1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of the FATEK FBs Series Programmable Logic Controllers (PLCs). The FBs Series offers cutting-edge technology, compact design, powerful performance, and an extensive product range, ensuring reliability and durability for various industrial automation applications.
The FBs Series PLCs are designed for electrical DIY supplies and are certified with CE and FCC standards, originating from Mainland China.
Figure 1: FATEK FBs Series Programmable Logic Controller
Video 1: FATEK FBs Series Product Overview
2. Safety Information
Always observe the following safety precautions when installing, operating, or maintaining the FBs Series PLC:
- Ensure power is disconnected before performing any wiring or maintenance.
- Only qualified personnel should install and service this equipment.
- Verify correct voltage and current ratings before connecting power.
- Avoid exposing the PLC to excessive moisture, dust, or corrosive gases.
- Ground the PLC properly to prevent electrical shock and ensure stable operation.
- Do not disassemble or modify the PLC unit.
3. Setup and Installation
3.1. Physical Installation
- Mount the PLC securely on a DIN rail or panel using appropriate fasteners.
- Ensure adequate ventilation around the unit to prevent overheating.
- Maintain sufficient clearance from heat sources and strong electromagnetic fields.
3.2. Wiring
The FBs Series PLCs feature 7.62mm fixed or detachable terminal blocks for wiring, depending on the specific model (MA/MB/MC units). Refer to the detailed wiring diagrams for your specific model.
- Power Supply: Connect the AC power (AC100-240V) to the L and N terminals. Ensure proper grounding.
- Digital Inputs: Connect input devices (e.g., sensors, switches) to the X terminals.
- Digital Outputs: Connect output devices (e.g., relays, indicators) to the Y terminals.
- Communication Ports: Connect communication cables to the built-in Port0 (USB or RS232) or expandable ports (Port1~4 for RS485, RS232, Ethernet, GSM, or ZigBee) as required.
Figure 2: FBs Series PLC with terminal block details
Figure 3: FBs Main Unit System Diagram with DIO, AIO, Temperature, Load Cell, Potential Meter, and Voice Modules
4. Operating Instructions
4.1. Powering On
Once all wiring is complete and verified, apply power to the PLC. The 'POWER' indicator LED should illuminate.
4.2. Status Indicators
- POWER: Indicates the PLC is receiving power.
- RUN: Indicates the PLC is executing the loaded program.
- ERR: Indicates an error condition. Refer to the troubleshooting section for details.
- TX/RX: Indicates data transmission/reception activity on communication ports.
4.3. Programming
The FBs Series PLCs are programmed using dedicated software. Connect your computer to the PLC via the USB or RS232 port (Port0) and use the FATEK programming environment to develop and download your control logic.
5. Maintenance
- Keep the PLC clean and free from dust and debris. Use a soft, dry cloth for cleaning.
- Regularly check all wiring connections for tightness and signs of corrosion.
- Ensure the operating environment remains within the specified temperature and humidity ranges.
- Periodically back up your PLC programs to prevent data loss.
6. Troubleshooting
- PLC not powering on: Check power supply connections, input voltage, and fuses.
- ERR indicator is on: This indicates a system error. Consult the PLC programming software for specific error codes and diagnostic messages. Common causes include program errors, hardware faults, or communication issues.
- Outputs not activating: Verify input conditions, check program logic, and inspect output wiring and external devices.
- Communication failure: Check cable connections, communication settings (baud rate, parity, data bits), and ensure the correct communication port is selected in the software.
7. Specifications
The FATEK FBs Series offers a wide range of models with varying specifications. Below are detailed specifications for different main unit types.
7.1. NC Positioning Main Units (MN)
| Specification | Model | FBS-20MNR | FBS-20MNT/J | FBS-32MNR | FBS-32MNT/J | FBS-44MNR | FBS-44MNT/J |
|---|---|---|---|---|---|---|---|
| Digital Input | 5VDC Differential (Ultra high speed 920KHz) | 2 points (1 axis) | - | 4 points (2 axes) | - | 8 points (4 axes) | - |
| 24VDC High speed (200KHz) | 4 points | - | 6 points | - | 8 points | - | |
| 24VDC Medium speed (Total 5KHz) | 6 points | - | 8 points | - | 12 points | - | |
| 24VDC Low speed | - | - | - | - | - | - | |
| Digital Output | Relay | 6 points | - | 8 points | - | 8 points | - |
| 5VDC Differential (Ultra high speed 920KHz) | 2 points (1 axis) | - | 4 points (2 axes) | - | 8 points (4 axes) | - | |
| Transistor High speed (200KHz) | - | 6 points | - | 4 points | - | 4 points | |
| Transistor Low speed | - | - | - | - | - | 8 points | |
| Communication Port | Built-in | 1 Port (Port0, USB or RS232) | |||||
| Expandable | 4 ports (Port1~4, RS485 or RS232 or Ethernet or GSM or ZigBee) | ||||||
| Calendar | Built-in | ||||||
| Built-in power supply | SPW24-AC/D12/D24 | ||||||
| Wiring mechanism | 7.62mm detachable terminal block | ||||||
| Dimension | Figure 1 | ||||||
7.2. Basic Main Units (MA)
| Specification | Model | FBs-10MAR | FBs-10MAT/J | FBs-14MAR | FBs-14MAT/J | FBs-20MAR | FBs-20MAT/J | FBs-24MAR | FBs-24MAT/J |
|---|---|---|---|---|---|---|---|---|---|
| Digital Input (24VDC) | High speed (100KHz) | 2 points | 2 points | 2 points | 2 points | 2 points | 2 points | 2 points | 2 points |
| Medium speed (20KHz) | 2 points | 2 points | 2 points | 2 points | 2 points | 2 points | 2 points | 2 points | |
| Medium speed (Total 5KHz) | 4 points | 4 points | 4 points | 4 points | 6 points | 6 points | 6 points | 6 points | |
| Digital Output | Relay | 4 points | - | 6 points | - | 8 points | - | 10 points | - |
| Transistor High speed (100KHz) | - | 2 points | - | 2 points | - | 4 points | - | 6 points | |
| Transistor Medium speed (20KHz) | - | 2 points | - | 4 points | - | 6 points | - | 6 points | |
| Communication Port | Built-in | 1 port (Port0, USB or RS232) | |||||||
| Expandable | 2 ports (Port1~2, RS485 or RS232 or Ethernet) | ||||||||
| Calendar | Built-in | ||||||||
| Built-in power supply | SPW14-AC/D12/D24 | SPW24-AC/D12/D24 | |||||||
| Wiring mechanism | 7.62mm fixed terminal block | ||||||||
| Dimension | Figure 2 | Figure 1 | |||||||
7.3. Basic Main Units (MA/MB)
| Specification | Model | FBs-32MAR | FBs-32MBR | FBs-32MAT/J | FBs-32MBT/J | FBs-40MAR | FBs-40MBR | FBs-40MAT/J | FBs-40MBT/J | FBs-60MAR | FBs-60MBR | FBs-60MAT/J | FBs-60MBT/J |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Digital Input (24VDC) | High speed (100KHz) | 2 points | |||||||||||
| Medium speed (20KHz) | - | 6 points | |||||||||||
| Medium speed (Total 5KHz) | - | 8 points | |||||||||||
| Medium low speed | 4 points | - | |||||||||||
| Digital Output | Relay | 12 points | - | 16 points | - | 24 points | - | ||||||
| Transistor High speed (100KHz) | - | 6 points | - | 6 points | - | 6 points | |||||||
| Transistor Low speed | - | 4 points | - | 8 points | - | 16 points | |||||||
| Communication Port | Built-in | 1 port (Port0, USB or RS232) | |||||||||||
| Expandable | 2 ports (Port1~2, RS485 or RS232 or Ethernet) | ||||||||||||
| Calendar | Built-in | ||||||||||||
| Built-in power supply | SPW24-AC/D12/D24 | ||||||||||||
| Wiring mechanism | 7.62mm fixed terminal block (MA), 7.62mm detachable terminal block (MB) | ||||||||||||
| Dimension | Figure 1 | ||||||||||||
7.4. Advanced Main Units (MC)
| Specification | Model | FBs-10MCR | FBs-10MCT/J | FBs-14MCR | FBs-14MCT/J | FBs-20MCR | FBs-20MCT/J | FBs-24MCR | FBs-24MCT/J | FBs-32MCR | FBs-32MCT/J | FBs-40MCR | FBs-40MCT/J | FBs-60MCR | FBs-60MCT/J | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Digital Input (24VDC) | High speed (200KHz) | 2 points | 6 points | ||||||||||||||
| Medium speed (20KHz) | 2 points | 2 points | |||||||||||||||
| Medium low speed (0.47ms) | - | 6 points | 4 points | 8 points | 20 points | ||||||||||||
| Digital Output | Relay | 4 points | - | 6 points | - | 8 points | - | 10 points | - | 12 points | - | 16 points | - | 24 points | - | ||
| Transistor High speed (200KHz) | - | 2 points | - | 2 points | - | 4 points | - | 4 points | - | 6 points | - | 6 points | - | 8 points | |||
| Transistor Medium speed (20KHz) | - | 2 points | - | 4 points | - | 4 points | - | 2 points | - | - | - | ||||||
| Communication Port | Built-in | 1 port (Port0, USB or RS232) | |||||||||||||||
| Expandable | 4 ports (Port1~4, RS485 or RS232 or Ethernet or GSM or ZigBee) | ||||||||||||||||
| Calendar | Built-in | ||||||||||||||||
| Built-in power supply | SPW14-AC/D12/D24 | SPW24-AC/D12/D24 | |||||||||||||||
| Wiring mechanism | 7.62mm fixed terminal block | 7.62mm detachable terminal block | |||||||||||||||
| Dimension | Figure 2 | Figure 1 | |||||||||||||||
8. User Tips
- Programming Software: For programming the FATEK FBs Series PLC, you will need specific programming software. Ensure you have the correct version compatible with your PLC model.
9. Warranty and Support
FATEK is a brand you can rely on, known for its reliable and durable products since 1992.
- Returns: Free returns are available within 90 days.
- Delivery Guarantee: Fast delivery is ensured. In case of delays, a coupon code may be provided. Refunds are issued if the package is lost or items are damaged, or if no delivery occurs within 30 days.
- Security & Privacy: Your personal details are protected and not shared with third parties without consent. Payments are secure.
For further assistance, please contact your local FATEK distributor or the HMI-PLC Store where the product was purchased.