VariCore LTO 66160

Contents

Yinlong LTO 66160 Lithium Titanate Battery User Manual

Model: LTO 66160 | Brand: VariCore

1. Introduction

This manual provides essential information for the safe and effective use of your Yinlong LTO 66160 Lithium Titanate Battery. This 2.3V 45Ah cell is designed for high-power applications, offering exceptional cycle life and performance across a wide temperature range. It is suitable for building custom battery packs (e.g., 12V, 24V, 36V, 48V) for various energy storage and power needs.

Multiple Yinlong LTO 66160 batteries with busbars and nuts, highlighting 45Ah capacity, 2.3V, 25000 cycles, and -50°C to 65°C operating temperature.
Yinlong LTO 66160 Lithium Titanate Battery cells.

2. Safety Precautions

To ensure safe operation and prevent damage to the battery or personal injury, please observe the following precautions:

  • Do not collide or drop the battery.
  • Do not disassemble or squeeze the battery.
  • Prohibit battery polarity reversal or short circuit.
  • Prohibit batteries from being exposed to high temperatures or fires.
  • It is prohibited to immerse the battery in water or acidic, alkaline, or corrosive liquids.
  • Handle gently to avoid physical damage.
  • Ensure proper ventilation during charging and discharging.
Image detailing precautions and environmental icons like recycling, no littering, rainproof, handle gently.
Safety icons and precautions for battery handling.

3. Specifications

The following table details the technical specifications of the Yinlong LTO 66160 battery cell:

Parameter Value
Product NameLithium Titanate LTO Battery
Battery ModelLTO 66160
Battery BrandYinlong A-level
Nominal Voltage2.3V
Rated Capacity45Ah
Internal ResistanceLess than 0.4mΩ
Discharge Cut-off Voltage1.5V
Charging Cut-off Voltage2.9V
Maximum Continuous Discharge Current900A (20C)
Maximum Pulse Discharge Current900A (20C)
Cycle Life (80% DOD)25,000 cycles
Working Temperature-50°C ~ 65°C
Weight1.3 ± 0.05kg/pcs
Size (Diameter*Height)66*160mm
Transportation StandardUN 38.3 compliant

Note: Some specifications may vary slightly based on specific production batches or testing conditions. The height of the cell lugs is not included in the cell dimensions.

Detailed battery data table with specifications and dimensions, including nominal voltage, capacity, internal resistance, cycle life, and temperature range.
Detailed specifications from manufacturer data sheet.

4. Setup and Assembly

The battery cells are typically supplied with connectors (busbars) and M12 nuts for assembly into battery packs. Follow these general steps for setup:

  1. Inspection: Before assembly, visually inspect each cell for any signs of damage.
  2. Polarity: Identify the positive (+) and negative (-) terminals on each cell. The cells are clearly marked.
  3. Connection: Use the provided busbars and M12 nuts to connect cells in series or parallel to achieve the desired voltage and capacity for your battery pack (e.g., 4S for 12V, 8S for 24V, etc.). Ensure all connections are tight and secure to minimize resistance.
  4. BMS Integration: For multi-cell battery packs, a Battery Management System (BMS) is highly recommended to monitor cell voltage, balance cells, and provide overcharge/discharge protection. The BMS must keep the cell voltage within the cut-off voltage range (1.5V to 2.9V).
  5. Enclosure: Once assembled, place the battery pack in a suitable, well-ventilated enclosure to protect it from environmental factors and physical damage.
Image showing a single battery cell with included connectors and M12 nuts.
Battery cell with included connectors and M12 nuts for assembly.
Image displaying multiple battery cells arranged, demonstrating how they would be used in a pack.
Example arrangement of multiple battery cells.

5. Operating Instructions

The Yinlong LTO 66160 battery is designed for robust performance. Adhere to the following guidelines for optimal operation:

5.1. Charging

  • Charging Voltage: Do not exceed the charging cut-off voltage of 2.9V per cell.
  • Charging Current: The maximum continuous charge current is 400A. For optimal battery longevity, it is recommended to charge at a lower rate (e.g., 1C or 45A).
  • Temperature: Charge within the specified working temperature range of -50°C to +65°C.

5.2. Discharging

  • Discharge Voltage: Do not discharge below the cut-off voltage of 1.5V per cell.
  • Discharge Current: The maximum continuous discharge current is 900A (20C), and the maximum pulse discharge current is also 900A (20C).
  • Temperature: Discharge within the specified working temperature range of -50°C to +65°C.
Video demonstrating battery cells undergoing testing and charging processes in a factory environment.

6. Maintenance and Storage

  • Storage Temperature: The most suitable storage temperature is 25°C. Store in a cool, dry place away from direct sunlight and heat sources.
  • Long-Term Storage: For long-term storage, ensure cells are charged to approximately 50% of their capacity. Periodically check the voltage and recharge if necessary.
  • Cleaning: Keep the battery terminals clean and free from corrosion. Use a dry cloth to wipe the battery surface.
  • Environmental Protection: Dispose of batteries responsibly according to local regulations. Do not litter.

7. Troubleshooting

  • Low Voltage/No Power: Check individual cell voltages. If any cell is below 1.5V, it may be over-discharged. If using a BMS, check its status indicators.
  • Overheating: Discontinue use immediately if the battery becomes excessively hot. Check for short circuits, overcurrent conditions, or internal cell damage. Ensure adequate ventilation.
  • Reduced Capacity: Over time, capacity may naturally degrade. However, significant sudden drops could indicate cell imbalance or damage. Ensure proper charging and discharging practices.
  • Inconsistent Capacity: If building a pack, ensure all cells are balanced before initial assembly. If capacity discrepancies are noted after use, re-balance the cells using a suitable BMS or balancer.

8. User Tips

  • Verify Capacity: Upon receiving your cells, it is advisable to test each cell's actual capacity with a capacitance meter to ensure it matches the ordered specifications.
  • Cell Matching: For optimal performance and longevity in a battery pack, ensure that all cells used together are closely matched in terms of voltage and internal resistance.
  • BMS is Crucial: Always use a reliable Battery Management System (BMS) when assembling multi-cell packs to protect against overcharge, over-discharge, overcurrent, and to ensure cell balancing.

9. Frequently Asked Questions (FAQ)

Q: What is the actual capacity of these cells?
A: The nominal rated capacity is 45Ah. However, it is recommended to test individual cells upon receipt as some users have reported variations.
Q: Are these cells suitable for high-power applications?
A: Yes, with a maximum continuous discharge current of 900A (20C) and excellent low-temperature performance, these cells are well-suited for demanding high-power applications.
Q: Do I need a BMS for these batteries?
A: While individual cells can be used, a BMS is strongly recommended for any multi-cell battery pack to ensure safety, balance, and prolong the overall lifespan of the pack.

10. Warranty and Support

For any product-related inquiries, technical support, or warranty claims, please contact the seller or manufacturer directly. Refer to your purchase documentation for specific warranty terms and contact information.

A user manual in PDF format may also be available for download. Please check the product page or contact support for access to the User Manual (PDF).

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.