ANENG VD802

ANENG VD802 Non-contact AC Voltage Detector Tester Meter User Manual

Model: VD802

1. Product Overview

The ANENG VD802 is a pen-style non-contact AC voltage detector (NCV) designed for safe and efficient electrical testing. It provides a reliable method to detect AC voltage in circuits, outlets, and wires without direct contact, enhancing safety for users. Its features include intelligent zero/firewire recognition, breakpoint detection, adjustable sensitivity, and an integrated LED flashlight for use in low-light conditions.

ANENG VD802 Non-contact AC Voltage Detector
The ANENG VD802 Non-contact AC Voltage Detector.

2. Package Contents

Please check the package for the following items:

  • 1 x ANENG VD802 AC Voltage Tester
  • 1 x User Manual
ANENG VD802 Package Contents
Illustration of the VD802 packaging and included accessories.

3. Setup and Battery Installation

The ANENG VD802 requires 2 x 1.5V AAA batteries (not included) for operation.

  1. Locate the battery compartment cover, usually at the rear or bottom of the device.
  2. Open the battery compartment.
  3. Insert two 1.5V AAA batteries, ensuring correct polarity (+/-).
  4. Close the battery compartment cover securely.

Warning: Ensure the device is off before installing or replacing batteries. Do not mix old and new batteries, or different types of batteries.

4. Operating Instructions

4.1 Power On/Off

  • Press the power button (usually marked with a power symbol) to turn the device on.
  • The device will automatically shut down after 5 minutes of inactivity or if no AC voltage is detected, to conserve battery life.
Automatic Shutdown Feature
The automatic shutdown feature activates after 5 minutes of no operation.

4.2 Non-Contact AC Voltage Detection

The VD802 detects AC voltage in the range of 12V to 1000V AC (50/60Hz).

  1. Turn on the device.
  2. Bring the non-contact tip of the tester close to the wire, outlet, or circuit you wish to test.
  3. If AC voltage is detected, the tester will emit an audible alarm (beeping sound) and the LED indicator will flash. The frequency of the beeping and flashing may increase with stronger voltage signals.

4.3 Sensitivity Adjustment

The device features adjustable sensitivity for different testing scenarios.

  • Press the 'S' button to cycle through high, medium, and low sensitivity modes.
  • Adjust sensitivity as needed to avoid false positives or to detect voltage in less accessible areas.

4.4 Zero/Firewire Recognition

The VD802 can intelligently distinguish between live (fire) and neutral (zero) wires.

  • When testing an outlet or wire, the device will indicate a live wire with a fast flashing red light and a rapid hum.
  • For a neutral wire, the indicator will not be bright or will show a different, less intense signal.
Zero Firewire Recognition Diagram
Intelligent zero/firewire recognition: The zero line shows no bright light, while the line of fire shows a fast flashing red light and short hum.

4.5 Line Breakpoint Detection

This feature helps locate breaks in live wires.

  1. Move the tester along the length of a live wire.
  2. The device will indicate the presence of electricity with a red light flashing and a hum.
  3. When the tester passes a breakpoint, the alarm will stop or significantly change, indicating the interruption in the circuit.
Line Breakpoint Detection Diagram
Road along the fault detection, there are electric pencil red light flashing alarm frequency fast hum frequency slow for breakpoint location.

4.6 Zero Wire Insulation Testing

The VD802 can assist in safely determining the quality of zero wire insulation.

Zero Wire Insulation Testing Diagram
Safer easily determine the zero wire good quality assured with sound and light alarm.

4.7 Flashlight Function

The integrated LED flashlight can be activated for use in dark environments.

  • Press the flashlight button (usually marked with a light bulb symbol) to turn the flashlight on or off.

5. Maintenance and Care

  • Cleaning: Wipe the device with a dry, soft cloth. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Battery Replacement: If the device does not power on or the indicators are dim, replace the AAA batteries. Remove batteries if the device will not be used for an extended period to prevent leakage.
  • Transparent Cover: The device features a high-strength transparent cover designed to be scratch-resistant, not easy to break, and wear-resisting.
High Strength Transparent Cover
The VD802 features a high strength transparent cover for durability.

6. Troubleshooting

  • Device not turning on: Check if the batteries are correctly installed and have sufficient charge. Replace batteries if necessary.
  • Inconsistent readings: Ensure the tip is close enough to the conductor. Adjust sensitivity using the 'S' button. Ensure there are no strong electromagnetic fields nearby that could interfere with readings.
  • No alarm when voltage is present: Verify the device is powered on and batteries are good. Ensure the NCV tip is making proper proximity contact.

7. Specifications

ANENG VD802 Features and Specifications
Key features and dimensions of the ANENG VD802.
FeatureSpecification
ModelVD802 (also referred to as AC10)
AC Voltage Range12V ~ 1000V AC (50/60Hz)
Display TypeDigital Only
Operating Temperature0°C ~ 40°C
Power Supply2 x 1.5V AAA Batteries (Not Included)
Alarm ModeSound and Light
FlashlightYes
NCV SensitivityHigh, Medium, Low (Adjustable)
Automatic ShutdownAfter 5 minutes of no operation/no voltage detection
MaterialABS
DimensionsApprox. 157.3mm x 24mm (6.18in x 0.95in)
WeightApprox. 43g
Accuracy ClassClass III

8. User Tips

  • Always test the detector on a known live circuit before use to ensure it is functioning correctly.
  • When detecting breakpoints, move the tester slowly along the wire to pinpoint the exact location of the break.
  • Utilize the flashlight in dimly lit areas to improve visibility and safety during testing.
  • Adjusting the sensitivity can help in crowded electrical panels to isolate the specific wire you are testing.

9. Warranty and Support

For any issues, questions, or support regarding your ANENG VD802 Non-contact AC Voltage Detector, please contact the seller or manufacturer directly. Keep your purchase receipt for any warranty claims.


ANENG VD802 Non-Contact Voltage Tester Pen: How to Use & Features Demo

ANENG VD802 Non-Contact Voltage Tester Pen: How to Use & Features Demo

0:55 • 1280×720 • demonstration
ANENG VD802 Non-Contact AC Voltage Detector: Features and Demonstration

ANENG VD802 Non-Contact AC Voltage Detector: Features and Demonstration

1:10 • 1280×720 • demonstration

Related Documents - VD802

Preview ANENG B19 Digital Tester Pen User Manual
User manual for the ANENG B19 Digital Tester Pen, providing detailed instructions, safety guidelines, and technical specifications for electrical testing applications.
Preview ANENG VD802 Non-Contact Voltage Detector: User Manual & Specifications
Comprehensive user manual for the ANENG VD802 non-contact voltage detector. Features include AC voltage testing (12-1000V), adjustable sensitivity, LED torch, and safety guidelines. Get detailed operation instructions and technical specifications.
Preview ANENG B16 Digital Tester Pen User Manual - High Precision AC Voltage and NCV Detector
Comprehensive user manual for the ANENG B16 Digital Tester Pen. Learn how to use its high-precision AC voltage measurement and Non-Contact Voltage (NCV) detection features, understand its panel layout, operation instructions, and technical specifications.
Preview ANENG VD700 Digital Voltage Tester User Manual
User manual for the ANENG VD700 digital voltage tester, detailing its functions, features, and usage for detecting AC/DC voltage, live wires, neutral lines, breakpoints, and electrical fields.
Preview ANENG VC1010 Non-Contact Voltage Tester - Operation Instructions and Technical Specifications
Detailed operation instructions and technical specifications for the ANENG VC1010 non-contact voltage tester, including power on/off, torch function, AC voltage detection, auto power off, battery replacement, and detailed technical parameters.
Preview ANENG VC1010 Smart Induction Pen: AC Voltage Detector
Discover the ANENG VC1010 Smart Induction Pen, a contactless AC voltage detector offering high and low sensitivity switching, zero line recognition, non-contact measurement, flashlight lighting, and sound/light alarms. Learn about its features, specifications, and battery installation.