DykbRadio V7 RF power meter

Contents

RF Power Meter V7.0 User Manual

Model: V7 RF Power Meter

I. Instructions for Use

  1. Check if all accessories are complete after unboxing.
  2. Please refer to the advertisement description or wiring diagram for basic settings.
  3. Select the corresponding functional mode according to your requirements.

II. Product Overview and Setup

The RF Power Meter V7.0 is a high-performance, low-cost portable RF power meter designed for various applications including RF instrument calibration, equipment inspection, and signal detection. It features a 1.3-inch TFT LCD for offline operation and supports high-speed data communication via TYPE-C.

Package Contents

The standard package includes:

  • RF Power Meter V7.0 Host (with aluminum alloy housing) x 1
  • TYPE-C Cable x 1
  • N-type to SMA adapter x 1
  • 2.4G/5.8G Antenna x 1
  • Aviation plug to TTL adapter x 1 (Note: TTL serial port DATA cable needs to be purchased separately)
RF Power Meter V7.0 with included accessories: Type-C cable, N-type to SMA adapter, and a small antenna.

Figure 1: RF Power Meter V7.0 and included accessories.

Device Interfaces

The main unit features the following interfaces:

  • RF-IN: N-type male connector for RF signal input.
  • TYPE-C: USB port for 5V power supply and high-speed data communication.
  • TTL-UART: 4-pin aviation plug for TTL serial communication.
Side view of the RF Power Meter showing the N-type RF input connector.

Figure 2: N-type RF input connector.

Side view of the RF Power Meter showing the Type-C port for power and data, and the 4PIN aviation plug for TTL communication.

Figure 3: Type-C port and 4PIN aviation plug.

TTL Serial Port Pinout

The 4PIN aviation plug for TTL communication has the following pin assignments:

  • +5V: Power supply
  • GND: Ground
  • TXD: Transmit Data
  • RXD: Receive Data
Close-up of the 4PIN aviation plug on the RF Power Meter, showing pin assignments (+5V, GND, TXD, RXD).

Figure 4: 4PIN Aviation Plug Pinout.

Image of a TTL data cable (GX12 aviation plug - 4PIN) with VCC, RXD, GND, TXD wires, noting it needs to be purchased separately.

Figure 5: TTL Data Cable (purchased separately).

III. Operating Instructions

Power On/Off

  • Boot Process: Press the middle button and then long press the right arrow key.
  • Shutdown Process: Long press the middle button.

Display Information (TFT LCD)

The 1.3-inch TFT LCD displays the following information:

  • Freq: Frequency setting. This value is manually entered to calibrate the detection error at different frequencies. It does not represent the frequency measured by the power meter.
  • Power: Measured power value in Watts (W) and dBm. (0 dBm = 1 mW; 0 dBW = 10lg1W = 10lg1000mW = 30 dBm).
  • ATT: Numerical control attenuator value (0-31.75 dB). This value needs to be set when measuring signals larger than 0 dBm to improve accuracy.
  • Offset: Linear offset setting value used for:
    1. Setting offset when ATT is added.
    2. Calibration of interface errors.
    3. Setting relative error if an external amplifier or standard signal source is used.
  • Battery Indicator: Shows the internal lithium battery power (e.g., 95%).
  • IC Address: Displays the machine's internal address (e.g., IC000).
RF Power Meter V7.0 display showing frequency, power, attenuation, and offset.

Figure 6: RF Power Meter V7.0 Display.

Adjusting Settings

Use the arrow keys on the device to adjust parameters like frequency, attenuation, and offset. Pressing the up arrow increases the value, and the down arrow decreases it. After adjusting, press the confirm button to save the settings.

PC Software Operation

The RF Power Meter V7.0 comes with PC software for advanced control and data analysis. This software allows users to configure the power meter, record data, and share results. (Note: TFT LCD and TTL serial communication are not available when using the upper computer high-speed mode).

PC software interface displaying a 50kHz modulated signal, showing power (W, dBm), max/min values, markers, and data settings.

Figure 7: PC Software Interface with 50kHz Modulated Signal.

PC software interface displaying a flat signal, showing power (W, dBm), max/min values, markers, and data settings.

Figure 8: PC Software Interface with Flat Signal.

PC software interface displaying a 1kHz pulse modulated signal, showing power (W, dBm), max/min values, markers, and data settings.

Figure 9: PC Software Interface with 1kHz Pulse Modulated Signal.

Serial Communication (TTL-UART)

For serial communication, set the baud rate of your serial port assistant to 115200. All commands sent via the serial port assistant must include a carriage return.

Commands:

  • IC001+R: Query power.
  • IC001+T: Stop power transmission.
  • IC001+X: Query set values (ATT, FREQ, OFFSET).
  • IC001+L: Transmit power data at low speed (one data point every 0.5 seconds).
  • IC001+S: Transmit power data at high speed (one data point every 1 millisecond).
  • IC+SAVE+001+002: Change IC address (Old address before, new address after).
  • IC001+W ±02.2+01.25+1000: Modify data. Format is IC[Address]+W [OFFSET value]+[ATT value]+[FREQ value].

Example for Data Modification:

IC000+W-10.0+20.25+0800

This command sets the OFFSET offset value to -10.0dB, the internal numerical control attenuator (ATT) value to 20.25, and the frequency to 800MHz for the device with IC address 000.

Important Note on ATT Value: If the ATT value is not entered in 0.25 steps (e.g., 03.89), the device will only store the integer part (e.g., 03.00).

Video 1: Demonstration of RF Power Meter V7.0 signal measurement and PC software interaction.

IV. Maintenance

  • Do not use the product in damp or dusty environments.
  • Avoid severe impact or vibration on the product to prevent damage.

V. Troubleshooting

If you encounter any issues with the RF Power Meter V7.0, please refer to the operating instructions and specifications. Ensure all connections are secure and power supply is stable. For persistent problems, contact customer support.

VI. Specifications

FeatureSpecification
Measurement Power Range-60 to +30 dBm (0 to -40 dBm for good linearity)
Measurement Power Resolution±0.1 dBm
Measurement Frequency Range100KHz ~ 10GHz
Input Impedance50 Ω
Dynamic Range90dB
Working Voltage5VDC (powered by TYPE-C)
Charging Current300mA
Dimensions (L*W*H)66 * 36 * 24mm (excluding protruding N-head)
WeightLess than 100g
Housing MaterialFully CNC processed aluminum alloy
Display1.3 inch TFT LCD
BatteryBuilt-in Li battery
AttenuatorBuilt-in digital programmable attenuator (0-31.75dB)
RF Input InterfaceN-type male connector
Data/Power InterfaceTYPE-C USB
Serial Communication Interface4-port aviation plug (TTL-UART)

VII. User Tips

  • The device has been noted for its accuracy, with successful tests reported up to 3 GHz.
  • When using the PC software, remember that the on-device TFT LCD and TTL serial communication are not active in high-speed mode.
  • For precise measurements, especially with signals above 0 dBm, ensure the internal digital attenuator (ATT) is correctly set.

VIII. Safety Warnings

  • WARNING: Keep away from children and avoid misoperation.
  • WARNING: Do not disassemble or modify this product yourself. Non-professional repairs may cause damage or safety accidents.

IX. Warranty and Support

For any issues or support inquiries, please contact our store support. Refer to the product's official page for additional resources, including video demonstrations, drivers, host computer software, illustrative documents, and the TTL serial communication protocol. A download link for these resources is available: https://pan.baidu.com/s/1hki0Dsn4E5KCvss1YN1mrA (Extraction code: WYDZ).

An alternative download link is: http://115.28.16.44:81/file/Y4110.zip

X. Frequently Asked Questions (FAQ)

Q: What is the power resolution and accuracy? Is there a correction table for 1MHz-10GHz?

A: The measurement power resolution is ±0.1 dBm. The device's frequency setting is used to calibrate detection errors at different frequencies, not to directly measure the input signal's frequency. The device has a built-in digital programmable attenuator (0-31.75dB) and an offset function for calibration and error correction across its operating range of 100KHz to 10GHz.

Q: Does the device measure MHz?

A: The device measures RF power. The 'Freq' displayed on the screen is a setting for calibrating the power measurement based on the expected frequency of the signal, not a real-time frequency measurement of the input signal.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.