QUICK 861DW

Contents

QUICK 861DW SMD Rework Station

Instruction Manual

Model: 861DW | Brand: QUICK

1. Safety Instructions

CAUTION:

  • During the installation and use of this product, all electrical safety regulations of the country and regions must be strictly observed.
  • The power supply must be disconnected when disassembling the product. Do not operate with power on.
  • If the product does not work properly, please contact the supplier or our company, and do not disassemble or change the product in any way. We are not responsible for any problems caused by unauthorized maintenance or modification.

WARNING:

  • Do not install the product in a place where the surface is easy to shake or be impacted, as it may damage the product.
  • Do not place the product in places where it may be exposed to rain or moisture.
  • The product should be used away from places where there is magnetic interference.
  • Do not use in flammable and explosive environments.
  • Pay attention to the air outlet and its surroundings. High temperature operation, be careful of burns.
  • Power supply should be turned off during breaks or after work to avoid safety accidents.
  • Please keep the air outlet unblocked and ensure there is no obstruction.
  • Check and maintain the product regularly. Do not use the product when it is damaged, especially when the power cord is damaged.
  • The handle must be correctly placed on the holder, and do not replace it on the work surface. After completion, turn off the power switch when the machine automatically cools down to below 100°C (Enter Sleeping state).
  • Please unplug the power cord when the product is not used for a long time.

2. Overview

This product is suitable for desoldering and soldering of various components, such as SMD, SOP, SOG, etc. It can be used in many occasions, such as heat shrinkage, drying, paint removal, adhesive removal, thawing, preheating, disinfection, etc. Adjustable air volume, suitable for small air volume and large air volume heating occasions.

3. Product Characteristics

  • Three operating channels CH1, CH2 and CH3, each channel's parameters including temperature and air flow can be set.
  • Password protection and key locking.
  • Magnetic switch control, convenient and real-time operation.
  • Auto sleeping function, parameters can be set in sleeping mode.
  • Closed loop sensor, temperature can be controlled by zero voltage triggering mode and adjusted conveniently, accurate and stable, large power, rapid heating.
  • Brushless vortex fan, adjustable and wide range of air flow.
  • Automatic cooling system can prolong the lifetime of heater and protect the handle.

4. Product Specifications

QUICK 861DW Specifications
AttributeValue
Product Model861DW
Power Consumption1000W
Working VoltageAC 110V/220V
Temperature Range100°C ~ 500°C / 212°F ~ 932°F
Range of Air Volume1 ~ 120 Class
Airflow50L/min (Max)
Dimensions (L×W×H)189*265*141mm
WeightAbout 3.9Kg
CertificationCE
OriginMainland China
Image displaying product specifications including brand, product name, model, power, voltage, temperature range, air volume, product size, weight, and configuration.
Product Specifications Table

5. Functional Descriptions

5.1. Dimensions

Technical drawing showing the dimensions (Length, Width, Height) of the QUICK 861DW rework station in millimeters.
Dimensions of the QUICK 861DW Rework Station (Unit: mm)

5.2. Part Descriptions

Diagram labeling the main unit, holder, and handle of the QUICK 861DW rework station.
QUICK 861DW Rework Station with labeled components: 1. Main Master, 2. Bracket, 3. Handle, 4. Nozzle, 5. GND Wire, 6. Manual, 7. Dust Ball, 8. Anti-static Gloves.
NO.Part Descriptions
1Main unit
2Holder
3Handle

5.3. Key Descriptions

ButtonFunction Description
POWERPower switch
CH1Click it and work in the CH1 channel
CH2Click it and work in the CH2 channel
CH3Click it and work in the CH3 channel
TEMP▲/▼ (Left)Adjust the temperature
AIR▲/▼ (Right)Adjust the airflow
CH1&CH2Set the key tone function
CH1&CH3Temperature Calibration

5.4. Function Descriptions of Main Interface

Close-up of the QUICK 861DW display and control buttons for temperature, air, power, and channel selection.
Display showing temperature and air volume settings.
SymbolFunction
Heating state iconHeating state
((●))Display: Indicates that the key tone and alarm tone are on.
No display: Indicates that the key tone and alarm tone are off.
Real TempReal-time temperature

6. Setup

6.1. Initial Setup

  1. Place the desoldering station on a stable workbench.
  2. Connect the power supply to the product.
  3. Turn on the power switch.

6.2. Installing and Removing the Nozzle

Installation:

Insert the selected nozzle into the air outlet steel pipe of the handle, and then press the air nozzle into the air outlet steel pipe by hand, making sure that the air nozzle has been clamped before use.

Removal:

When disassembling the air nozzle, remove the handle from the air gun stand. There is a card slot between the air nozzle and the steel pipe of the air outlet. Put the handle on the air nozzle removal plate through the clamping groove, fix the air gun stand with one hand, and then gently pull the handle back to take out the nozzle.

Diagram illustrating the nozzle removal plate mechanism.
Nozzle Removal Plate Diagram. Replace the air nozzle after cooling down to avoid scalding.

7. Operating Instructions

In the initial state (the password is 000), the system is unlocked, and parameter settings and channel selection can be performed.

  1. Remove the handle from the holder; the system enters the normal working state. When the temperature is stable, the temperature window displays "Real Temp".
  2. If it is in the non-password locking state, the temperature and air volume parameters can be modified.
  3. After the work is completed, the handle of the air gun must be placed on the holder, at which time the desoldering station automatically enters the cooling stage. When the temperature cools to 100°C, it will enter the sleeping state and display "---".

7.1. Temperature Settings

Click the "TEMP▲" or "TEMP▼" key on the left. The temperature will rise or fall by 1°C. Long pressing the "TEMP▲" or "TEMP▼" key will make the temperature rise or fall rapidly.

7.2. Air Volume Settings

Click the "AIR▲" or "AIR▼" button on the right to increase or decrease the air volume by 1. Long pressing the "AIR▲" or "AIR▼" button will make the air volume increase or decrease rapidly.

7.3. Channel Settings

Click CH1, CH2, or CH3 to select channels 1 to 3. Long press the CH1 to CH3 buttons to store the airflow and temperature values of the current Channel.

Close-up of the CH1, CH2, CH3 buttons for setting and recalling three different working temperatures.
Three Temperature Lock Channels for one-click use.
Images showing the fast wind speed adjustment buttons and the LCD screen displaying temperature and wind speed.
Fast wind speed adjustment and LCD screen displaying temperature and wind speed.
Image demonstrating the magnetic switch control, where placing the handle on the stand activates sleep mode.
Magnetic Switch Control for convenient real-time operation and automatic sleep.

7.4. Operation Demonstration Video

Video demonstrating the basic operation of the QUICK 861DW, including power on, temperature and air volume adjustment, channel selection, and automatic sleep function.

8. Password Settings

In the initial state (the password is 000), the system is unlocked. To set a password:

  1. Turn off the power switch.
  2. Press and hold the "CH2" key while turning on the power switch. Do not release the "CH2" key until the window displays "C". After that, the window displays "password" and "SET", indicating the station is in password setting state.
  3. The hundreds digit will blink. Use the "TEMP▲" or "TEMP▼" keys to select the password value. Use the "AIR▲" or "AIR▼" keys to select the digits. Enter the digits in sequence, and press "CH2" to confirm.

Note:

  • Enter the password twice.
  • If the passwords entered for two consecutive times are inconsistent, the window displays "no", and the system enters the working state (password modification unsuccessful).
  • If the passwords entered for two consecutive times are the same, the window will display "SAV ___ " and give a prompt tone, indicating successful password change. The system will then enter the working state.
  • After the password is changed, you must enter the correct password to enter the password setting again.
  • If the password is not entered correctly, the window displays "no", and then directly enters the working state (keys are locked).
  • If the password is entered correctly, the window will display "SET" for about 20 seconds.
  • When the window displays "SET", press "CH2" to enter the new password setting.
  • If the window displays "SET", press "CH1" or "CH3" to exit the password setting and directly enter the working state (keys are locked).
  • If no operation is performed when the window displays "SET", the system will directly enter the working state (keys are locked).
  • After setting the password, turn on the power switch, and the window will display "no" and officially enter the working or sleep state.

9. Key Tone Settings

Press the "CH1" and "CH2" keys at the same time for about 2 seconds to switch the presence/absence of the key tone.

10. Sleeping Function

10.1. Enter Sleeping

  1. Put the handle on the handle holder, and the system will automatically enter the large air volume cooling state.
  2. When the display temperature drops to 100°C, the system will immediately enter the sleeping state, displaying "off" and then "Sleep".

10.2. Wake up Sleeping

When the handle is removed from the holder, the station immediately enters the working mode.

11. Temperature Calibration

The temperature should be recalibrated every time if the heating element is replaced.

  1. In the working state, set the calibration temperature to 300°C and 500°C respectively.
  2. When the temperature is stable, test the air outlet temperature with QUICK196 and record the reading value. Press the keys “CH1" and "CH3" at the same time for 5 seconds, and then the LCD will display "cal" for 2 seconds and the station will enter the temperature calibrating mode.
  3. Input the testing temperature after the hundreds digit blinks. Press "TEMP▲" or "TEMP▼" key to set the data and press “AIR▲" or "AIR▼" key to move the cursor. After inputting the testing result, click the "CH2" key for confirmation, and the temperature calibration is completed.
  4. If calibration is successful, the LCD respectively displays “C-L/C-H”; if it fails, the LCD displays “no”.
  5. In the working state, when the temperature is stable (300°C/450°C), use the tester to measure the temperature of the air outlet of the handle again. If there are still errors, repeat the calibration.

Note:

If there is no QUICK196, it is recommended that the temperature measuring head of the external sensor of the thermometer be placed 3~5mm away from the nozzle for temperature test.

12. Maintenance

12.1. Replacing the Heater

Note: All operating steps are performed with the power disconnected and the handle cooled.

Steps of removing the Heater:

  1. Unscrew the Anti-scald sheath at the front of the handle.
  2. Unscrew the three screws fixing the heater steel pipe.
  3. Pull out the damaged Heater assembly.
Diagram illustrating the components of the hot air gun handle: 1. Anti-scald sheath, 2. Screw, 3. Heater assembly, 4. Handle pencil body.
Heater components diagram.

Steps of replacing the Heater:

  1. Align the pins of the new Heater assembly with the socket of the Handle pencil body and insert it vertically.
  2. Reinstall the three screws that fix the steel pipe.
  3. Tighten the Anti-scald sheath.
  4. After the heater is replaced, please do the following measurements:
    Diagram showing the sensor and heater resistance values for 220V and 110V models.
    Sensor and Heater Resistance Values. Sensor resistance < 2Ω. Heater resistance: 220V: 40Ω (±10%), 110V: 10Ω (±10%).
  5. Calibrate the temperature, refer to soldering temperature calibration.

13. Troubleshooting

NO.Error displayError description
1H-EIndicates that there is a problem with the heater and the heater needs to be checked or replaced.
2S-EIndicates that there is a problem with the sensor and the sensor needs to be checked or replaced.
3ERRIndicates that the fan is faulty and needs to be checked or replaced.

14. User Tips

  • **Original Product:** This is an original QUICK product, ensuring quality and reliability.
  • **Weight Information:** The product itself weighs approximately 3.9kg. The total package weight is about 6.0kg.
  • **Nozzle Selection:** For optimal performance, especially with larger components, try to use a large-diameter nozzle.
  • **Safety First:** Always ensure the handle is placed on its holder when not in use to activate the automatic cooling and sleep functions, prolonging the heater's lifespan and preventing accidents.

15. Warranty and Support

The warranty period for this product is calculated from the date of purchase. During the warranty period, if the product breaks down under normal use, present the original warranty card to receive free service from an authorized repair company (or our company).

Warranty Exclusions (repairs will be charged):

  • Unable to offer a valid warranty card or certificate.
  • Purchase date, sales company, and other items are not completely filled, or the warranty card is altered.
  • Damage caused by failure to follow the use methods and precautions in the manual.
  • Damage caused by disassembly, repair, and modification of products without authorization of the manufacturer.
  • Replacement of vulnerable and consumable parts.

All items of the warranty card shall be completely filled in by the agent or user to obtain a 12-month warranty period. Please keep this warranty card properly; it will not be re-offered.

Contact Information:

QUICK INTELLIGENT EQUIPMENT CO., LTD.
ADD: NO.11, FengXiang Road, Wujin High-Tech Industrial Development Zone, Jiangsu, China
TEL: 86-519-86225678
FAX: 86-519-86558599
POSTCODE: 213167
WEBSITE: www.quick-global.com

A comprehensive user manual in PDF format is available for download here.

© 2023 QUICK. All rights reserved.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.