1. Product Overview

The Openlog Serial Data Logger is an open-source data recorder designed to log serial data to a Micro SD card. It functions similarly to a black box, capturing data from a main device via its UART serial port and saving it as text files. This module is particularly useful with flight control boards running Cleanflight firmware, enabling the recording of critical Unmanned Aerial Vehicle (UAV) operational data. The recorded data can be replayed and analyzed using Blackbox flight data recorder software.

Openlog Serial Data Logger module and Micro SD card slot
Figure 1: Openlog Serial Data Logger module with Micro SD card slot.

2. Specifications

FeatureDetail
Input Voltage3.3V ~ 12V (Recommended: 3.3V ~ 5V)
Memory Card SupportFAT32 format, up to 64GB Micro SD card
InterfaceUART Serial
Adjustable Baud Rates2400, 4800, 9600, 19200, 38400, 57600, 115200
Default BootloaderPro Mini ATmega328P 5V 16MHz
Operating ModesNew, Add, Command
IndicatorsTwo LED lights for running state
Idle Current2mA
Maximum Recording Current6mA
ApplicationComputer, Flight Control Boards (e.g., Naze32, F3)
TypeModule
Close-up of the ATmega328P chip on the Openlog module
Figure 2: Detailed view of the ATmega328P microcontroller on the Openlog module.

3. Setup Guide

  1. Prepare Micro SD Card: Ensure your Micro SD card is formatted to FAT32. The module supports cards up to 64GB.
    Micro SD card slot on the Openlog module
    Figure 3: Micro SD card slot for data storage.
  2. Insert Micro SD Card: Insert the prepared Micro SD card into the module's slot. Upon the first power-on with a new card, the module will automatically create a config.txt file on the card.
  3. Connect Power and Serial: The minimum connections required for operation are VCC (power supply), GND (ground), and RX (serial data receive).
    • VCC: Connect to a power source between 3.3V and 12V (3.3V-5V recommended).
    • GND: Connect to ground.
    • RX: Connect to the TX (transmit) pin of your main device (e.g., flight controller).
    • TX (Optional): Connect to the RX (receive) pin of your main device if two-way communication or command mode is desired.
    Openlog module with pin headers for connection
    Figure 4: Openlog module showing connection pins.
  4. Configure Baud Rate:
    • Open the config.txt file on the Micro SD card using a computer.
    • Modify the baud rate parameter within this file to match the baud rate of the serial port on your main device (e.g., flight control board). It is crucial that these baud rates are consistent for proper data logging.
    • Supported baud rates include 2400, 4800, 9600, 19200, 38400, 57600, and 115200.
  5. Integration with Flight Controllers: For use with Cleanflight firmware, connect the Openlog module to the appropriate serial port on your flight control board. Use the Cleanflight Configurator software on your host computer to enable and configure the Blackbox logging feature.

4. Operating Instructions

Once properly set up and connected, the Openlog Serial Data Logger will begin recording data transmitted over its UART serial interface to the inserted Micro SD card.

  • Data Logging: Data received via the RX pin will be saved as text files on the Micro SD card. The module supports three operating modes:
    • New Mode: Starts a new log file for each session.
    • Add Mode: Appends data to an existing log file.
    • Command Mode: Allows interaction with the module via a command-line interface for advanced control and configuration.
  • LED Indicators: Two LED lights on the module indicate its operational status. Refer to the module's specific firmware documentation for detailed LED behavior (e.g., blinking patterns for recording, errors, etc.).
  • Accessing Recorded Data: To access the logged data, safely remove the Micro SD card from the module and insert it into a computer. The data will be stored in text format.
  • Replaying Flight Records: For flight data recorded from UAVs, use specialized software like Blackbox flight data recorder software to replay and visualize the flight logs.

5. Maintenance

  • Micro SD Card Management: Regularly check the Micro SD card for available space. Back up important data periodically. If the card becomes full or corrupted, reformat it to FAT32.
  • Baud Rate Configuration: If you change the serial port baud rate on your main device, remember to update the config.txt file on the Micro SD card to match the new baud rate.
  • Firmware Updates: While not explicitly detailed, check the TENSTAR ROBOT or Openlog community resources for any available firmware updates that might improve performance or add features.
  • Physical Inspection: Periodically inspect the module for any signs of physical damage, loose connections, or corrosion.

6. Troubleshooting

  • No Data Recording:
    • Verify that the Micro SD card is correctly inserted and formatted to FAT32.
    • Check the config.txt file on the Micro SD card to ensure the baud rate matches that of the connected device.
    • Confirm that the VCC, GND, and RX connections are secure and correct.
    • Ensure the main device is actively sending data through its TX pin to the Openlog's RX pin.
    • Check the LED indicators for any error patterns.
  • Corrupted Data Files:
    • This can sometimes occur due to sudden power loss during recording. Always ensure stable power.
    • Try reformatting the Micro SD card and re-inserting it.
    • Ensure the Micro SD card is not faulty.
  • Module Not Powering On:
    • Check the input voltage to ensure it is within the 3.3V-12V range.
    • Verify VCC and GND connections.

7. User Tips

  • Firmware Compatibility: While designed for Cleanflight, always verify compatibility with other flight controller firmwares like Betaflight. Check community forums or the firmware's documentation for specific integration instructions.
  • Dedicated Micro SD Card: Use a dedicated, high-quality Micro SD card for logging to ensure reliability and prevent data loss.
  • Power Supply: For optimal performance and longevity, use a stable 3.3V to 5V power supply.

8. Warranty and Support

For warranty information, technical support, or further assistance, please contact the manufacturer, TENSTAR ROBOT, or your point of purchase. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.