1. Introduction
This manual provides essential information for the safe and efficient operation of your SUNSUN JP-450g water pump. This pump is specifically designed as an accessory for SUNSUN HW602B, HW603B, and HW604B external aquarium filters, ensuring optimal water circulation and filtration for your aquatic environment. Please read these instructions carefully before installation and use.
2. Safety Instructions
- Always disconnect the power supply before performing any maintenance, installation, or cleaning of the pump.
- Ensure the voltage and frequency of your power supply match the specifications of the pump (e.g., 220-240V/50Hz or 100-110V/60Hz).
- Do not operate the pump dry. Ensure it is fully submerged in water during operation to prevent damage.
- This pump is designed for indoor use in aquariums only. Do not use it for other purposes or in outdoor environments.
- Keep the power cord away from sharp objects and hot surfaces. Do not modify the power cord or plug.
- The maximum water temperature for operation is 35°C (95°F).
- If the pump or power cord is damaged, do not use it. Contact customer support for assistance.
3. Specifications
| Feature | Detail |
|---|---|
| Model | JP-450g (Original Water Pump Accessories for HW602B, HW603B, HW604B) |
| Input AC Voltage | 220-240V, 50Hz (Also available in 100-110V, 60Hz versions) |
| Power | 6W |
| Max Flow Rate | 400 L/H (Some variants may offer 800 L/H) |
| Max Head | 0.85m |
| Protection Rating | IPX8 |
| Max Water Temperature | 35°C |
| Suitable Hose Inner Diameter | 12mm |
| Material | Rubber |
| Fixed Form | Other (Designed for external filter attachment) |
| Battery Included | No |
| High-concerned chemical | None |
4. Package Contents
- 1 x SUNSUN JP-450g Water Pump
- Associated connection components (e.g., valve, as pictured)

5. Setup Instructions
- Unpack: Carefully remove all components from the packaging. Inspect for any damage.
- Connect to Filter: The JP-450g pump is designed to integrate with SUNSUN HW602B, HW603B, or HW604B external filters. Attach the pump to the designated inlet/outlet port of your filter bucket. Ensure a secure and watertight connection.
- Hose Connection: Connect the appropriate aquarium hose (with an inside diameter of 12mm) to the pump's outlet nozzle. Secure the hose with a clamp if necessary to prevent leaks.
- Placement: Ensure the pump is fully submerged in the aquarium water when connected to the filter. The filter unit itself should be placed according to its own instructions, typically below the aquarium water level.
- Power Connection: Once all connections are secure and the pump is submerged, connect the power plug to a suitable electrical outlet.

6. Operating Instructions
- Initial Start-up: After ensuring the pump is correctly installed and submerged, plug it into the power outlet. The pump should start circulating water immediately.
- Check Flow: Observe the water flow from the filter's outlet. Ensure there is a steady and consistent flow.
- Monitoring: Regularly monitor the pump's operation and the water flow. Any significant decrease in flow or unusual noises may indicate a problem.
- Shut Down: To turn off the pump, simply unplug it from the power outlet. Always unplug before handling the pump or performing maintenance.
7. Maintenance
Regular maintenance is crucial for the longevity and optimal performance of your water pump.
- Cleaning Impeller: Periodically, disconnect the power and remove the pump from the filter. Disassemble the pump housing (if applicable) to access the impeller. Clean the impeller and its chamber of any debris, algae, or mineral buildup using a soft brush and clean water.
- Hose and Connections: Check hoses and connections for blockages or leaks. Clean any buildup inside the hoses.
- Filter Media: Ensure the filter media in your external filter (HW602B/603B/604B) is clean and not impeding water flow, as this can strain the pump.
- Reassembly: After cleaning, reassemble the pump carefully, ensuring all parts are correctly seated and connections are tight.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump not starting | No power; Impeller jammed; Airlock | Check power connection; Clean impeller; Prime pump by ensuring it's fully submerged and free of air. |
| Reduced water flow | Clogged impeller/intake; Clogged filter media; Kinked hose | Clean pump and impeller; Clean/replace filter media; Straighten hose. |
| Unusual noise/vibration | Debris in impeller; Impeller worn or damaged; Pump not properly seated | Clean impeller; Inspect/replace impeller; Ensure pump is securely installed. |
| Water leaking | Loose connections; Damaged O-rings/seals | Tighten all connections; Inspect and replace O-rings/seals if necessary. |
9. User Tips
- For optimal performance, ensure your aquarium water level is consistently maintained above the pump's intake.
- Perform routine visual checks for any signs of wear or damage, especially to the power cord and connections.
- Consider keeping a spare impeller on hand, as this is often the first component to wear out in a water pump.
10. Warranty and Support
For any issues not covered in this manual, or for warranty claims, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase. A detailed user manual in PDF format may also be available from the seller for further reference.
11. Product Views