Introduction
Thank you for purchasing the mAT-S1500 SWR & Power Meter. This manual provides essential information for the safe and effective use of your device. The mAT-S1500 is a digital standing wave meter and power meter designed for HF shortwave radio stations, operating within the 1.8-54MHz frequency range.
For detailed technical specifications, manuals, or software specific to your model, please contact the seller.
Safety Warnings
Before using this product, please read and comply with all safety instructions.
Electrical Safety
- Use only the power adapter provided with the product or a compliant power supply.
- Do not use in humid environments unless the product specifically states a waterproof rating.
- If the power cord is damaged, discontinue use immediately and contact for replacement.
- Always disconnect the power before cleaning.
Usage Environment
- Operating temperature range: -10°C to 40°C (subject to model specifications).
- Avoid direct sunlight, high temperatures, and dusty environments.
- Ensure good ventilation and do not block heat dissipation holes.
Operational Safety
- Do not disassemble or modify the product yourself; there are no user-repairable parts inside.
- Prevent liquid from entering the product interior.
- If the product emits smoke, unusual odors, or abnormal noise, immediately disconnect the power and contact after-sales service.
Setup and Basic Operations
Unpacking Inspection
After opening the package, please check that all items are complete. If any items are missing or damaged, contact us immediately.
First Use
Ensure the product is fully charged before use (if applicable). Check if the power supply voltage is consistent with the product specifications (AC100-240V, 50/60Hz, applicable worldwide).
The device features built-in two high-capacity 18650 lithium batteries, providing approximately 8 hours of battery life.
Device Overview


Connections and Ports


- RF IN: Connects to the radio station.
- RF OUT: Connects to the antenna or a false load.
- CHARGE: Type-C charging port.
- DATA: DB9 data interface (not used yet).
- POWER: Power switch.
Basic Operations
- Power On/Off: Press and hold the power button for 3 seconds to turn the device on or off.
- Function Selection: Short press the mode button to switch functions.
- Display Screen: The 4.3-inch high-resolution LCD screen uses a dual display design for numbers and progress bars. It automatically sets the background color of the screen according to ambient light, offering both daytime and night modes.

Measurement Features
- Automatic Range Switching: The 3-speed power range (15W, 150W, 1500W) automatically switches according to the input RF signal strength. The range scale displayed on the screen will also change accordingly.
- High Precision Measurement: Designed with a radio frequency special measuring chip for good frequency consistency and accurate measurement of power and standing wave ratio.
- Peak and Instantaneous Power Display: The device can display both peak power (MAX PEP) and instantaneous power.
- High SWR Alarm: Progress bars show standing wave ratios in three colors: green (1.0-2.0), yellow (2.0-3.0), and red (3.0-10). If the measured SWR is higher than 3, the progress bar will turn red and an audible "Didi" alarm will sound.



Product Demonstration Video
Specifications

| Parameter | Value |
|---|---|
| Brand | MAT-TUNER (AISANRAY) |
| Model Number | mAT-S1500 |
| Type | Mini Amplifier (SWR & Power Meter) |
| Frequency Range | 1.8-54MHz |
| Power Measurement Range | 1-1500W |
| Power Accuracy | +/-5% (7MHz) |
| Interface | SO-239 (M mother) |
| Standing Wave Ratio Measurement Range | 1.00-9.99 |
| Standing Wave Ratio Accuracy | +/-3% (1.8-54MHz) |
| Impedance | 50Ω |
| Weight | 1.21kg |
| Origin | Mainland China |
| Input Power | AC100-240V, 50/60Hz or DC5V/9V/12V |
| Operating Temperature | -10°C ~ 40°C |
| Storage Temperature | -20°C ~ 60°C |
| Protection Level | IP20 (for indoor use, except for waterproof models) |
| Certification | NONE (Compliant with EU directives) |
| Built-in Battery | Yes (two high-capacity 18650 lithium batteries, approx. 8 hours life) |
| Recommended Headphone Maximum Impedance | < 32 Ohm (Note: This specification may be a generic category attribute and not directly applicable to this device's primary function.) |
| Output Type | LINE OUT (AUDIO OUT) (Note: This specification may be a generic category attribute and not directly applicable to this device's primary function.) |
| Input Type | LINE IN (AUDIO IN) (Note: This specification may be a generic category attribute and not directly applicable to this device's primary function.) |
Note: Specifications are subject to change without prior notice. Please refer to the product label for the most accurate information.
Maintenance and Care
- Cleaning: Wipe the outer casing with a soft, dry cloth. Do not use chemical solvents.
- Storage: When not in use for an extended period, clean and store in a cool, dry place.
- Battery (if applicable): If not used for an extended period, remove the battery to prevent leakage.
Troubleshooting Common Problems
| Problem | Possible Reasons | Solution |
|---|---|---|
| Unable to power on | Power not connected/battery depleted | Check the power connection, charge, and try again. |
| No display/Display error | Poor connection/Incorrect settings | Restart the device and check the connection. |
| Inaccurate measurement values (instrument-related) | Range error/calibration required | Confirm the measurement range and contact calibration services. |
| Other faults | - | Contact customer service for technical support. |
User Tips
- Charging Precaution: Do not measure while the device is charging, as this may damage the standing wave meter.
- Range Switching: The power range can only be switched from a lower setting to a higher setting during use. To switch to a lower power range, you must restart the standing wave meter.
- Frequency Range: The device is designed for 1.8-54MHz. If you require a wider frequency range (e.g., up to 500 MHz), please check for alternative models or contact the seller for specific product versions.
Warranty and Support
- Warranty Policy: 12/24 months from the date of purchase (subject to store announcement).
- Technical Support: For detailed technical documentation, calibration certificates, or hard copies of the manual, please contact us via AliExpress internal message or email: alisupport2026@163.com. Response time is typically within 24 working hours.
EU Compliance Information
CE Declaration of Conformity
This product complies with the essential requirements of the following EU directives:
- Low Voltage Directive (LVD) 2014/35/EU
- Electromagnetic Compatibility Directive (EMC) 2014/30/EU
- RoHS Directive 2011/65/EU
Waste Electrical and Electronic Equipment (WEEE)
The wheeled bin symbol marked with an X on the product indicates that, according to EU Directive 2012/19/EU, this product must not be disposed of as unsorted municipal waste and must be collected and recycled separately.
Disclaimer
This instruction manual is a general version; the actual product functions and parameters shall prevail. The manufacturer reserves the right to change product designs and specifications without prior notice.