NISSEI RS-402

Contents

NISSEI RS-402 Watt/SWR Meter User Manual

Model: RS-402

1. Introduction

The NISSEI RS-402 is a high-accuracy Watt and SWR meter designed for radio communication transceivers operating within the 125-525MHz frequency range. It allows for precise measurement of forward power, reflected power, and Standing Wave Ratio (SWR), with a maximum measurable power of up to 200 watts. This manual provides essential information for the proper setup, operation, and maintenance of your RS-402 meter.

2. Safety Information

  • Always ensure proper connections before applying power to prevent damage to the meter or connected equipment.
  • Do not exceed the maximum power rating of 200W.
  • Operate the device in a well-ventilated area to prevent overheating.
  • Keep the device away from moisture and extreme temperatures.
  • Use only the specified 13.8V DC power supply.

3. Package Contents

Please check the package for the following items:

  • 1 x NISSEI RS-402 Power Meter
  • 1 x Operation Manual (this document)
  • 1 x 13.8V DC Power Wire
NISSEI RS-402 Watt/SWR Meter with included manual and DC power cable
Figure 3.1: NISSEI RS-402 Watt/SWR Meter with included accessories.

4. Product Overview

The NISSEI RS-402 features a clear analog display for SWR and Power readings, along with intuitive controls for function selection and power range. The rear panel provides connection points for your transceiver, antenna, and DC power.

4.1 Front Panel Controls

Front view of NISSEI RS-402 Watt/SWR Meter showing controls and display
Figure 4.1: Front Panel of the RS-402 Meter.
  • S.W.R. & POWER Meter Display: Analog meter for reading SWR and Power.
  • FUNCTION Knob: Selects between FWD (Forward Power), REF (Reflected Power), and CAL (Calibration for SWR).
  • RANGE Knob: Selects the power measurement range: 5W, 20W, or 200W.
  • PEP Button: Press to measure Peak Envelope Power.
  • AVG/SSB Switch: Toggles between Average power measurement and SSB (Single Sideband) mode for PEP.
  • CAL Knob (MIN/MAX): Used for SWR calibration.

4.2 Rear Panel Connections

Rear view of NISSEI RS-402 Watt/SWR Meter showing TX, ANT, and DC 13.8V connectors
Figure 4.2: Rear Panel Connections.
  • TX Connector: Connects to your radio transceiver's antenna output. (M or N type)
  • ANT Connector: Connects to your antenna. (M or N type)
  • DC 13.8V Input: Power input for the meter.

5. Setup

Follow these steps to set up your NISSEI RS-402 Watt/SWR Meter:

  1. Power Connection: Connect the supplied 13.8V DC power wire to the 'DC 13.8V' input on the rear panel of the meter. Connect the other end to a stable 13.8V DC power source.
  2. Transceiver Connection: Connect the antenna output of your radio transceiver to the 'TX' connector on the rear panel of the RS-402 using a suitable coaxial cable.
  3. Antenna Connection: Connect your antenna to the 'ANT' connector on the rear panel of the RS-402 using a suitable coaxial cable.
  4. Initial Settings: Ensure the FUNCTION knob is set to 'FWD' and the RANGE knob is set to an appropriate power range (e.g., 200W) before transmitting.

6. Operating Instructions

6.1 Power Measurement (FWD/REF)

  1. Set the FUNCTION knob to 'FWD' to measure forward power.
  2. Select the appropriate power RANGE (5W, 20W, or 200W) based on your transceiver's output. Start with a higher range and decrease if the reading is too low.
  3. Transmit a continuous carrier (e.g., using FM or a tune function) at your desired power level.
  4. Read the forward power directly from the meter's 'POWER' scale.
  5. To measure reflected power, set the FUNCTION knob to 'REF' and repeat steps 3 and 4.

6.2 SWR Measurement

  1. Set the FUNCTION knob to 'FWD'.
  2. Select the appropriate power RANGE.
  3. Transmit a continuous carrier. Adjust your transceiver's power output to ensure the meter needle deflects sufficiently, ideally to the 'CAL' mark on the meter.
  4. While transmitting, rotate the CAL knob (MIN/MAX) until the meter needle aligns precisely with the 'CAL' mark on the SWR scale.
  5. Without changing the power output or CAL knob, switch the FUNCTION knob to 'CAL'.
  6. Read the SWR value directly from the 'S.W.R.' scale on the meter.
  7. After measurement, return the FUNCTION knob to 'FWD' or 'REF' for power monitoring, or turn off your transceiver.

6.3 PEP (Peak Envelope Power) Measurement

  1. Ensure the AVG/SSB switch is set to 'SSB'.
  2. Set the FUNCTION knob to 'FWD'.
  3. Select the appropriate power RANGE.
  4. Engage the PEP button.
  5. Transmit an SSB signal (e.g., by speaking into the microphone). The meter will display the peak power.

7. Specifications

FeatureSpecification
Frequency Range125-525MHz
Power Range1-200W
Power Scale5W / 20W / 200W
Maximum Power200W
Accuracy (5W range)(AVG) +/-10%; (REP) +/-15%
Accuracy (20-200W range)(AVG) +/-5%; (REP) +/-10%
Maximum Power for SWR Calibration3W (for accurate SWR calibration)
Input/Output ConnectorsM or N type
Net Weight800g
Insertion LossLess than 0.1dB
Testing FunctionsFWD/REF POWER, REP, SWR
Input/Output Impedance50 Ohm
Dimensions (W*H*D)190 x 85 x 135mm

8. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the exterior of the meter. Do not use abrasive cleaners or solvents.
  • Storage: Store the meter in a cool, dry place away from direct sunlight and extreme temperatures when not in use.
  • Connections: Periodically check all cable connections for tightness and signs of wear.

9. Troubleshooting

  • No Power Indication: Ensure the 13.8V DC power supply is connected correctly and providing power. Check the power cable for damage.
  • Incorrect Power Readings: Verify that the correct power RANGE is selected. Ensure all coaxial cable connections are secure. Confirm your transceiver is operating correctly.
  • SWR Cannot Be Calibrated: Ensure sufficient forward power is being transmitted (at least 3W for calibration). Check antenna and cable integrity.
  • Fluctuating Readings: This may indicate an unstable power source, loose connections, or issues with the transceiver or antenna.

10. User Tips

  • For the most accurate SWR readings, perform calibration at the lowest possible power setting that still provides a clear deflection to the CAL mark.
  • Always re-check SWR after making any changes to your antenna system (e.g., adjusting antenna length, changing cables).
  • When measuring PEP, ensure your voice or signal is consistent to get a stable peak reading.

11. Warranty and Support

For warranty information or technical support, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.