1. Safety Precautions
Thank you for choosing INKBIRD products. Please read this instruction manual carefully before use to ensure correct application and maintenance.
- Ensure the product is used within its specified parameters.
- Do not touch when electrified. Failure to do so may cause personal injury due to electric shock.
- Do not allow metal fragments, wire clippings, or fine metal shavings or filings to enter the product during installation. This may lead to electric shock, fire, or malfunction.
- Do not use this product in environments with flammable and explosive gases. This may result in explosive damage.
- Do not touch any internal parts while disassembling, modifying, or repairing the product. This may cause failure, electric shock, or fire.
If the output relays are used past their life expectancy, contact fusing or burning may occasionally occur. Always consider the application conditions and use the output relays within their rated load and electrical life expectancy. The life expectancy of output relays varies considerably with the output load and switch conditions.
2. Main Functions
The INKBIRD ITC-1000 Digital Temperature Controller offers the following key functionalities:
- Fahrenheit and Celsius display options.
- User-friendly operation.
- Ability to switch between cooling and heating modes.
- Temperature control by setting a target temperature value and a difference value.
- Temperature calibration feature.
- Refrigerating control output delay protection.
- Alarm activation when temperature exceeds set limits or in case of sensor error.
3. Specifications
3.1. General Specifications
| Parameter | Value |
|---|---|
| Temperature Measuring Range | -50~99°C / -50~210°F |
| Temperature Resolution | 0.1°C / 0.1°F |
| Measuring Accuracy | ±1°C (-50~70°C) / ±1°F (-50~160°F) |
| Power Supply | 110Vac/220Vac 50Hz/60Hz, 12Vdc |
| Power Consumption | <3W |
| Sensor Type | NTC Sensor (Included) |
| Sensor Length | 2m (including the probe) |
| Relay Contact Capacity | Cooling (10A/250VAC) / Heating (10A/250VAC) |
| Ambient Temperature | 0°C~60°C |
| Storage Temperature | -30°C~75°C |
| Relative Humidity | 20-85% (No Condensate) |
3.2. Dimensions
- Front Panel Size: 75(L)*34.5(W)mm
- Mounting Size: 71(L)*29(W)mm
- Product Size: 75(L)*34.5(W)*85(D)mm

4. Panel Instruction

- Power Key (A): Power On and Off, Confirm the Setting Value, Save and Exit Function.
- Up Key (B): Choose Parameter, Increase Value and Check the Setting Temperature Value.
- Down Key (C): Choose Parameter, Decrease Value and Check the Setting Difference Value.
- Set Key (D): Entry, Exit and Set Parameters.
- Setting Indicator Lamp (E): On: Setting Status.
- PV/SV Display (F): Displays Process Value, Set Value and Parameter Menu.
- Cool Indicator Lamp (G): On: Refrigerating Start; Off: Refrigerating Stop; Flash: Compressor Delay.
- Heat Indicator Lamp (H): On: Heating Start; Off: Heating Stop.
5. Key Operating Instruction
5.1. Check Parameter
In normal working status:
- Press the "Up" key once to display the setting temperature value.
- Press the "Down" key once to display the difference value.
5.2. Parameter Setting
To enter the parameter setting mode:
- In normal working status, keep pressing the "S" key for more than 3 seconds. The set indicator lamp will turn on, and the screen will display the first menu code "TS".
- Press the "Up" or "Down" key to navigate through the menu items and display the menu codes.
- Press the "S" key to enter the parameter setting of the current menu. The parameter value will start to flash.
- Press the "Up" or "Down" key to adjust the parameter value of the current menu.
- After setting, press the "S" key to exit the parameter setting of the current menu. The parameter value will stop flashing. You can set other functions by following the steps above.
- In any status, press the "Power" key to save the modified parameter value and return to the normal temperature display. If no operation is performed within 10 seconds, the menu will automatically exit and return to normal temperature display status, without saving the modification.
6. Operating Instruction
- Turning On/Off: In normal working status, press and hold the "Power" key for more than 3 seconds to turn off the controller. In power-off status, press and hold the "Power" key for more than 1 second to turn on the controller.
- Automatic Mode Switching: In normal working status, the screen displays the current measured value. The controller automatically switches between heating and cooling modes.
- Refrigerating Operation: If the measured temperature is greater than or equal to (temperature set value + difference set value), the controller starts refrigerating. The cool indicator lamp lights up, and the refrigerating relay is connected. When the cool indicator lamp flashes, it indicates that the refrigerating device is under compressor delay protection status.
- Refrigerating Stop: If the measured temperature is less than or equal to the temperature set value, the cool indicator lamp turns off, and the refrigerating relay is disconnected.
- Heating Operation: If the measured temperature is less than or equal to (temperature set value - difference set value), the controller starts heating. The heat indicator lamp lights up, and the heating relay is connected.
- Heating Stop: If the measured temperature is greater than or equal to the temperature set value, the heat indicator lamp turns off, and the heating relay is disconnected.
7. Menu Instruction
7.1. When the set temperature is in Celsius (°C)
| Code | Function | Set Range | Default | Note |
|---|---|---|---|---|
| TS | Temperature Set Value | -50~99.9°C | 10.0°C | |
| DS | Difference Set Value | 0.3~15°C | 1.0°C | |
| PT | Compressor Delay | 0~10 minutes | 3 minutes | |
| CA | Temperature Calibration Value | -15°C~15°C | 0°C | |
| CF | Fahrenheit or Celsius Setting | C |
7.2. When the set temperature is in Fahrenheit (°F)
| Code | Function | Set Range | Default | Note |
|---|---|---|---|---|
| TS | Temperature Set Value | -50~210°F | 50°F | Min. Unit 1°F |
| DS | Difference Set Value | 1~30°F | 3°F | |
| PT | Compressor Delay | 0~10 minutes | 3 minutes | |
| CA | Temperature Calibration Value | -15~15°F | 0°F | |
| CF | Fahrenheit or Celsius Setting | F |
Note:
When the CF value changes, all set values will restore to their default values.
8. Wiring Diagram

Wiring Notes:
- Connect the positive ('+') power to terminal #1. Use another wire to connect terminal #1 to #5 and #7.
- Connect the negative ('-') of the power to terminal #2. Connect the positive ('+') of the cooling device to #6, and the positive ('+') of the heating device to #8.
- Connect the temperature probe to terminals #3 and #4.
9. Error Description
9.1. Sensor Error Alarm
When the temperature sensor circuit is short-circuited or open-circuited, the controller enters sensor error mode and closes all running statuses. The buzzer alarm sounds, and the screen displays "ER". Pressing any key will cancel the buzzer alarm, and the system will return to normal working status after the error is cleared.
9.2. Over-temperature Alarm
When the measured temperature exceeds the temperature measuring range, the controller enters over-temperature error alarm mode and closes all running statuses. The buzzer alarm sounds, and the screen displays "HL". Pressing any key will cancel the buzzer alarm, and the system will return to normal working status after the temperature returns to the measuring range.
10. Troubleshooting Guide
| Issue | Causes | Solutions |
|---|---|---|
| The probe reading is incorrect. |
|
|
| Cannot enter setting mode. |
|
|
11. User Tips
- Ensure heating and cooling devices are properly wired to the power supply to complete the circuit.
- If the cooling device doesn't start immediately and the cool indicator lamp flashes, consider setting the Compressor Delay (PT) to 0 if immediate operation is desired.
- This controller is noted by users for its stability and effectiveness across various applications.