1. Introduction
Thank you for choosing the VEVOR Electric Garage Heater. This manual provides important information regarding the safe installation, operation, and maintenance of your heater. Please read this manual thoroughly before installation and use, and keep it for future reference. This heater is designed to provide efficient and reliable heating for garages, workshops, and similar spaces.

2. Safety Information
WARNING: Failure to follow these safety instructions may result in fire, electric shock, injury, or property damage.
- Read all instructions before using this heater.
- This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains, at least 3 feet (0.9 meters) from the front of the heater and keep them away from the sides and rear.
- Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.
- Do not operate any heater with a damaged cord or plug or after the heater malfunctions, has been dropped or damaged in any manner. Discard heater, or return to authorized service facility for examination and/or repair.
- Do not use outdoors.
- This heater is not intended for use in bathrooms, laundry areas, and similar indoor locations. Never locate heater where it may fall into a bathtub or other water container.
- Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Arrange cord away from traffic area and where it will not be tripped over.
- To disconnect heater, turn controls to off, then remove plug from outlet.
- Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage the heater.
- To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, like a bed, where openings may become blocked.
- All electrical wiring must be performed by a qualified electrician and conform to all local and national electrical codes.
- This heater includes an overheat protection feature that automatically powers off the unit if the internal temperature exceeds 65°F (18°C) or a safe operating limit. If this occurs, disconnect the heater, allow it to cool, and check for any obstructions before restarting.
- The heater is ETL certified, ensuring compliance with safety standards.

3. Product Overview
Key Features
- High Power & Efficient Heating: Available in 5KW, 7.5KW, and 10KW models, covering areas up to 969 sqft (90 sqm).
- Precise Temperature Control: Intelligent thermostatic control maintains a consistent indoor temperature with a minimal 2°F difference. Temperature range: 45°F-99°F (7-37°C).
- Dual Safety Protection: Constructed from SPCC cold-rolled steel and equipped with automatic overheat power-off. ETL certified.
- Multi-Angle Adjustment: Flexible installation angles and adjustable louvers for precise air delivery and uniform heating.
- User-Friendly Operations: Digital control panel, remote control, 1-9 hour timer function, and a 3-minute post-shutdown fan delay for cooling.

Package Contents
Please check the package contents upon receipt:
- Electric Garage Heater Unit
- Remote Control
- Mounting Hardware (screws, washers, knobs)
- User Manual (this document)

4. Specifications
| Feature | 5KW Model (BGP2102-50R) | 7.5KW Model (BGP2102-75R) | 10KW Model (BGP2102-100R) |
|---|---|---|---|
| Brand | VEVOR | ||
| Material | Anti-flammable PC, Cold Rolled Steel Plate SPCC | ||
| Origin | Mainland China | ||
| Certification | CE, ETL Certified | ||
| Power | 5000W | 7500W | 10000W |
| Noise | ≤65 decibels | ≤68 decibels | |
| Airflow | 1069 m³/h | 1700 m³/h | |
| Heating Area | 538 sqft / 50 sqm | 969 sqft / 90 sqm | |
| Heating Levels | 3000W / 5000W | 7500W / 10000W | |
| Heating Element | AC240V 5000W | AC240V 7500W | AC240V 10000W |
| Timer Function | 1-9 hours | ||
| Safety Protection | Overheat Protection, Automatic Power-off | ||
| Control Method | Digital Control Panel, Remote Control | ||
| Item Weight | 20 lbs / 9.1 kg | 32 lbs / 14.5 kg | |
| Dimensions (H x W x D) | 324mm (12.7") x 325mm (12.7") x 270-271mm (10.6") | ||
5. Setup and Installation
IMPORTANT: All electrical wiring must be performed by a qualified electrician and conform to all local and national electrical codes.
5.1 Mounting Options
The VEVOR Electric Garage Heater can be installed as a wall-mounted or hanging unit to maximize indoor space utilization. Ensure the mounting surface is sturdy enough to support the heater's weight.
Minimum Clearance Requirements:
- From Ceiling: 8 inches (20 cm) minimum
- From Side Walls: 13 inches (33 cm) minimum
- From Floor: 72 inches (1.8 meters) minimum

5.2 Electrical Wiring
The heater requires a dedicated AC240V circuit. Refer to the wiring diagram below for proper electrical connection. Always ensure the power is disconnected at the breaker panel before beginning any wiring work.
- Remove the wiring cover on the heater to expose the internal wiring terminals.
- Connect the electrical supply wires (Black, Ground, White) to the corresponding terminals inside the heater.
- Securely replace the wiring box cover.

6. Operating Instructions
Your VEVOR Electric Garage Heater can be operated using the digital control panel on the unit or the included remote control.
6.1 Control Panel Overview
The control panel features a digital display and several buttons for power, mode, and temperature/timer adjustments.

6.2 Basic Operation
- Power On/Off: Press the power button on the control panel or remote to turn the heater on or off.
- Adjusting Temperature: The heater operates within a temperature range of 45°F-99°F (7-37°C). To set the desired temperature, press the MODE button twice, then use the up/down arrows to adjust. The display shows the inlet temperature.
- Selecting Heating Levels: The heater offers two adjustable power levels (e.g., 7500W/10000W for the 10KW model). Use the mode button or specific buttons on the remote (if available) to cycle through these settings.
- Timer Function: Set the heater to operate for a duration between 1 and 9 hours. Consult the full manual for detailed timer setting instructions.
- Automatic Fan Delay: After turning off the heater, the fan will continue to run for approximately 3 minutes to cool down the heating elements and prolong the unit's lifespan.
6.3 Remote Control
The included remote control allows for convenient operation from a distance. It typically includes buttons for Power, Mode, and Temperature/Timer adjustments. Ensure the remote has working batteries and is pointed towards the heater's receiver.
7. Maintenance
WARNING: Always disconnect power to the heater before performing any maintenance or cleaning.
- Cleaning: Regularly wipe the exterior of the heater with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Air Vents: Ensure that the air intake and exhaust vents are clear of dust, debris, and obstructions. Use a vacuum cleaner with a brush attachment to gently clean the vents.
- Internal Inspection: Periodically, and especially before seasonal use, have a qualified technician inspect the internal components and electrical connections for wear or damage.
- Storage: If storing the heater for an extended period, ensure it is clean and dry. Store it in a cool, dry place away from direct sunlight and moisture.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Heater does not turn on. | No power supply. Circuit breaker tripped. Power button not pressed. | Check power connection. Reset circuit breaker. Press the power button on the unit or remote. |
| Heater turns off unexpectedly. | Overheat protection activated. Timer function expired. | Disconnect power, allow to cool, check for obstructions, then restart. Check timer settings. |
| Heater not producing enough heat. | Incorrect heating level selected. Room size too large for heater capacity. Air vents blocked. | Adjust to a higher heating level. Ensure heater capacity matches room size. Clear any obstructions from air vents. |
| Remote control not working. | Dead batteries. Obstruction between remote and heater. | Replace batteries. Ensure clear line of sight to the heater's receiver. |
9. User Tips
- For optimal heating efficiency, ensure your garage or workspace is adequately insulated.
- Utilize the timer function to pre-heat your space before you arrive or to turn off the heater automatically after you leave, saving energy.
- Experiment with different mounting angles and louver adjustments to find the most effective heat distribution for your specific layout.
- Regularly check and clean the air vents to maintain optimal performance and prevent overheating.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact VEVOR customer service through their official website or the contact information provided at the time of purchase. Please have your model number and purchase date ready when contacting support.