DR55B01 DC 5-24V 2A Flip-Flop Latch Motor Reversible Controller User Manual

Model: DR55B01 | Brand: eletechsup

1. Introduction

The DR55B01 is a versatile self-locking (bistable) reverse polarity controller module designed for DC applications. It functions as a flip-flop latch relay, allowing for easy control of motor direction, LED polarity, or solenoid valve states with a simple low pulse trigger. This manual provides detailed instructions for its setup, operation, and maintenance to ensure optimal performance.

2. Specifications

ParameterValue
Input VoltageDC 5V (5V version); DC 6-24V (12V version)
Module Working CurrentForward: 2mA; Reverse: 35-40mA
Load VoltageEqual to input voltage
Load Current (Max)2A (Motor <=1A)
Control MethodLow pulse trigger (0.2-2 second)
Dimensions (L x W x H)43mm x 21mm x 16mm
Weight13.5 g
FeaturesSelf-locking (bistable), Power indicator, Reverse polarity indicator

3. Package Contents

Each package contains:

  • 4 x DR55B01 DC 5V-24V Self-locking (bistable) Reverse Polarity Controller Modules
Four DR55B01 modules in a package
Figure 1: Contents of the DR55B01 module package.

4. Setup

4.1 Pin Description

  • I+: Power Input +
  • I-: Power Input -
  • O+: Power Output + (When reversed, this becomes Power Output -)
  • O-: Power Output - (When reversed, this becomes Power Output +)
  • G: Trigger signal input ground
  • T: Trigger signal input terminal (requires a 0.2-2 second low pulse trigger)

4.2 Wiring Diagram

Refer to the diagram below for proper connection of the DR55B01 module to your power source, load (e.g., motor, LED, solenoid valve), and trigger mechanism (e.g., button, MCU IO).

Wiring diagram for DR55B01 module showing power, load, and trigger connections
Figure 2: DR55B01 Wiring Diagram and Usage Example.

4.3 Important Notes for Setup

  • For stable operation, ensure your power supply provides sufficient current. The power supply current should be greater than 2 times the load current.
  • The maximum load current for the module is 2A. If controlling a motor, the maximum load current is 1A.
  • This module is designed to control forward and reverse polarity only. Starting and stopping are controlled by powering the module on and off.
Top view of DR55B01 module showing LED indicators for power and reverse polarity
Figure 3: DR55B01 module with Power Indicator (PWR) and Reverse Polarity Indicator (DO).

5. Operation

The DR55B01 module operates as a bistable (self-locking) reverse polarity controller. Its state changes with each trigger pulse.

  1. Initial State (Power-on): Upon applying power, the output polarity will be the same as the input polarity (output = input).
  2. First Trigger: Press the trigger button (or send a low pulse to the 'T' terminal). The module will switch to reverse polarity output. This state will hold.
  3. Second Trigger: Press the trigger button again. The module will switch back to the original output polarity (output = input). This state will hold.
  4. Subsequent Triggers: Each subsequent trigger will alternate the output polarity between reverse and original.
  5. Stopping Output: To stop the output, turn off the power to the module.

6. Troubleshooting

  • Module not working stably or unexpectedly resetting:
    Ensure your power supply provides sufficient current. The power supply current should be at least twice the expected load current. Insufficient current can lead to erratic behavior.
  • Motor not operating or operating weakly:
    Check the load current. If controlling a motor, ensure its maximum current draw does not exceed 1A. For other loads, ensure it does not exceed 2A. Overloading can damage the module or prevent proper operation.
  • Output polarity does not change after triggering:
    Verify that the trigger signal is a low pulse lasting between 0.2 and 2 seconds. A pulse that is too short, too long, or not a low pulse may not be registered by the module. Check connections to the 'T' and 'G' terminals.
  • No power indicator light:
    Check the input voltage and polarity to the I+ and I- terminals. Ensure the voltage matches the module version (5V or 6-24V).

7. User Tips

  • Power Supply Sizing: Always use a power supply with a current rating significantly higher than your maximum expected load, especially when driving motors, to prevent instability or damage.
  • Trigger Button Quality: For reliable operation, use a good quality momentary push-button for manual triggering.
  • Motor Protection: When controlling inductive loads like motors, consider adding a flyback diode across the motor terminals to protect the relay from voltage spikes.

8. Maintenance

The DR55B01 module is designed for low maintenance. To ensure its longevity:

  • Keep the module clean and free from dust and debris.
  • Avoid exposing the module to extreme temperatures, high humidity, or corrosive environments.
  • Do not attempt to open or modify the module, as there are no user-serviceable parts inside.

9. Warranty and Support

For technical assistance, troubleshooting, or inquiries regarding product warranty, please contact the manufacturer, eletechsup, or your original point of purchase. Please retain your purchase receipt as proof of purchase for any warranty claims.