1. Introduction
Thank you for purchasing the SUGON 212 2-in-1 Soldering Station and Heat Gun. This device is designed for precision welding and maintenance tasks, combining a hot air rework station and a soldering iron into a single unit. It features dual digital displays, 6 memory channels, and a powerful 760W output for efficient and reliable performance.
This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your SUGON 212. Please read it thoroughly before use and keep it for future reference. For a comprehensive guide, you may also refer to the official user manual PDF available at SUGON 212 User Manual (PDF).
2. Safety Guidelines
Always observe the following safety precautions to prevent injury or damage to the device:
- Proper Use: Use this de-soldering station only for its specified purposes as described in this manual.
- High Temperatures: The air outlet and surrounding areas become extremely hot. Exercise caution to avoid burns.
- Handle Placement: When idle, always place the hot air gun handle correctly on its rack. Do not place it on the workbench or any other surface. Allow the station to cool below 100°C (entering sleep mode) before turning off the power switch.
- Airflow: Keep the air outlet unblocked. Clear any blockages immediately.
- Clearance: Maintain at least 2mm distance between the air outlet and the target item during use.
- Electrical Safety: This product uses a three-wire grounded plug. Ensure it is inserted into a three-hole grounded socket. Do not use the station if it is wet or if your hands are wet to prevent short circuits or electric shock.
- Flammable Materials: Do not use or store the station near flammable gases or combustible substances. When working in areas with combustible materials (walls, ceilings, floors), move the hot air handle back and forth to prevent ignition.
- Children: Keep the station out of reach of children. Electric products can be dangerous if misused.
- Damage: Regularly inspect and maintain the station. Do not use if damaged, especially if the power cable or air gun handle wire is compromised.
3. Product Overview
The SUGON 212 integrates a hot air rework station and a soldering station, offering versatile functionality for various electronic repair tasks.

Figure 3.1: SUGON 212 Soldering Station Component Diagram
This diagram illustrates the main components and controls of the SUGON 212, including the LED display screen, hot air gun, soldering iron, control buttons, and switches.
Key Components:
- LED Display Screen: Shows real-time temperature and air volume.
- Hot Air Gun: For rework tasks requiring hot air.
- Soldering Iron: For precise soldering.
- Heat Gun Memory Channel Buttons (CH1, CH2, CH3): Three programmable channels for hot air temperature and volume.
- Soldering Iron Memory Channel Buttons (CH1, CH2, CH3): Three programmable channels for soldering iron temperature.
- Temperature Adjustment Buttons (Up/Down): For setting desired temperatures.
- Air Volume Adjustment Buttons (Up/Down): For setting desired air volume.
- Heat Gun Switch: Powers the hot air gun.
- Soldering Iron Switch: Powers the soldering iron.
- Full Metal Bracket: Holds the hot air gun.
- Clean The Copper Wire Ball & Cleaning Sponge: For soldering iron tip maintenance.
- Welding Handle: The soldering iron handle.
4. Specifications
| Parameter | Value |
|---|---|
| Model Number | SUGON-212 |
| Maximum Power | 760W |
| Power Supply Voltage | AC 220V~50Hz / 110V~60Hz |
| Heat Gun Temperature Range | 100°C-500°C (212°F-932°F) |
| Soldering Iron Temperature Range | 200°C-450°C (392°F-842°F) |
| Pneumatic Method | Oil-containing motor |
| Maximum Air Volume | 100 L/min (Level 20-100) |
| Soldering Iron Power | 60W |
| Heat Gun Memory Channels | 3 |
| Soldering Iron Memory Channels | 3 |
| Certification | CE, FCC, WEEE |
| Weight | 2.7kg |
| Scope of Use | Computer and Mobile Phone Parts Repair |
Included Accessories:
- SUGON-212 Unit x1
- Air Gun Nozzles x4 (2x straight wind, 2x cyclone)
- Product Manual x1
- T12-I Soldering Tip x1
- T12-JL02 Soldering Tip x1
- T12-K Soldering Tip x1
- T12-BC2 Soldering Tip x1

Figure 3.2: SUGON 212 Soldering Station and Included Accessories
The main unit, hot air gun, soldering iron, and various tips and nozzles.
5. Setup
- Placement: Place the desoldering station on a flat, stable workbench.
- Nozzle Installation: Select the required air nozzle and install it onto the hot air gun. For general use, a larger diameter nozzle is often recommended.
- Handle Placement: Place the hot air gun handle securely in its designated holder.
- Power Connection: Connect the power cord to the station and then to a grounded power outlet.
- Power On: Flip the main power switch to the 'ON' position.
6. Operating Instructions
General Operation:
- Activate: Remove the hot air gun handle from its holder. The system will enter normal working mode, and the display will show the set and actual temperatures.
- Temperature & Air Volume Adjustment:
- Temperature Up/Down: Press the '▲' or '▼' button to adjust the temperature by 1°C. Hold the button for rapid adjustment.
- Air Volume Up/Down: Press the '▲' or '▼' button for air volume to adjust by 1 level. Hold the button for rapid adjustment.
- Memory Channels (CH1, CH2, CH3):
- Store Settings: After setting desired temperature and air volume, long-press the respective CH1, CH2, or CH3 button (for hot air or soldering iron) to save the current settings to that channel.
- Recall Settings: Short-press the respective CH1, CH2, or CH3 button to instantly recall the saved settings.
- Sleep Mode: When the hot air gun handle is returned to its holder, the station automatically enters a cold air cooling mode. Once the temperature drops below 100°C, it enters sleep mode.
- Power Off: For prolonged periods of non-use, turn off the main power switch and unplug the power cord.

Figure 3.3: Temperature Unit Conversion and Calibration Settings
Instructions for switching between Celsius and Fahrenheit, and entering temperature calibration mode.
Special Functions:
- Temperature Unit Conversion (℃/℉): In shutdown state, press and hold the hot air gun temperature '▲' button while turning on the power to switch between Celsius and Fahrenheit.
- Buzzer On/Off: In shutdown state, press and hold the hot air gun temperature '▼' button while turning on the power to toggle the buzzer sound.
- Temperature Calibration: When the host is turned off, press and hold the 'Multi-function key' for two seconds, then press the power switch to enter the temperature calibration setting interface. Press the air volume '+' key to set the corrected temperature, and click the 'More function key' to exit the temperature calibration function after the setting is completed.
- Sleep Temperature Setting: In shutdown state, press and hold the soldering iron '▲' button while turning on the power. Enter the soldering iron standby temperature setting page. Use the '▲'/'▼' buttons to set the standby temperature (0, 150, 180, 200°C). Setting to 0 turns off standby temperature. Settings are saved automatically after 3 seconds.
7. Maintenance
Soldering Iron Tip Maintenance:
- Temperature: Use the lowest possible temperature for soldering to prolong tip life. High temperatures can weaken the tip.
- Cleaning: Regularly clean the soldering iron tip with the cleaning sponge or copper wire ball. After welding, soldering flux can damage the tip if not cleaned.
- When Not in Use: Do not keep the soldering iron at high temperature for extended periods when not in use, as this can cause oxidation and damage.
- After Use: Clean the soldering iron tip and re-tin it with solder to prevent oxidation.
- Inspection: Set the temperature to 250°C (482°F). After stabilization, check and clean the tip. If black oxide is present, clean until removed. Replace the tip if it is deformed or heavily rusted. Do not use a knife to remove oxide.
Heat Gun Heating Element Replacement:
Replace the heating element only after it has cooled down and the power is disconnected.
- Loosen the anti-scald sleeve on the hot air gun handle and remove it.
- Unscrew the screws fixing the handle and open the handle.
- Unscrew the screws on the wiring board.
- Remove the old heating element and install the new one.
- Reassemble the handle in reverse order.

Figure 3.4: Heat Gun Heating Element Diagram
Illustration of the heat gun handle components, including the burning-proof cover, handle housing, heating element, and handle wire.
8. Troubleshooting
This section addresses common issues you might encounter with your SUGON 212. If the problem persists after following these steps, please contact customer support.
- No Power: Ensure the power cord is securely plugged into both the station and a working grounded outlet. Check the main power switch.
- Hot Air Gun Not Heating: Verify the heat gun switch is on. Check the temperature setting on the display. If the display shows "SLP" (sleep mode) or "---" (off), remove the handle from the holder or turn on the independent switch.
- Soldering Iron Not Heating: Verify the soldering iron switch is on. Check the temperature setting. If the display shows "SLP" or "---", ensure the iron is not in sleep mode or turned off.
- Inaccurate Temperature Readings: Perform a temperature calibration as described in the 'Special Functions' section (Section 6).
- Weak Airflow: Check for any blockages in the air outlet or nozzle. Ensure the air volume setting is appropriate.
- Tip Oxidation/Poor Soldering: Refer to the 'Soldering Iron Tip Maintenance' section (Section 7) for proper cleaning and re-tinning procedures. Replace the tip if severely damaged.
9. User Tips
- Voltage Compatibility: The station supports both AC 220V~50Hz and 110V~60Hz. Ensure you select the correct voltage model for your region. If your AC voltage is between 125V and 140V/60Hz, the 110V model should be compatible, but always verify with the manufacturer if you have concerns.
- T12 Handle Advantage: The SUGON 212 uses a T12 handle, which offers higher heating efficiency and a longer service life for the soldering iron tip compared to older 936 handles.
- Memory Channels for Efficiency: Utilize the three memory channels for both the hot air gun and soldering iron to quickly switch between frequently used temperature and air volume settings. This saves time and improves workflow.
- Dual-Mode Air Gun: Experiment with both direct wind and cyclone nozzles to find the best fit for different rework tasks. The dual-mode design provides flexibility for various applications.
- Application Scope: This station is ideal for repairing computer and mobile phone parts, as well as other delicate electronic components.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact the seller directly. Keep your purchase receipt as proof of purchase.