Schneider Electric LC1D Series

Contents

Schneider Electric LC1D Series Three-pole AC Contactor User Manual

Models: LC1D09, LC1D12, LC1D18, LC1D25, LC1D32, LC1D38

1. Introduction

The Schneider Electric LC1D series three-pole AC contactor is a protective device designed for reliable electrical control. It features a direct action structure with double breakpoints, ensuring efficient and safe operation. These contactors are characterized by their compact size, light weight, low power consumption, and long service life.

LC1D series contactors can be integrated to form mechanical reversible interlocking magnetic starters, star-delta decompression starters, and various other derivative series products. Additional auxiliary contact groups and air delay heads can be combined according to specific application requirements.

Key Features:

  • Product Type: AC Contactor
  • Number of Poles: 3P (Three-pole)
  • Auxiliary Contact: 1 Normally Open (NO) + 1 Normally Closed (NC)
  • Main Contact: 3 Normally Open (NO)
  • Control Circuit: AC 50/60Hz
  • Rated Voltage: Up to 440VAC (Main Circuit)
  • Coil Voltage Options: 24V, 110V, 220V, 380V AC
  • Rated Power: Up to 7.5KW (typical, varies by model)
  • Installation Method: Base plate or DIN rail mounting
  • Material: Silver alloy contacts, iron core, flame retardant shell, copper coil
  • Certification: CE
Schneider Electric LC1D Series AC Contactor
Figure 1.1: Schneider Electric LC1D Series AC Contactor

2. Safety Precautions

Read this manual carefully and follow all safety precautions before installing, operating, or servicing the AC Contactor. Ignoring these precautions may result in physical injury, death, or damage to the device.

2.1 General Safety Guidelines

  • Qualified Personnel: Only qualified electricians are permitted to install, operate, and maintain this contactor. Personnel must have professional electrical and safety training, be certified, and be familiar with all installation, commissioning, operation, and maintenance procedures.
  • Power Disconnection: Always ensure the input power supply is disconnected before performing any wiring, inspection, or component changes. Verify that the power is off and wait for any residual voltage to dissipate.
  • Unauthorized Modifications: Do not modify the contactor without authorization. Unauthorized alterations can lead to fire, electric shock, or other injuries.
  • Hot Surfaces: The base of the contactor's radiator may become hot during operation. Avoid touching it to prevent burns.
  • Electrostatic Discharge (ESD): Internal electrical parts and components are sensitive to electrostatic discharge. Take appropriate ESD precautions during any handling or servicing.
  • Installation Environment: Install the contactor on fire-retardant material and keep it away from combustible materials.
  • Damage Inspection: Do not operate the contactor if there is any visible damage or missing components.
  • Moisture: Avoid touching the contactor with wet hands or body, as this may cause electric shock.
  • Handling: Prevent physical shock or vibration during delivery and installation. Do not carry the contactor by its cover, as it may detach.
  • Accessibility: Install the contactor away from children and unauthorized personnel.
  • Grounding: Ensure proper grounding techniques are used, with a grounding resistance of less than 100 ohms. The PE grounding conductor should have the same cross-sectional area as the phase conductor.
  • Terminal Connections: R, S, and T are the input terminals for the power supply, while U, V, and W are the motor terminals. Connect input power cables and motor cables correctly to prevent damage to the contactor.

2.2 Warning Signs

SignNameInstruction
⚠DangerSerious physical injury or even death may occur if related requirements are not followed.
⚠WarningPhysical injury or damage to the devices may occur if related requirements are not followed.
ℹNotePhysical hurt may occur if related requirements are not followed.

3. Setup and Installation

Proper installation is crucial for the performance and longevity of the contactor. Ensure all local laws and regulations are followed.

3.1 Installation Environment

  • Temperature: Operate within -10℃ to +40℃. Avoid frequent temperature changes.
  • Humidity: Relative humidity should be ≤90%, non-condensing.
  • Altitude: For altitudes above 1000m, derating may be required. Consult technical specifications.
  • Vibration: Ensure vibration is ≤5.8m/s² (0.6g).
  • Atmosphere: Keep away from electromagnetic radiation, corrosive gases, oil mist, and flammable gases. Prevent foreign objects (metal powder, dust, oil, water) from entering the contactor. Do not install on flammable materials like wood.
  • Sunlight: Avoid direct sunlight.

3.2 Mechanical Installation

The contactor must be installed in an upright position to ensure adequate cooling. It can be mounted on a wall or within a cabinet.

Product size introduction for LC1D series contactors
Figure 3.1: Product Size Introduction for LC1D Series Contactors

Dimensions by Model:

ModelCurrent RatingWidth (mm)Depth (mm)Height (mm)
LC1D099A458477
LC1D1212A458477
LC1D1818A458477
LC1D2525A459085
LC1D3232A459085
LC1D3838A459085

3.3 Electrical Installation

All electrical work must be performed by a qualified electrician. Ensure the correct coil voltage is selected for your control circuit.

Contactor Wiring Diagram
Figure 3.2: Contactor Wiring Diagram (Example uses LC1D09, coil voltage 220V)

Wiring Steps:

  1. Grounding: Connect the ground wire of the input power cable to the ground terminal (PE) of the contactor.
  2. Main Circuit: Connect the 3-phase input power cable to terminals R, S, and T. Connect the 3-phase motor cable to terminals U, V, and W. Ensure all connections are tight.
  3. Control Circuit: Connect the control coil wiring to terminals A1 and A2. The coil voltage (e.g., 24V, 110V, 220V, 380V) must match your control circuit supply. Refer to the product label for the specific coil voltage of your unit.
  4. Auxiliary Contacts: Utilize the 1NO+1NC auxiliary contacts (typically labeled 13NO, 14NO, 21NC, 22NC) for control logic as needed.
  5. Secure Cables: Mechanically fasten all cables outside the contactor to prevent strain.
Coil Voltage Wiring Description
Figure 3.3: Coil Voltage Identification (Example shows 220V M7 coil)

3.4 Wiring Protection

  • Fuses: Select appropriate fuses as indicated in relevant electrical standards to protect the input power cable from short-circuits and thermal overload. Fuses also protect surrounding devices in case of an internal short-circuit within the contactor.
  • Motor and Motor Cables: The contactor provides inherent short-circuit protection for the motor and motor cables when sized correctly. No additional protection devices are typically needed for a single motor.
  • Multiple Motors: If the contactor is used with multiple motors, a separate thermal overload switch or circuit breaker must be used for protecting each cable and motor. These devices may require separate fuses for short-circuit protection.

4. Operation

The operation of the AC contactor is straightforward, primarily involving the energization and de-energization of its control coil.

4.1 Basic Operation

  1. Energizing the Coil: When the rated voltage is applied to the control coil (terminals A1 and A2), an electromagnetic field is generated. This field pulls the armature, causing the main contacts (3NO) to close.
  2. Main Contact Closure: With the main contacts closed, power is supplied from the input (R, S, T) to the load (U, V, W), allowing the motor or other electrical equipment to operate.
  3. Auxiliary Contact Operation: Simultaneously, the auxiliary contacts (1NO+1NC) change state. The Normally Open (NO) auxiliary contact closes, and the Normally Closed (NC) auxiliary contact opens. These contacts can be used for control circuit interlocking, signaling, or other auxiliary functions.
  4. De-energizing the Coil: When the voltage is removed from the control coil, the electromagnetic field collapses. A spring mechanism then returns the armature to its original position, causing the main contacts to open and the auxiliary contacts to revert to their normal state. This disconnects power from the load.

4.2 Coil Voltage

Ensure the control coil voltage matches the control circuit supply. Available coil voltages for the LC1D series include 24V, 110V, 220V, and 380V AC. The specific coil voltage is marked on the contactor's label.

5. Maintenance

Regular maintenance helps ensure the long-term reliability and safe operation of your AC contactor. All maintenance should be performed by qualified personnel with the power disconnected.

5.1 Maintenance Intervals

Perform the following checks periodically:

Checking PartChecking ItemMethodCriterion
Contactor BodyPhysical damage, cracks, discolorationVisual examinationNo damage or signs of overheating
Dust and dirtinessVisual examinationClean and free from obstructions
Terminals & WiringTightness of screwsTighten upSecure connections
Conductor insulationVisual examinationNo distortion or color-changing
ContactsWear, pitting, or carbon buildupVisual examinationMinimal wear, clean surfaces
Operating EnvironmentTemperature, humidity, foreign objectsVisual examination & instrument testConforming to specifications

5.2 Cleaning

Use a dry, lint-free cloth to clean the exterior of the contactor. For internal cleaning (only by qualified personnel), use compressed air to remove dust from contacts and moving parts. Do not use solvents or abrasive cleaners.

5.3 Power Cable Connections

Periodically check the tightness of all power cable connections. Loose connections can lead to overheating and potential failure.

6. Troubleshooting

This section provides guidance for common issues. For complex problems, contact technical support.

ProblemPossible CauseSolution
Contactor does not energize (main contacts do not close)
  • No control voltage to coil (A1-A2)
  • Incorrect coil voltage
  • Open circuit in control wiring
  • Damaged coil
  • Check control circuit power supply
  • Verify correct coil voltage for the contactor
  • Inspect control wiring for breaks or loose connections
  • Test coil continuity; replace contactor if coil is faulty
Contactor hums loudly
  • Low control voltage
  • Loose shading coil
  • Foreign object in magnet assembly
  • Misaligned armature
  • Verify control voltage is within specifications
  • Check for loose components; tighten if necessary
  • Inspect and remove any foreign objects
  • Replace contactor if armature is misaligned
Main contacts fail to close or open reliably
  • Worn or pitted contacts
  • Mechanical obstruction
  • Weak return spring
  • Overload condition
  • Inspect contacts for wear; replace contactor if severely worn
  • Check for and remove any obstructions
  • Replace contactor if spring is weak
  • Verify load current is within contactor rating
Contactor overheats
  • Excessive load current
  • Poor ventilation
  • Loose connections
  • Incorrect coil voltage
  • Check load current; ensure it does not exceed contactor rating
  • Improve ventilation around the contactor
  • Tighten all power connections
  • Verify correct coil voltage

7. Specifications

Below are the general specifications for the Schneider Electric LC1D series three-pole AC contactors. Specific values may vary by model.

7.1 General Specifications

  • Brand: Schneider Electric
  • Model Series: LC1D
  • Electricity Type: AC
  • Number of Poles: 3
  • Phase: 3
  • Main Circuit Rating Voltage: Up to 380V / 440V AC
  • Main Circuit Rating Current: 9A, 12A, 18A, 25A, 32A, 38A (depending on model)
  • Auxiliary Contacts: 1NO + 1NC
  • Control Circuit Frequency: 50/60 Hz
  • Coil Voltage Options: 24V, 110V, 220V, 380V AC
  • Certification: CE
  • Customization: Yes (is_customized)
  • Origin: Mainland China

7.2 Materials & Construction

  • Contacts: Silver alloy
  • Core: Iron core
  • Coil: Copper coil
  • Shell: High flame retardant material

7.3 Dimensions (Approximate)

ModelWidth (mm)Depth (mm)Height (mm)
LC1D09, LC1D12, LC1D18458477
LC1D25, LC1D32, LC1D38459085
Contactor Appearance Identification Diagram
Figure 7.1: Contactor Appearance Identification with Key Specifications

8. User Tips

  • Verify Coil Voltage: Always double-check the required coil voltage (e.g., 24V, 110V, 220V, 380V) for your specific application before purchasing and installation. This ensures compatibility with your control circuit and prevents damage.
  • Model Compatibility: If you are replacing an existing contactor or integrating into a specific system, ensure the LC1D model (e.g., LC1D09, LC1D12) and its current rating are appropriate for your load.
  • Accessories: For applications requiring specific interlocking functions or additional control, consider purchasing compatible auxiliary contact blocks or mechanical interlocks.
  • Ventilation: Ensure adequate ventilation around the contactor to prevent overheating, especially when installed in enclosed control panels or cabinets.

9. Warranty and Support

For product inquiries, technical assistance, or to report any issues, please contact the seller or manufacturer directly. Provide the model and serial number of your product for efficient support.

You can find additional manuals and product documents in PDF format online. Refer to the official user manual PDF for detailed technical specifications and advanced information: View User Manual (PDF)

© 2023 Schneider Electric. All rights reserved.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.