Geevorks 9953W

Geevorks 9953W 5-in-1 Bluetooth WiFi Digital Water Quality Tester

User Instruction Manual

1. Introduction

The Geevorks 9953W is a versatile 5-in-1 digital water quality tester designed for continuous online monitoring. This instrument accurately measures pH, Electrical Conductivity (EC), Salinity (SALT), Specific Gravity (S.G), and Temperature. It is ideal for various applications including drinking water analysis, aquariums, hydroponic systems, swimming pools, and laboratory use. Featuring Bluetooth and WiFi connectivity, the device allows for convenient remote monitoring and data management via a dedicated smartphone application.

Geevorks 9953W 5-in-1 Water Quality Tester overview

Figure 1: Overview of the Geevorks 5-in-1 Water Quality Tester models, highlighting WiFi, APP, and Multiparameter features.

2. Features

  • 5-in-1 Multifunction: Measures pH, EC, SALT, S.G, and Temperature.
  • Wireless Connectivity: Supports Bluetooth and WiFi for remote monitoring and control via a smartphone app.
  • Digital Display: Clear digital screen with backlight for enhanced readability.
  • Alarm Function: Set custom alarm values within the app for specific parameters.
  • Data Storage: Automatic data storage for up to 30 days accessible through the app.
  • High Accuracy: Provides easy, accurate, fast, and steady measurements across wide ranges.
  • Versatile Applications: Suitable for drinking water, aquariums, hydroponics, swimming pools, ponds, and laboratory testing.
  • Compact Design: Space-saving unit with two suction cups for easy installation.
  • Temperature Units: Switchable between Celsius (℃) and Fahrenheit (℉).

3. Package Contents

Ensure all items are present in the package:

  • 1 x Water Quality Analyzer (Main Unit)
  • 1 x Electrode (Probe)
  • 1 Pack x Accessories (e.g., suction cups, mounting hardware)
  • 1 x Charger (US / EU / UK plug, depending on selection)
  • 1 x User Manual (English)
Package contents of the Geevorks 9953W tester

Figure 2: Contents included in the product package.

4. Specifications

Geevorks 9953W Technical Specifications
Parameter Value
Model Number 9953W
Display Type DIGITAL with Backlight
pH Range 0.00 - 14.00 pH
EC Range 0 - 19900 µs/cm, 0 - 199.0 ms/cm
SALT Range 0 - 199.0 ppt
S.G Range 0.990 - 1.400
Temperature Range 0℃ - 50℃ (32℉ - 122℉)
pH Resolution 0.01 pH
SALT Resolution 1 ppm (<1999ppm), 10 ppm (>1999ppm), 0.1 ppt
EC Resolution 1 µs/cm (<1999µs/cm), 10 µs/cm (>1999µs/cm), 0.1 ms/cm
S.G Resolution 0.001
Temperature Resolution 0.1℃ (0.2℉)
pH Accuracy ±0.03
SALT/EC Accuracy ±2% F.S
Temperature Accuracy ±1.0℃
Material ABS
Item Size 100 x 75 x 22 mm (3.94 x 2.95 x 0.87 inches)
Item Weight 121 g (4.27 oz)
Geevorks 9953W dimensions and specifications table

Figure 3: Device dimensions and detailed specifications.

5. Setup

  1. Unpack: Carefully remove all components from the packaging.
  2. Connect Electrode: Attach the electrode (probe) to the main unit. Ensure a secure connection.
  3. Power Connection: Connect the charger to the main unit and plug it into an appropriate power outlet (US/EU/UK plug depending on your model).
  4. Mounting: Use the provided suction cups to install the main unit and probes in your desired location, such as on the side of an aquarium or hydroponic reservoir. Ensure the probes are fully submerged in the water to be tested.
  5. App Installation: Download the compatible smartphone application (available for iOS and Android) from your device's app store.
  6. Initial Calibration: Refer to the in-app instructions or the included user manual for initial calibration steps to ensure accurate readings.
Geevorks 9953W main unit and probes

Figure 4: Main unit with connected probes.

Geevorks 9953W probes and suction cup mounting

Figure 5: Close-up of the probes and the suction cups for mounting.

6. Operating Instructions

6.1. Basic Operation

  1. Power On: Press the power button on the main unit to turn on the device. The digital display will illuminate.
  2. View Readings: The display will show real-time readings for pH, EC/SALT/S.G, and Temperature.
  3. Switch Mode: Use the 'MODE' button to cycle through different parameter displays if applicable.
  4. Temperature Unit: Use the 'TEMP/CAL' button to switch between Celsius (℃) and Fahrenheit (℉) temperature units.

6.2. App Connectivity and Remote Monitoring

  1. Pairing: Open the installed app on your smartphone. Follow the in-app instructions to pair your device via Bluetooth or connect to your WiFi network.
  2. Real-time Data: Once connected, the app will display real-time data from the tester.
  3. Alarm Settings: Within the app, you can set high and low alarm thresholds for parameters like pH, EC, and SALT. The app will send notifications if readings fall outside these ranges.
  4. Historical Data: The app automatically stores data for up to 30 days, allowing you to review trends and historical measurements.
Geevorks 9953W in aquarium with remote monitoring via app

Figure 6: Remote monitoring of water parameters in an aquarium using the smartphone app.

Geevorks 9953W app interface showing pH, salt, EC values and alarm settings

Figure 7: Screenshot of the mobile application interface with various parameter readings and alarm settings.

6.3. Data Export

The device supports exporting data to an Excel sheet for further analysis.

  1. Access Export Function: In the app, locate the 'Export' or 'Share' function.
  2. Select Data Range: Choose the desired time range for data export (e.g., hourly, daily, weekly, monthly).
  3. Enter Email: Provide your email address where the Excel sheet will be sent.
  4. Download: Download the Excel sheet from your mailbox after receiving the email.
Geevorks 9953W data export process from app to email

Figure 8: Steps for exporting data from the app to an Excel sheet via email.

7. Maintenance

  • Electrode Cleaning: Regularly clean the electrode with distilled water. Gently wipe it dry before storage or after each use to prevent residue buildup and ensure accurate readings.
  • Storage: Store the device in a cool, dry place when not in use. Ensure the electrode is properly capped or stored in a suitable solution as recommended by the manufacturer (if applicable).
  • Battery/Power: Keep the device charged using the provided charger. Avoid exposing the device to extreme temperatures.

8. Troubleshooting

This section addresses common issues you might encounter with your Geevorks 9953W water quality tester.

  • Inaccurate Readings:
    • Ensure the electrode is clean and free from debris.
    • Perform a calibration as per the instructions in the full user manual or app.
    • Check if the probes are fully submerged in the water sample.
  • Device Not Powering On:
    • Verify that the charger is properly connected and the power outlet is functional.
    • Ensure the device has sufficient charge.
  • App Connectivity Issues:
    • Ensure Bluetooth is enabled on your smartphone and the device is within range.
    • Check your WiFi connection and ensure the device is connected to the same network.
    • Restart both the device and the app.
  • No Data Export:
    • Verify the email address entered in the app is correct.
    • Check your spam or junk folder for the email.
    • Ensure a stable internet connection for data transfer.

9. User Tips

  • Power Adapter Compatibility: The device comes with various plug options (US/EU/UK). Ensure you are using the correct voltage adapter (e.g., 110V or 220V) compatible with your region to prevent damage.
  • Water Resistance: While designed for water testing, the main unit itself may not be fully waterproof (e.g., IP65 rated). Avoid submerging the main unit; only the probes are designed for immersion.
  • Regular Calibration: For the most accurate and reliable readings, especially for pH, perform regular calibrations as recommended in the full user manual.
  • App Language: The app is designed to automatically convert words based on your phone's language and region settings, making it user-friendly for international users.

10. Warranty & Support

The Geevorks 9953W Water Quality Tester comes with a 12-month free replacement warranty for manufacturing defects. For any technical assistance, troubleshooting beyond this manual, or warranty claims, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase for warranty services.

Documents - Geevorks – 9953W

no relevant documents