1. Introduction
This manual provides essential information for the safe and efficient operation of your SUMRY MPS-V MAX Series 10.2KW 48V On/Off Grid Solar Inverter. Please read this manual thoroughly before installation and use, and keep it for future reference. This inverter is designed to convert reliable, clean, and quiet AC energy for your on-grid, off-grid, or hybrid living, ensuring power supply even during outages.

2. Safety Instructions
Always observe the following safety precautions to reduce the risk of electric shock, fire, or injury:
- Ensure all wiring is performed by qualified personnel.
- Disconnect all power sources (PV, battery, AC input) before performing any maintenance or wiring.
- Do not disassemble the inverter. There are no user-serviceable parts inside.
- Install the inverter in a well-ventilated area, away from flammable materials and moisture.
- Ensure proper grounding of the inverter.
- Wear appropriate personal protective equipment (PPE) during installation and maintenance.
- The inverter provides comprehensive protections including Overload, Overheating, High/Low Voltage, Battery, Short Circuit, Overcurrent, Anti Reverse, and Power Failure protection.

3. Product Overview
3.1. Physical Description
The SUMRY MPS-V MAX Series inverter features a robust design suitable for various environments. It has a blue casing with a black base, an LCD display, and touch buttons for easy interaction.

3.2. Components and Ports
The inverter is equipped with various ports for AC input, AC output (main and second), PV inputs, and battery connections. It also includes dual communication ports for Battery Management System (BMS) and WiFi communication.

- AC input
- Main output
- Second output
- PV1 and PV2 input
- Battery input
- WiFi communication RS-232 Port
- Battery communication/RS-485 port

3.3. LCD Display and LED Indicators
The inverter features an LCD display and LED indicators to provide real-time status and operational information. Function buttons allow for navigation and setting adjustments.

| LED Indicator | Messages |
|---|---|
| INV/AC (Green) | Solid On: Output is powered by utility in Line mode. Flashing: Output is powered by battery or PV in battery mode. |
| CHG (Green) | Solid On: Battery is fully charged. Flashing: Battery is charging. |
| FAULT (Red) | Solid On: Fault occurs in the inverter. Flashing: Warning condition occurs in the inverter. |
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
4. Setup and Installation
4.1. Unboxing and Inspection
Upon receiving your inverter, carefully unbox it and inspect for any physical damage. Ensure all components listed in the packing list are present.
4.2. System Architecture
The inverter supports various configurations, including connections to solar panels, utility grid, generator, and battery banks to power home appliances.

4.3. Wiring Connections
Follow the wiring diagram carefully. Ensure all connections are secure and correctly polarized. The inverter features dual PV inputs and dual AC outputs for flexible system design.


PV Input: Connect your solar panels to the PV1+ / PV1- and PV2+ / PV2- terminals. The inverter supports a maximum PV input voltage of 500VDC and an MPPT voltage range of 90-450VDC per input. Solar panels are recommended to be connected in series.
AC Input/Output: Connect the AC input from the utility grid or generator to the AC IN terminals. Connect your loads to the MAIN OUT and SECOND OUT terminals. The nominal output voltage is 220/230/240VAC.
Battery Connection: Connect your 48V battery bank to the BATTERY +/- terminals. The inverter is compatible with various battery types including Flooded, Gel, Lithium-ion phosphate, Lithium-ion, AGM/Sealed, and user-customizable settings. It also features built-in Lithium battery automatic activation.

5. Operation
5.1. Initial Power-Up
After completing all wiring, ensure all connections are secure. Turn on the battery breaker first, then the PV breaker, and finally the AC input breaker. The inverter will initiate its startup sequence.
5.2. Basic Functions
The inverter operates as a pure sine wave device, ensuring stable and clean power for sensitive electronics. It can run without a battery, directly utilizing solar power or the grid.

The inverter can power a wide range of home and office appliances, providing backup power during outages.


5.3. Monitoring and Control
Monitor and control your inverter via the Smartess App, available for iOS and Android devices. The app provides real-time data and allows for remote management of your system.

6. Specifications
Detailed specifications for the SUMRY MPS-V MAX Series 10.2KW 48V On/Off Grid Solar Inverter are provided below:
| Category | Parameter | Value |
|---|---|---|
| PV INPUT (DC) | Nominal DC Voltage/Maximum DC Voltage | 360/500VDC |
| Start-up Voltage / Initial Feeding Voltage | 90VDC/120VDC | |
| MPPT Voltage range | 90-450VDC | |
| Maximum Input Current | 2/18A | |
| GRID OUTPUT (AC) | Nominal Output Voltage | 220/230/240VAC |
| Output Voltage Range | 195-253VAC | |
| Nominal Output Current | 35.6A / 44.3A | |
| AC INPUT | AC Start-up Voltage / Auto Restart Voltage | 120-140VAC/180VAC |
| Acceptable Input Voltage Range | 90-280VAC or 170-280VAC | |
| Maximum AC Input Current | 48.2A / 140A / 60A | |
| GENERAL | Dimension, D*W*H(mm) | 530*390*130 |
| Cartoon Dimension, D*W*H(mm) | 618*463*205 | |
| Net Weight (kgs) | 14.2 / 14.7 | |
| Gross Weight(kgs) | 15.7 / 16.2 | |
| INTERFACE | Communication Port | RS232/RS485/WIFI/GPRS/LITHIUM BATTERY |
| ENVIRONMENT | Humidity | 5% to 95% Relative Humidity(Non-condensing) |
| Operating Temperature | -10°C~50°C | |
| Compliance Safety | CE, FCC, RoHS |
Additional Specifications:
- Output Power: 1 - 200 KW
- Output Type: SINGLE
- Wave form: Pure sine wave
- Maximum PV Input power: 10200W
- Maximum charge current for solar: 160A
- Dual PV input: Yes
- Dual AC output: Yes (Main and Second)
- Is Smart Device: Yes (with WiFi/GPRS)
7. Troubleshooting
If you encounter issues with your inverter, refer to the LED indicator messages (Figure 6) for initial diagnosis. Common issues and their potential solutions are listed below:
- No Power Output: Check AC input, battery, and PV connections. Ensure all breakers are ON. Verify battery voltage is within operating range.
- Charging Issues: Check PV panel connections and voltage. Ensure the solar charge controller is functioning correctly. Verify battery type settings in the inverter.
- Overload Warning/Fault: Reduce the connected load. Ensure the total load does not exceed the inverter's rated output power.
- Overheating: Ensure the inverter is installed in a well-ventilated area. Clear any obstructions from the cooling vents.
- Communication Error: Check the RS232/RS485/WiFi/GPRS connections. Ensure the Smartess App is correctly configured.
For persistent issues, contact customer support.
8. User Tips
- MPPT Configuration: The inverter features dual independent MPPT inputs (PV1 and PV2). The MPPT voltage range of 90-450VDC applies to each individual PV input string. This allows for flexible solar panel array design and optimized power harvesting, especially when sunlight conditions vary across different panel groups.
- Output Voltage: The nominal AC output voltage for this model is 220/230/240VAC. Ensure your connected appliances are compatible with this voltage range.
- Load Capacity: With a 10.2KW rated power, this inverter can handle significant loads. For example, it can comfortably power multiple air conditioning units (e.g., two 750W units would only consume 1.5KW of the total capacity), along with other household or office appliances. Always calculate your total load to ensure it stays within the inverter's capacity.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact details provided by your seller or visit the official SUMRY website. Keep your purchase receipt as proof of purchase for warranty claims.