Introduction
The HTI Thermal Camera HT-A2+ is a versatile handheld thermal imager designed for a wide range of applications, including healthcare, public security, fire protection, archaeology, agriculture, and geology. It is an indispensable tool for electricians and maintenance technicians, enabling quick and efficient identification of problem areas through thermal imaging.
This device features a 256x192 infrared thermal image resolution and a broad temperature measurement range of -20℃ to 550℃. It offers adjustable emissivity, multiple color palettes, and various measurement modes to provide precise and detailed thermal analysis.
Product Overview
Familiarize yourself with the components of your HTI Thermal Camera HT-A2+:

- 3.2" Full Angle TFT Camera Screen: For displaying thermal and visible light images.
- Micro USB Port: For charging and data transfer.
- Navigation Button: Used for menu navigation (up, down, left, right).
- On/Off Button / Menu Button: Powers the device on/off and accesses the main menu.
- Save Button: To save captured images.
- Digital Camera Lens: For visible light imaging.
- Infrared Lens: For thermal imaging.
- Camera Lamp: Provides illumination for visible light images in low-light conditions.
- Selection/Entry Button: Confirms selections and enters menu options.
- Attachment Point: For securing a wrist strap or lanyard.
Setup
- Charging the Device: Before first use, fully charge the thermal camera using the provided USB cable and power adapter. Connect the Micro USB cable to the device and the adapter to a power outlet. The charging indicator will show the charging status.
- Powering On: Press and hold the On/Off Button / Menu Button for a few seconds until the screen illuminates.
- Language Selection: Upon initial power-on or after a factory reset, you may be prompted to select your preferred language. Use the Navigation Button to scroll through options (Chinese, English, German, Italian) and the Selection/Entry Button to confirm.
- Date and Time Setting: Set the correct date and time in the device settings for accurate timestamping of captured images.
Operating Instructions
Basic Operation
- Power On/Off: Press and hold the On/Off Button / Menu Button.
- Menu Navigation: Press the On/Off Button / Menu Button briefly to access the main menu. Use the Navigation Button (directional arrows) to move between menu items and the Selection/Entry Button to select an option.
- Capturing Images: Point the camera at the target. Once the desired thermal image is displayed, press the Save Button to capture and store the image.
Advanced Settings
The HT-A2+ allows for customization to suit various inspection needs:
- Color Palettes: The device offers five types of color palettes to visualize temperature differences. Access this setting via the menu. The available palettes are:
- Rainbow
- Iron Red
- Cool
- White Heat
- Black Heat

- Emissivity Adjustment: Emissivity (0.01~1.00 adjustable) is crucial for accurate temperature readings. Different materials have different emissivities. Adjust this value in the settings menu to match the surface being measured for optimal precision.
- Measurement Modes: The camera supports various measurement modes, including:
- Center Point: Displays the temperature at the center of the screen.
- Hot and Cold Spot Tracking: Automatically identifies and displays the maximum (MAX) and minimum (MIN) temperatures within the field of view.

- Image Display Modes: The HT-A2+ supports switching between different visual modes:
- Infrared: Displays only the thermal image.
- Visible Light: Displays only the image from the digital camera lens.
- Dual Light Fusion: Overlays the thermal image onto the visible light image, providing context and detail.

Video Demonstration
User Tips
- Resolution Clarification: The HT-A2+ model specifically features an infrared thermal image resolution of 256x192 pixels. While other models in the HTI series might have different resolutions (e.g., 320x240 or 220x160), for your HT-A2+, the 256x192 resolution is accurate and provides clear thermal imaging.
- Optimizing Emissivity: For the most accurate temperature readings, always try to adjust the emissivity setting to match the material you are inspecting. Common emissivity values for various materials can be found online or in specialized guides.
- Troubleshooting Applications: This thermal imager is highly effective for quick troubleshooting in various scenarios, such as identifying overheating components in electrical systems or pinpointing heat leaks in automotive engines. The dual light fusion mode can be particularly helpful for contextualizing thermal anomalies.
- Wider Field of View: The device offers a wide field angle of 56° × 42° and a focus length of 4mm, allowing for a clear image up to 100 meters, which is beneficial for inspecting larger areas or distant objects.

Maintenance
- Cleaning the Device: Use a soft, dry cloth to clean the exterior of the camera. For the lens and screen, use a lens cleaning cloth and a specialized cleaning solution if necessary, ensuring not to scratch the surfaces.
- Battery Care: The device uses a built-in 26649 rechargeable lithium battery. To prolong battery life, avoid fully discharging the battery frequently and store the device with a partial charge if not used for extended periods.
- Storage: Store the thermal camera in a cool, dry place within the specified storage temperature range of -20℃ to 60℃ (-4F to 140F). Ensure the relative humidity is below 80% RH.
- Avoid Extreme Conditions: Do not expose the device to extreme temperatures, direct sunlight for prolonged periods, or high humidity, as this can damage internal components.
Troubleshooting
If you encounter issues with your HTI Thermal Camera HT-A2+, refer to the following common problems and solutions:
- Device does not power on:
- Ensure the battery is sufficiently charged. Connect the device to the charger and wait for a few minutes before attempting to power on again.
- Press and hold the power button firmly for several seconds.
- Image is blurry or unclear:
- Clean the infrared and visible light lenses with a soft, lint-free cloth.
- Ensure you are within the optimal measurement distance for your target.
- Check the selected image display mode (infrared, visible light, or fusion) and adjust if needed.
- Temperature readings seem inaccurate:
- Verify that the emissivity setting is correctly adjusted for the material being measured.
- Ensure the ambient temperature is within the working temperature range of -10℃ to 50℃.
- Avoid measuring through reflective surfaces like polished metals without proper emissivity compensation.
- Device freezes or becomes unresponsive:
- Perform a soft reset by pressing and holding the power button until the device shuts down, then power it back on.
- If the issue persists, contact customer support.
- Cannot save images:
- Check if the internal storage is full. If so, transfer images to a computer and delete some from the device.
- Ensure the device is not in a mode that prevents saving (e.g., certain live view modes).
Specifications
| Feature | Specification |
|---|---|
| Model | HT-A2+ |
| Display Screen | 3.2-inch Full Angle TFT Display Screen |
| Detector Type | Vanadium Oxide Uncooled Infrared Focal Plane |
| Infrared Thermal Image Resolution | 256 × 192 |
| Visible Light Image Resolution | 640 × 480 |
| Lens Focal Length | 3.2mm |
| IFoV | 3.75mrad |
| Field Angle | 56° × 42° |
| Pixel Size | 12 μm |
| Image Frequency | ≤ 25Hz |
| Focusing Method | No focusing |
| NTED | ≤ 50mK @ 25℃, @ F/1.1 |
| Wavelength Range | 8~14 μm |
| Emissivity | 0.01~1.00 adjustable |
| Color Palettes | Rainbow/Iron Red/Cool/White Heat/Black Heat |
| Humidity Measurement Mode | Center Point/Hot and Cold Spot Tracking |
| Image Display Mode | Infrared/Visible Light/Dual Light Fusion |
| Temperature Measurement Precision | -15℃~550℃ ± 2℃ or ± 2%; -20℃~-15℃ ± 4℃ |
| Languages | Chinese, English, German, Italian |
| Automatic Shutdown Time | 5 minutes/20 minutes/No automatic shutdown |
| Battery Type | Built-in 26649 Rechargeable Lithium Battery |
| Image/Video Format | JPG/MP4 |
| Storage Temperature | -20℃~60℃ (-4F~140F) |
| Relative Humidity | < 80% RH |
| Working Temperature | -10℃~50℃ (14F~122F) |
| Temperature Range | -20℃~550℃ (-4F~1022F) |
| Product Size | 140 × 80 × 28 mm |
| Product Weight | 208g |
| Style | Handheld |
| Certification | CE, RoHS |
Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact the seller directly. Keep your proof of purchase for any warranty claims.