable unit. Built with ARM and FPGA chip collocation, it offers high-speed signal acquisition and data processing, ensuring a smooth user experience across its rich functionalities. This device is ideal for basic R&D, education, car maintenance, home appliance repair, DIY debugging, electronic competitions, power supply debugging, and frequency converter applications.

2. Key Features

  • 3-in-1 Functionality: Combines a digital oscilloscope, true RMS multimeter, and signal generator.
  • High Performance Oscilloscope: 120M bandwidth (CH1 only), 60M dual-channel mode, 500M equivalent sampling rate, 250M real-time sampling rate, <3ns rise time.
  • Integrated Multimeter: Measures voltage, current, resistance, diode, continuity, and capacitance with high accuracy. Features isolation between oscilloscope and multimeter for safe high-voltage measurements.
  • Signal Generator: Outputs sine, square, triangle, half, and singh waves with 2.5V amplitude and adjustable frequency from 0-2MHz. Square wave duty cycle adjustable from 1% to 99%.
  • User-Friendly Display: 3.2-inch high-definition IPS display with full viewing angle. Channel 2 waveforms can be displayed in green, cyan, or purple.
  • Advanced Measurement Features: Supports XY mode, persistence, FFT (Fast Fourier Transform) for frequency analysis, single trigger, and fully automatic measurement modes.
  • Waveform Management: One-click waveform save and view, with the ability to browse and delete stored waveforms.
  • Portable Design: Compact size with a collapsible stand for convenience.

3. Package Contents and Setup

3.1 Package List

Upon opening the package, please verify that all items are present and in good condition:

  • ZEEWEII DSO3D12 3-in-1 Device
  • Oscilloscope Probes (x2)
  • Multimeter Test Leads (x2)
  • USB Type-C Charging Cable
  • Small accessories (e.g., probe adjustment tool, color rings for probes)
ZEEWEII DSO3D12 with included accessories: oscilloscope probes, multimeter leads, and USB-C cable.
Figure 3.1: ZEEWEII DSO3D12 and its accessories.

3.2 Initial Setup and Charging

  1. Unpack: Carefully remove the device and all accessories from the packaging.
  2. Inspect: Check for any visible damage to the device or accessories.
  3. Charge: Connect the device to a 5V power source using the provided USB Type-C cable. The battery typically takes about 6 hours to fully charge.
  4. Stand: The device features a collapsible stand at the back for convenient benchtop use. Extend it as needed.

4. Operating Instructions

4.1 General Controls

The DSO3D12 features a user-friendly interface with a 3.2-inch display and a set of buttons for navigation and function control. Key buttons include:

  • Navigation Buttons (Up, Down, Left, Right, OK): Used to navigate menus and adjust parameters.
  • Auto2 / Auto: One-key automatic adjustment for oscilloscope waveforms.
  • Zoom: Magnifies the displayed waveform.
  • Stop: Pauses the waveform acquisition.
  • Ref: Activates reference waveform display.
  • Single: Sets the oscilloscope to single trigger mode.
  • AC/DC: Toggles AC/DC coupling for the selected channel.
  • CH1 / CH2: Selects Channel 1 or Channel 2 for adjustments.
  • X1x10: Adjusts probe attenuation setting.
  • Gen: Activates the signal generator function.
  • Save: Saves the current waveform or screenshot.
  • View: Accesses saved waveforms/screenshots.
  • Shift: Used in combination with other buttons for secondary functions.
  • 50%: Sets trigger level to 50%.
  • DMM Select: Switches to multimeter mode and selects measurement type.
  • mV / V: Adjusts vertical sensitivity (voltage per division).
  • Time base / ns: Adjusts horizontal time base (time per division).
  • CurX / CurY: Activates X or Y cursor measurements.

4.2 Oscilloscope Mode

The oscilloscope function allows for visualization and analysis of electrical signals.

Video 4.1: Demonstration of various oscilloscope functions including time base, vertical sensitivity, roll mode, single trigger, dual channel, XY mode, persistence, signal generator, FFT, and zoom.

4.2.1 Basic Waveform Display

Connect the oscilloscope probes to the BNC inputs (CH1 and CH2) and to the circuit under test. Use the Time base and mV/V buttons to adjust the horizontal and vertical scales respectively. The Auto button can quickly set optimal display parameters.

4.2.2 Dual Channel Mode

When Channel 2 is activated, the device operates in dual-channel mode, allowing simultaneous measurement and display of two signal waveforms. This is useful for comparative analysis, observing phase differences, or analyzing complementary PWM signals.

Image showing the DSO3D12 in dual channel mode, displaying two distinct waveforms on the screen.
Figure 4.2: Dual channel display showing two waveforms.

4.2.3 XY Mode

XY mode combines the waveforms of two channels to form an image, commonly used to observe Lissajous figures, which can indicate phase differences and frequency ratios between two signals.

Four examples of Lissajous figures displayed on the oscilloscope screen in XY mode.
Figure 4.3: Examples of XY mode displays (Lissajous figures).

4.2.4 Persistence

Persistence mode allows you to view the history of a waveform, showing how it changes over time. This is particularly useful for observing infrequent events or signal variations.

Oscilloscope screen showing a waveform with persistence, where older traces fade out, revealing signal variations.
Figure 4.4: Waveform display with persistence enabled.

4.2.5 FFT Spectrum

The Fast Fourier Transform (FFT) function converts waveforms from the time domain to the frequency domain, allowing you to analyze the frequency components of a signal. It supports linear and logarithmic displays. Note that FFT can only display spectrograms; direct frequency measurement is not supported.

Oscilloscope screen displaying an FFT spectrum, showing frequency components of a square wave.
Figure 4.5: FFT Spectrum analysis of a waveform.

4.2.6 Trigger System

The DSO3D12 offers Auto, Normal, and Single trigger modes. You can set the trigger type to Rise or Fall, adjust the trigger level manually or automatically, and select the trigger source from CH1 or CH2.

Oscilloscope screen showing trigger settings menu with options for trigger type, level, and source.
Figure 4.6: Perfect Trigger settings for stable waveform capture.

4.2.7 Cursor Measurement

The device supports X and Y cursor measurements. The horizontal (X) cursor can measure the time interval between two pulses, while the vertical (Y) cursor can measure the voltage and voltage difference at any two locations on the waveform.

A hand interacting with the oscilloscope screen, demonstrating X and Y cursor measurements on a waveform.
Figure 4.7: Cursor measurement in action.

4.2.8 Fully Automatic Mode

The DSO3D12 supports one-key automatic and fully automatic modes. Simply click the Auto button to perform waveform detection and display. This eliminates complicated operations, allowing for quick waveform adjustment, especially beneficial for beginners.

Oscilloscope screen displaying a waveform after automatic adjustment, highlighting the ease of use.
Figure 4.8: Fully automatic waveform adjustment.

4.2.9 Waveform Save/View

You can save the screen waveform with one click. Enter the picture browsing page to view thumbnails or full-screen observations. Unwanted waveform charts can be deleted at will.

Oscilloscope screen showing a gallery of saved waveforms in thumbnail view.
Figure 4.9: Waveform Save/View interface.

4.2.10 Reference Waveform

The reference waveform feature allows you to latch a current waveform on the screen while dynamic waveforms continue to refresh normally. This is useful for reference and comparison between multiple waveforms.

Oscilloscope screen displaying a static reference waveform alongside a live, changing waveform.
Figure 4.10: Reference waveform for comparison.

4.2.11 Display Customization

The 3.2-inch HD IPS display offers a clear view. Channel 2 waveforms can be customized to display in green, cyan, or purple for better differentiation.

Close-up of the 3.2-inch HD IPS display showing a clear waveform.
Figure 4.11: HD IPS display clarity.

4.3 Multimeter Mode

The built-in high-precision true RMS multimeter supports fast software calibration and can measure various electrical parameters.

DSO3D12 displaying a voltage measurement in multimeter mode.
Figure 4.12: High-precision multimeter displaying voltage.

4.3.1 Measurements

The multimeter can measure:

  • DC Voltage
  • AC Voltage
  • DC Current
  • AC Current
  • Resistance
  • Capacitance
  • Diode
  • Continuity

When measuring low voltage, resistance, or continuity, the oscilloscope and multimeter can be used simultaneously, with the multimeter reading displayed in a small window in the upper right corner.

DSO3D12 showing multimeter resistance measurement while an oscilloscope waveform is also visible.
Figure 4.13: Multimeter function with simultaneous oscilloscope display.

4.3.2 Safety Feature: Isolation

The multimeter is isolated from the oscilloscope using an isolation transformer and optocoupler chip. This design ensures safety when measuring high voltages, as the multimeter and oscilloscope can be used independently without common ground concerns.

Diagram illustrating the safe isolation design between the oscilloscope and multimeter functions.
Figure 4.14: Safe design with isolation for multimeter measurements.

4.4 Signal Generator Mode

The built-in waveform signal generator can output various waveforms with adjustable parameters.

DSO3D12 screen showing the signal generator interface with waveform type and frequency settings.
Figure 4.15: Signal generator interface.

4.4.1 Waveform Output

The generator can output sine wave, square wave, triangle wave, half wave, and singh waves. The voltage amplitude is fixed at 2.5V. The frequency is adjustable from 0 to 2MHz. For square waves, the duty cycle is adjustable from 1% to 99%.

5. Specifications

5.1 General Specifications

FeatureSpecification
Model NumberDSO3D12
Brand NameZEEWEII
Screen Size3.2 inches
Display TypeHD IPS
LanguageChinese / English
Key TypeSoft silicone keys
ChargingTYPE-C 5V
Battery TimeAbout 6 hours
Battery IncludedYes
IS Battery DemountableNo
Case Size14.5 * 8.6 * 3.2 cm
BracketCollapsible stand
CertificationCE
DIY SuppliesElectrical
OriginMainland China

5.2 Oscilloscope Parameters

ParameterSpecification
Channels2
Real-time Sample Rate250MSa/s
Bandwidth120MHz (CH1 Only), 60MHz (CH1+CH2)
Equivalent Sampling500M
Rise Time<3ns
Storage Depth128kb
Impedance1MΩ
Time Base5ns - 10s
Peak Voltage±40V (1x), ±400V (10x)
Trigger ModeAuto/Normal/Single
Trigger TypeRise/Fall
Display ModeYT/XY/Roll
PersistenceNone/1s/∞
CouplingAC/DC
Auto ModeOneKey-auto/Fully-auto
SensitivityX1:10mV/div~10V/div, X10:100mV/div~100V/div
Measure Items14 types (Frequency, P-eak to P-eak, Duty cycle, Amplitude, RMS, Average, Period, +Pulse width, -Pulse width, Max, Min, Top, Base, -Duty cycle)
DC Offset±2%
XY ModeYes
ScreenshotYes
Frequency Accuracy±0.01%
Zoom ModeYes
FFTYes

5.3 Multimeter Parameters

FunctionRangePrecision
DC Voltage600mV/6.00V/60.0V/600V/750V±(0.5%+3)
AC Voltage600mV/6.00V/60.0V/600V±(1%+3)
DC Current600mA / 10A±(2%+5)
AC Current600mA / 10A±(3%+5)
Resistance600.0Ω / 6.000kΩ / 60.00kΩ / 600.0kΩ / 6.000MΩ / 60.00MΩ±(1.5%+3) / ±(1%+3) / ±(1%+3) / ±(1%+3) / ±(1.5%+5) / ±(3%+3)
Capacitance60.00nF/600.0nF/6.000μF / 60.00μF/600.0μF±(5%+5) / ±(10%+5)
Diode0.0V~3.3V, 3.3V higher display OL
ContinuitySound at 50Ω and below

Current Note: 600mA hole with 1A fuse, 10A hole without fuse.

5.4 Signal Generator Parameters

ParameterSpecification
Generator Wave TypesSine/Square/Triangle/Half/Singh waves
Generator Voltage Amplitude2.5V ±0.05
Generator Frequency1Hz - 2MHz

6. Maintenance

To ensure the longevity and optimal performance of your ZEEWEII DSO3D12, please follow these maintenance guidelines:

  • Cleaning: Use a soft, dry cloth to clean the device. For stubborn dirt, a slightly damp cloth with mild detergent can be used, ensuring no liquid enters the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight, extreme temperatures, and high humidity.
  • Battery Care: For optimal battery life, avoid fully discharging the battery frequently. If storing for extended periods, charge the device to about 50-70% and recharge every few months.
  • Probe Care: Handle probes carefully. Avoid bending or stressing the cables excessively. Keep probe tips clean.
  • Avoid Impact: Protect the device from drops and impacts, which can damage internal components or the screen.

7. Troubleshooting

If you encounter issues with your ZEEWEII DSO3D12, please refer to the following common troubleshooting steps:

  • Device Not Turning On: Ensure the battery is charged. Connect the device to a power source using the USB Type-C cable and try again.
  • No Waveform Display: Check probe connections to both the device and the circuit. Ensure the input signal is within the device's voltage range. Try pressing the 'Auto' button to automatically adjust the display. Verify that the correct channel (CH1/CH2) is selected and enabled.
  • Incorrect Multimeter Readings: Ensure test leads are correctly inserted into the appropriate ports (e.g., VΩmA for voltage/resistance/current, COM for common). Select the correct measurement function (e.g., DCV, ACV, Resistance). Check for damaged test leads.
  • Signal Generator Not Outputting: Ensure the 'Gen' function is activated and parameters (frequency, waveform type) are set correctly. Check the connection from the signal generator output to the receiving circuit.
  • Screen Frozen/Unresponsive: Try restarting the device. If the issue persists, contact customer support.

For issues not covered here, please refer to the official product support channels.

8. Warranty and Support

The ZEEWEII DSO3D12 comes with a standard manufacturer's warranty. Please retain your proof of purchase for warranty claims. For detailed warranty terms, technical support, or service inquiries, please contact the seller or refer to the official ZEEWEII website.

This product is eligible for free returns within 90 days, as per AliExpress policy. For more information on returns and other services, please visit the AliExpress service promise page.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.