Introduction
The ATTEN ST-1015 is an intelligent desktop AC ion fan designed to effectively eliminate static electricity from surfaces. It blows ionized air over electro-static sensitive products, making it ideal for industrial applications requiring dust removal and static elimination. The variable fan speed allows for precise control over the ionized airflow.
Product Overview
Components and Controls



- Angle adjustable knob: Allows adjustment of the fan's angle for optimal airflow direction.
- Power switch: Toggles the device on and off.
- Offset voltage adjust: Fine-tunes the ion balance.
- Indicator light: Provides visual feedback on the ionization status.
- Fan speed knob: Controls the speed of the fan, from minimum (MIN) to maximum (MAX).
- Power interface: Connects the device to the main power supply.
- Metal ground rod: Provides a grounding point for safety and optimal performance.
- Automatic cleaning device mask: Part of the self-cleaning mechanism.
- Ion launcher: Generates ions for static elimination. Replaceable.
- Double-roller DC Fan: Provides airflow.
- Dust-proof sponge & Dust-proof cover: Protect internal components from dust.
Product Video
Official product video demonstrating the features and components of the ATTEN ST-1015 Static Eliminator AC Ion Fan.
Setup
- Unpacking: Carefully remove the ST-1015 from its packaging and inspect for any damage. Retain packaging for future transport or storage.
- Placement: The device supports Desktop, Hanging, and Clamping installation methods. Choose a stable location within the effective range (400x1500mm) of the area requiring static elimination. Adjust the fan angle using the angle adjustable knobs on the sides for optimal coverage.
- Power Connection: Connect the power cable to the power interface on the rear of the device. Ensure the power source is AC 220-240V~ 50/60Hz.
- Grounding: For safety and optimal performance, connect a grounding wire to the metal ground rod located near the power interface.
Operating Instructions
- Power On: Flip the Power switch to the 'ON' position. The ionization indicator light should illuminate, indicating the device is active.
- Adjust Fan Speed: Rotate the Fan speed knob to set the desired airflow. Turn towards 'MIN' for lower speed and 'MAX' for higher speed.
- Adjust Offset Voltage: If necessary, use the Offset voltage adjust control to fine-tune the ion balance. This ensures optimal static neutralization for specific applications.
- Static Elimination: The ST-1015 will begin emitting ionized air to neutralize static charges. It is designed to eliminate static electricity from 1000V to 100V within 2 seconds.
Maintenance
- Automatic Cleaning: The device is equipped with an automatic cleaning device. While this reduces manual effort, periodic inspection is recommended.
- Ion Launcher Replacement: The ion launcher is a consumable component and may require replacement depending on usage frequency. Refer to the exploded view diagram in the Product Overview section for its location. Consult a qualified technician for replacement if needed.
- Dust Filter Cleaning: Regularly inspect and clean the dust-proof sponge and dust-proof cover to maintain optimal airflow and prevent dust accumulation on internal components.
Troubleshooting
No specific troubleshooting steps are detailed in the provided product information. If the ATTEN ST-1015 is not functioning as expected, please ensure the following:
- The power cable is securely connected to both the device and a working power outlet.
- The Power switch is in the 'ON' position.
- The ionization indicator light is illuminated.
- The fan speed knob is not set to 'MIN' if airflow is expected.
If issues persist, contact customer support for further assistance.
Specifications
| Feature | Specification |
|---|---|
| Model | ST-1015 |
| Voltage | AC 220-240V~ 50/60Hz |
| Power | 15W |
| Air flow | ≤2.4m³/min |
| Static Elimination Time | ≤2S |
| Ion Balance | ±10V |
| Ion Balance Adjustable | Yes |
| Ion Balance Alarm Value Range | ±15V ~ ±50V |
| Effective Range | 400*1500mm |
| Work conditions | Temperature: -5℃~45℃ Humidity: <85%RH |
| Dimensions | 146 (L) x85 (W) x238 (H) mm |
| Weight (Net) | ≈2.98Kg |
| Installation Method | Desktop, Hanging, Clamping |
User Tips
No specific user tips or common questions were available from the provided buyer reviews or Q&A content.
Warranty and Support
Product Guarantee
Products are thoroughly checked before packaging and shipment to ensure they match your order, quantity, and are in good condition.
Returns
You have 7 days from the date of receipt to contact the seller for returns. If the item is in your possession for more than 7 days, it may be considered used and might not be eligible for a refund or replacement. All returned items must be in their original packaging, and you must provide the shipping tracking number and a specific reason for the return.
Customer Support
If you experience any issues or have questions regarding your ATTEN ST-1015, please do not hesitate to contact the seller for assistance. Your satisfaction is a priority, and the seller is committed to resolving any problems.