1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the HLTNC HY 4KW 5HP Variable Frequency Drive (VFD) Inverter Speed Controller. This VFD is designed for precise speed control of three-phase asynchronous motors, particularly suitable for high-speed rotation motors such as CNC spindle motors.
Key Features:
- RS485 communication port with standard international MODBUS main circuit control.
- Extremely strong anti-jamming capability.
- Low output rating torque (0.5Hz-150%), providing excellent low-speed running ability.
- Carrier frequency adjustable up to 16KHz for a soundless working environment.
- Broad voltage working area (304V-456V) ensuring normal operation.
- Automatic Voltage Regulation (AVR) technique to maintain inverter load capability.
- Various control techniques (synchronization and non-synchronization) for fast starting without changing brakes.
- Comprehensive error protection and short-circuit starting protection.
- PID control with advanced calculus PID closed-loop arithmetic for quick response and high suitability.
- Easy PLC function supporting 16 segments of speed and inverter control.
2. Safety Information
CAUTION:
- Do not open the cover when power is on or in inspection.
- Only well-trained personnel should install, operate, and maintain this equipment.
- Ensure all wires are properly grounded.
- Wait at least 10 minutes after power-off for discharge before touching internal components.
Always follow local electrical codes and safety regulations during installation and operation.
3. Specifications
| Attribute | Value |
|---|---|
| Output Current | 35A 18A 9A (Varies by model) |
| Output Frequency | 0-400 Hz |
| Model Number | HY04D011B, HY04D023B, HY04D043B |
| Output Power | 4KW |
| Type | DC/AC Inverters |
| Weight | 3KG |
| Size (LxWxH) | 21cm x 16cm x 21cm |
| Output Type | SINGLE |
| Origin | Mainland China |
| Certification | CE |
| Suitable Motor | <3.7KW (5HP) |
| Input Voltage | 220V 380V 1 or 3 phase |
| Output Voltage | 3 phase 220V 380V |
| Input Frequency | 47-63Hz |
Model Variations:
- HY04D011B: 110V Input
- HY04D023B: 220V Input
- HY04D043B: 380V Input

4. Product Overview and Components
The HLTNC VFD unit consists of a main control panel, terminal block for wiring, and a cooling system. The front panel provides controls for operation and programming, while the terminal block allows for connection to power input, motor output, and control signals.



5. Installation and Wiring
5.1 Main Circuit Terminal Description
Refer to the diagram below for the main circuit terminal connections. Ensure all connections are secure and correctly matched to your power supply and motor.

| Terminal Mark | Content Description |
|---|---|
| R, S, T | Power input terminal (220V class models, single and three-phase shared, single-phase optional two terminals access) |
| U, V, W | Inverter output to motor |
| P, PR | Brake resistor connection (optional) |
| P1P | DC reactor connector (remove the shorting link when using a DC reactor) |
| P, N | External Brake Assembly Connection |
| E | Ground terminal, according to electrical regulations (220V third ground, 380V special ground) |
5.2 Control Terminal Description
The control terminals allow for external control signals and monitoring. Refer to the table below for detailed functions.

| Terminal Mark | Content Description | Factory Setting |
|---|---|---|
| FOR | Multi-function input one | Forward rotation |
| REV | Multi-function input two | Reverse |
| RST | Multi-function input three | Reset |
| SPH | Multi-function input four | High speed |
| SPM | Multi-function input five | Medium speed |
| SPL | Multi-function input six | Low speed |
| DCM | Common terminal of digital control signal, +12V power supply (EV/IPV/P24) ground terminal | |
| EV(IPV) | +12V power supply | Maximum output current 200mA |
| P24 | +24V power supply | Maximum output current 200mA |
| +10 | Power supply for speed setting | +10V |
| VI | Analog voltage frequency command | 0~10V corresponds to the highest operating frequency |
| AI | Analog current frequency command | 4~20mA corresponds to the highest operating frequency |
| ACM | Common terminal of analog control signal | |
| DRV | Multi-function output terminal two (optical coupling) | DC24V/100mA |
| UPF | Multi-function output terminal one (optical coupling) | |
| FA (EFA) | Multi-function output terminal three (normally open/normally closed) | 3A/250V |
| FB (EFB) | Multi-function output terminal three (normally open/normally closed) | 3A/250V |
| FC (EFC) | Multi-function output terminal three (normally open/normally closed) | 3A/250V |
| KA (EKA) | Multi-function output terminal four (normally open) | 3A/250V |
| KB (EKB) | Multi-function output terminal four (normally open) | 3A/250V |
| AM | Digital frequency output terminal | 0-10V |
| RS+ RS- | RS485 communication port |
6. Operation
6.1 Control Panel Functions
The VFD features an intuitive control panel for easy operation and programming. The display shows various parameters and status indicators.

| Icon | Features | Explanation |
|---|---|---|
| ① | Power-on Run key | Power-on Self-test, display frequency. |
| ② | Programming key | Enter programming, exit programming. |
| ③ | Jog key | Jog key, can be used to display focus when setting parameters. |
| ④ | Up button | Up arrow key for parameter modification, page turning, and up. |
| ⑤ | Down button | Down arrow key for parameter modification, page turning, and down. |
| ⑥ | Data Function key | Enter the parameter value setting state and save the modified parameter value. |
| ⑦ | Forward and reverse switch | Switch between positive and negative during operation. |
| ⑧ | Speed control knob | Adjust the running speed. |
| ⑨ | Stop reset button | Stop running motor. |
| Indicator Light | State | Instruction |
|---|---|---|
| FOR | Bright | Indicates that the motor is in forward rotation |
| REV | Bright | Indicates that the motor is in reverse rotation |
| Hz | Bright | Display set frequency or output frequency |
| A | Bright | Display output current status |
| ROTT | Bright | Display motor speed status |
| HZ A | Bright | Display DC voltage |
| A ROTT | Bright | Display AC voltage |
| HZ ROTT | Bright | Display count value |
| HZ A ROTT | Bright | Display inverter temperature |
6.2 VFD Setting Instructions
The following video demonstrates the steps to configure the VFD settings, including restoring factory settings and adjusting frequency parameters.
Key settings demonstrated in the video:
| Parameter | Description |
|---|---|
| PD013=8 | Restore factory setting |
| PD005=400 | Set max operating frequency |
| PD004=400 | Set base frequency |
| PD002=1 | Set board potentiometer control |
| PD070=1 | Set analog input |
| PD072=400 | Set high analog frequency |
7. Maintenance
- Keep the VFD unit clean and free from dust and debris.
- Ensure proper ventilation around the unit. The internal fan runs continuously to maintain optimal temperature.
- Regularly check all wiring connections for tightness and signs of wear or damage.
- Avoid operating the VFD in environments with excessive moisture, corrosive gases, or extreme temperatures.
8. Troubleshooting
The HLTNC VFD is equipped with perfect error protection and short-circuit starting protection capabilities. In case of an error, the unit's display will show an error code. Refer to the full product manual (if available) for a comprehensive list of error codes and their solutions.
- No Power/Display Off: Check input power connections and ensure the power supply is within the specified voltage range.
- Motor Not Running: Verify motor wiring (U, V, W terminals), check VFD settings (e.g., frequency, control mode), and ensure the RUN command is active.
- Overload/Overcurrent: Check motor load, ensure motor parameters are correctly set in the VFD, and inspect for any mechanical issues with the motor or driven equipment.
- Overvoltage/Undervoltage: Verify input voltage stability.
If issues persist, contact technical support.
9. User Tips
- This VFD is specifically designed for three-phase asynchronous motors. It does not support external resistors unless customized.
- The VFD can accept either 1-phase or 3-phase 220V input. For 1-phase input, connect L1/L2 to any two of the VFD's R/S/T input terminals.
- The unit's output frequency is typically set to 400Hz by default. Adjust the parameters to match your motor's specific frequency requirements.
- This drive is highly effective for high-speed rotation motors, making it ideal for spindle motors in CNC engraving machines.
- The VFD utilizes Sine Wave PWM (SPWM) for its control system, ensuring smooth and efficient motor operation.
- If you encounter any problems, please contact customer support for assistance before attempting complex repairs or leaving feedback.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact details provided by your retailer or the manufacturer's official website. Keep your purchase receipt as proof of purchase.