1. Introduction
Thank you for choosing the SEQURE T55 Preheating Rework Station. This intelligent hot plate is designed for precise heating and desoldering tasks, featuring a compact design and versatile power options. Please read this manual carefully before use to ensure correct operation and to prevent damage.
The T55 is equipped with a 128*32 OLED Display, supports multiple power supply modes, °C and °F temperature unit conversion, and a multi-language menu. It offers temperature compensation and intelligent temperature control with stability up to ±1%. Firmware upgrades are also supported.
2. Safety Precautions
- Use power supplies and accessories that meet safety standards. SEQURE accessories are recommended.
- Exercise extreme caution to avoid burns from the high-temperature heating plate when the device is in operation.
- When resting or after completing work, always turn off the power and store the heater in a location inaccessible to children.
3. Package Contents
Depending on the variant purchased, your package will contain the following:
T55 Host Only:
- T55 Host × 1
T55 (US/EU/UK/AU) Variants:
- T55 Host × 1
- PD 65W Power Supply × 1 (US/EU/UK/AU plug type, as selected)
- 100W 5A Fast Charging Line × 1
4. Setup
4.1 Component Structure
The T55 features an aluminum heating panel for quick and even heat distribution. An insulating layer with an aluminum radiator accelerates heat dissipation and reduces heat transfer to the control board. A slip-resistant silicone base ensures stability during operation.
4.2 Power Supply Connection
The T55 supports various power supply modes including PD, QC, and DC, with a maximum input of 25V. Ensure your power supply provides PD 20V ≥3A for optimal performance.
- Connect the Type-C cable to the T55's Type-C port.
- Connect the other end of the cable to a compatible power source such as a PD 65W fast charging head, PD mobile power bank, FPV Lipo Battery, or a standard power adapter.
5. Operation
5.1 Main Interface Overview
The 128*32 OLED display shows real-time information and allows for easy navigation. The main interface displays the hot plate temperature, working mode, power supply voltage, and any warning icons.
| Icon | Description | Method Of Operation |
|---|---|---|
| 200°C | Temperature of the Hot Plate | |
| High-V | High voltage warning | Please lower the supply voltage. |
| Low-V | Low voltage warning | Please increase the supply voltage or decrease the "LowVolt" setting value. |
| Pcb-T | PCB high temperature warning | Please disconnect the power supply, cool the soldering iron to room temperature, and then re-energize to work. |
| T1, T2, T3 | Operating temperature 1, 2, 3 | Short press A and B keys simultaneously to quickly switch between T1, T2, and T3. |
| 200°C (setting value) | Working temperature setting value | Short press A key or B key to set the working temperature value. |
| 00:00 | Heating Timekeeping | Set the switching function in the parameter of "Timing Display". |
| Power Output Percentage | Power progress bar | |
| Stop / Work | Stop mode / Working mode | Long press the A key to switch between working mode and stop mode. |
| 20.0V | Power supply voltage |
5.2 Menu Navigation
The T55 features a multi-language menu, including Chinese, English, and Russian.
5.2.1 Main Interface Operation Guide
- Long press the A key to switch between "Stop" mode and "Work" mode.
- Short press the A key or B key to adjust the working temperature setting value.
- Short press the A and B keys at the same time to quickly switch between the preset working temperatures T1, T2, and T3.
- Long press the B key to enter the First-degree menu.
5.2.2 Level 1 Menu Operation Guide
- Short press the A or B key to cyclically choose the functional block in the First-degree menu.
- Long press the A key or B key to enter the Level 2 menu.
- To return to the main interface, long press the A and B keys at the same time, or wait 5 seconds without any button operation.
5.2.3 Level 2 Menu Operation Guide
- Short press the A key or B key to loop through and select the Level 2 menu function box.
- Long press the A/B button to enter the secondary menu setting interface. A parameter setting box will appear.
- Short press the A/B button to set the parameter value.
- After setting, long press the A&B buttons simultaneously to exit the parameter setting box and return to the secondary menu. Alternatively, it will automatically exit and return to the secondary menu if no button is pressed for 5 seconds.
- To return to the Level 1 menu, long press the A and B keys at the same time, or wait 5 seconds without any button operation.
5.3 Menu Settings (Level 1 & 2)
| Level 1 Menu | English Secondary Menu | Description | Default Value | Setting Range |
|---|---|---|---|---|
| Temp | 1.Temp1 | Operating temperature 1 | 230°C | 50°C-280°C |
| 2.Temp2 | Operating temperature 2 | 250°C | 50°C-280°C | |
| 3.Temp3 | Operating temperature 3 | 270°C | 50°C-280°C | |
| 4.TempStep | The setting step value of the working temperature on the main interface | 10 | 1-50 | |
| 5.TempUnit | Temperature unit | °C | °C/°F | |
| Oled | 1.Brightness | Display brightness | 5 | 1-10 |
| 2.Language | Display language | EN | EN/中/Pycc. | |
| 3.TimeShow | Display heating timer | ON | OFF/ON | |
| 4.ScreenOpen | Standby screen display | ON | OFF/ON | |
| Other | 1.Buzzer | Buzzer | ON | OFF/ON |
| 2.HeatTime | Heating timer | 60m | OFF/1-60m | |
| 3.Power | Output power | 100% | AUTO/20-100% | |
| 4.LowVolt | Low voltage protection | OFF | OFF/10.0-23.0V | |
| 5.FactorySet | Restore the factory settings | OFF | OFF/ON | |
| About | "PD 20V ≥65W Input Max: 25V" | Information about power requirements | / | / |
6. Troubleshooting
When the hot plate displays a warning icon (and sounds the buzzer if enabled), follow the steps below to resolve the issue. The warning icon will automatically change to a "Stop" icon once the condition is eliminated.
- High-V (High voltage warning): Please lower the supply voltage.
- Low-V (Low voltage warning): Please increase the power supply voltage or decrease the "LowVolt" setting value in the menu.
- Pcb-T (PCB high temperature warning): Please turn off the power and allow the hot plate to cool down to room temperature. Then, turn on the power to resume work.
7. Specifications
| Parameter | Value |
|---|---|
| Model Name | T55 |
| Heating Area | 55*55mm |
| Working Temperature | 50°C-280°C / 122°F-536°F |
| Highest Voltage | 25V |
| Highest Power | 95W |
| Recommended Voltage | 19-25V |
| PD Power Supply | PD 20V ≥3A |
| Power Supply Mode | PD, QC, DC |
| Interface Type | Type-C |
| Screen Specification | 128*32 OLED |
| Size of Product | 55*60*37mm |
| Weight of Product | 92g |
7.1 Technical Reference: Heating Performance
| Working Voltage | Highest Current | Highest Power | Time of Heating up from 30°C to 200°C | Time of Heating up from 30°C to 280°C |
|---|---|---|---|---|
| 19V | 3.16A | 60W | 73s | 450s |
| 20V | 3.23A | 64W | 62s | 280s |
| 24V | 3.80A | 91W | 45s | 107s |
| 25.2V | 3.95A | 99W | 40s | 87s |
8. Firmware Update
To ensure you have the latest features and improvements, you can update the firmware of your T55 device.
- Visit the official SEQURE website: www.sequremall.com to download the newest firmware.
- Important: Pay close attention to downloading the firmware that specifically matches your product model. Using mismatched firmware can cause the product to work abnormally.
- Follow the instructions provided on the website for the firmware update process. Typically, this involves connecting the device to a computer via the Type-C port.
9. User Tips
- Power Brick Compatibility: If you encounter issues with certain PD power bricks, consider exploring alternative firmware options like 'Iron OS' if available and compatible, as some users report improved compatibility with a wider range of power delivery devices. Always verify compatibility and proceed with caution when using third-party firmware.
- Temperature Stability: The T55 boasts excellent temperature stability (±1%). For critical applications, allow the device a few minutes to stabilize after reaching the set temperature.
- Portability: Given its compact size and light weight (92g), the T55 is highly portable. Utilize mobile power banks for on-the-go repairs or field work.
10. Warranty & Support
10.1 Warranty Terms
- For performance faults caused by non-human factors within 3 months from the date of purchase, free repair and maintenance services are provided.
- After 3 months, no labor fee will be charged for repairs, but the cost of replacement parts must be covered by the user.
- The warranty does not cover man-made damage, faults caused by self-disassembly or improper use, and consumables such as soldering tips.
10.2 Contact Information
For further support or inquiries, please visit:
- Website: www.sequremall.com
- Email: info@sequremall.com
A comprehensive user manual in PDF format is also available for download: SEQURE T55 User Manual (PDF)