yieryi LS310-2

Contents

yieryi LS310-2 6-in-1 Water Quality Tester User Manual

Model: LS310-2

1. Product Introduction

The yieryi LS310-2 is a versatile water quality meter designed for comprehensive analysis of various water types, including tap water, purified water, bottled water, ground water, and surface water (non-sewage). It measures six key parameters to provide a thorough assessment of water safety and quality.

The instrument utilizes ultraviolet absorption spectrophotometry to measure Chemical Oxygen Demand (COD), Total Organic Carbon (TOC), and UV275 (Ultraviolet Absorption Value). It also measures electrical conductance between electrodes to determine Total Dissolved Solids (TDS) and Electrical Conductivity (EC). Additionally, it includes a temperature sensor for accurate readings.

A key feature of the LS310-2 is its intelligent scoring system, which evaluates water quality based on the test results. The LCD backlight color changes to indicate four distinct water quality levels: Fine (blue), Good (green), Average (yellow), and Poor (red). The device also incorporates ambient temperature compensation for stable and accurate readings, and supports long-term calibration.

Its small, portable, pen-like design makes it simple to use and carry for various testing scenarios.

yieryi LS310-2 6-in-1 Water Quality Tester front view
Front view of the yieryi LS310-2 6-in-1 Water Quality Tester.
Diagram showing the 6 indicators measured by the water quality tester
The LS310-2 measures 6 indicators for comprehensive water quality assessment: EC, TOC, TDS, COD, UV275, and Temperature.

2. Specifications

ParameterDetails
Measurement ObjectTap water, purified water, bottled water, ground water, surface water (non-sewage), and other drinking water
Measurement ParametersCOD (Chemical Oxygen Demand), TOC (Total Organic Carbon), UV275 (Ultraviolet Absorption Value), TDS (Total Dissolved Solids), Electrical Conductivity, Temperature
COD Range0-100 mg/L
TOC Range0-100 mg/L
UV275 Range0-1.0 au/cm
TDS Range0-2000 ppm
EC Range0-4000 us/cm
Temperature Range0-50°C
COD Resolution0.01 mg/L
TOC Resolution0.01 mg/L
UV275 Resolution0.001 au/cm
TDS Resolution1 ppm
EC Resolution1 us/cm
Temperature Resolution0.1°C
COD Accuracy0-5mg/L: ±0.5mg/L; 5-100mg/L: ±10%H
TOC Accuracy0-5mg/L: ±0.5mg/L; 5-100mg/L: ±10%H
UV275 Accuracy0-0.1au/cm: ±0.01au/cm; 0.1-1.0au/cm: ±10%H
TDS Accuracy±3% FS (Full Scale)
EC Accuracy±3% FS (Full Scale)
Temperature Accuracy±1°C
Display240*135 1.14 inch TFT color screen
Power Supply2 x AAA alkaline dry batteries (Not included)
Size157 x 37 x 14 mm
WeightAbout 68g
Working Temperature Range0-50°C
Storage Temperature Range-10-60°C, 0-85%RH (no condensation)
Supply VoltageDC3V
Operating Current20mA
Operating Power Consumption60mW
Diagram showing the dimensions and labeled parts of the water quality tester
Product dimensions and labeled components: Battery compartment, color backlit display, measurement key, ON/OFF key, and high precision probes.

3. Features

  • Comprehensive Measurement: Simultaneously measures 6 parameters (COD, TOC, UV275, TDS, Electrical Conductivity, and Temperature) for a complete water quality evaluation.
  • Intelligent Color Display: Features a color screen display where the backlight color indicates different water quality levels (Fine, Good, Average, Poor) and provides a score.
  • Temperature Compensation & Calibration: Includes ambient temperature compensation for stable readings and supports long-term calibration for accuracy.
  • Portable Design: Small, pen-like design for easy handling and portability.
  • High Precision: Equipped with highly sensitive probes for rapid response and accurate data.
  • User-Friendly: One-button operation for quick and easy measurements.
Product details highlighting HD color display, sensitive probes, and battery compartment
Key product details: High Definition Colour Display for clear readings, highly sensitive probes for accuracy, and a battery compartment for 2*AAA batteries.

4. Setup

4.1. Power On/Off

Power On: Short press the Power button icon button. The version and serial number of the instrument will be displayed, then it will enter the measurement interface.

Power Off: Long press the Power button icon button to shut down the tester. The device will also automatically shut down if no operation is performed within 3 minutes.

4.2. Language Selection

  1. In the off state, press and hold the Power button icon button for 3 seconds to enter the Main Menu.
  2. Briefly press the Measurement button icon button to select 'Language'.
  3. Press the Power button icon button to enter the language option.
  4. Use the Measurement button icon button to select the desired language (e.g., English).
  5. Press the Power button icon button to confirm your selection.

4.3. Calibration

The instrument must be calibrated when used for the first time or after a long period of inactivity. Use purified water (bottled purified water labeled "Purified Drinking Water") for calibration. Do not use mineral or natural drinking water.

  1. In measuring mode, long press the Measurement button icon button to enter the calibration interface. Alternatively, from the Main Menu, select 'Calibration'.
  2. On the calibration interface, short press the Power button icon button to select [Yes/No] for calibration.
  3. Short press the Measurement button icon button to confirm the selection.
  4. Insert the probe of the instrument into pure water and short press the Measurement button icon button to start calibration.
  5. Once calibration is complete, the display will show "Calibration successful!" and return to the measurement page.

5. Operation

5.1. Taking a Measurement

  1. Ensure the device is powered on and calibrated.
  2. Insert the instrument's probe into the water sample to be tested, ensuring the water level reaches the "Lowest water mark" indicated on the device.
  3. Short press the Measurement button icon button to initiate the measurement.
  4. The display will show the measurement results for COD, TOC, TDS, EC, UV275, and Temperature.
  5. The backlight color will indicate the water quality level based on the scoring judgment.

5.2. Water Quality Scoring Judgment

The instrument grades water quality based on test results, with corresponding backlight colors:

  • Excellent: Blue backlight (Score 90-100)
  • Good: Green backlight (Score 80-90)
  • Average: Yellow backlight (Score 60-80)
  • Poor: Red backlight (Score 0-60)
ParameterFine (90-100)Good (80-90)Average (60-80)Poor (0-60)
COD (mg/L)0-0.750.75-1.51.5-33-7.5
TOC (mg/L)0-1.251.25-2.52.5-5.05.0-12.5
TDS (ppm)0-250250-500500-10001000-2000
TDS in PPM chart showing water quality levels
TDS in PPM chart: The lower the TDS value, the higher the purity. Generally, TDS 40 or less indicates safe drinking water.
Intelligent scoring function with examples of water quality levels
Intelligent scoring function indicates 4 different levels of water quality: Excellent (90-100), Good (80-90), Average (60-80), and Poor (0-60).

5.3. Residual Chlorine Detection

The UV275 indicator indirectly reflects the residual chlorine content in water. A higher UV275 value indicates a higher residual chlorine content.

Video demonstrating the difference between a standard TDS tester and the LS310 water quality tester in detecting residual chlorine. The LS310 provides a more comprehensive assessment.
Image demonstrating residual chlorine content measurement with UV275 indicator
Measurement of residual chlorine content in water using the UV275 indicator.

5.4. Multiple Test Scenarios

The LS310-2 is suitable for a wide range of water quality testing applications:

  • Drinking water (tap water, bottled water, drinking fountains)
  • Water for infants
  • Water purifiers
  • Underground water
  • Hydroponics
  • Laboratory use
Images showing various applications for the water quality tester
The LS310-2 can be used for multiple test scenarios, including water for infants, water purifiers, underground water, barrel-loaded water, drinking water in parks, and drinking fountains.

6. Maintenance and Precautions

  1. Avoid Corrosive Liquids: Do not use the device with corrosive liquids such as beverages, tea, or sewage.
  2. Clean Probe Before Calibration: To prevent contamination, ensure the instrument's probe is clean and free of water stains and dirt before calibration.
  3. Use Purified Water for Calibration: Always calibrate the instrument with purified water (e.g., bottled purified drinking water). Never use mineral or natural drinking water for calibration.
  4. Clean Residual Liquid: After measuring, clean any residual liquid from the probe to avoid mixing different liquids, which could lead to inaccurate test results.
  5. Temperature Range: Operate the device within the temperature range of 0-50°C. If used beyond this range, calibrate before use. Extreme temperatures can cause permanent damage.
  6. Cleaning Agents: Do not use alcohol or other organic solutions to clean the contact probe, as this can cause permanent damage.
  7. Initial Use/Inactivity: The instrument must be calibrated when used for the first time or after being inactive for a while.
  8. Battery Storage: Remove batteries if the instrument will not be used for a long period to prevent leakage and damage.

7. Troubleshooting

If calibration fails, consider the following possible reasons:

  • The instrument was not placed in pure water during calibration.
  • The probe is contaminated. Rinse it with clean water before attempting calibration again.
  • The light source may have attenuated, preventing normal operation. In this case, the device may need to be returned to the factory for inspection and maintenance.

8. User Tips

  • The LS310-2 uses standard AAA batteries, making replacements convenient and readily available.
  • This water quality tester is highly versatile and can be used for various applications, including drinking water, hydroponics, and laboratory testing.

9. Warranty & Support

  • Warranty: The gauge comes with a one-year warranty. For abnormal operation, please contact our company for maintenance.
  • Maintenance Services: We provide users with spare parts and lifelong maintenance services.
  • Calibration Service: We offer gauge calibration services.
  • Technical Support: Free technical support is available for the long term.

For further assistance, please refer to the official user manual PDF: User Manual (PDF)

10. Packing List

No.Product NameQuantityUnit
1Water Quality Meter1set
2AAA alkaline battery2pcs
3User Manual1pcs
Image showing the contents of the product packaging
Contents of the Digital TDS Meter packaging, including the tester, manual, and batteries.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.