1. Introduction

The Ecowitt WN34D Thermometer is a high-precision wireless temperature sensor designed for a wide range of applications, including monitoring water temperature in pools and ponds, cold storage, refrigeration units, oil temperature (non-food grade), and soil temperature. It features a durable 1-meter silicone wire sensor and an integrated LCD display for direct readings. This manual provides essential information for setting up, operating, and maintaining your WN34D thermometer.

2. Product Overview

The WN34D consists of a main unit with an LCD display and a connected silicone wire probe sensor. The main unit transmits temperature data wirelessly to compatible Ecowitt gateways or consoles.

Ecowitt WN34D Thermometer front view

Figure 1: Front view of the Ecowitt WN34D Thermometer with its probe.

Ecowitt WN34D Thermometer dimensions

Figure 2: Dimensions of the WN34D main unit and probe sensor.

3. Features

  • Measures temperature with a 1m (3.28ft) cabled sensor.
  • Extended wireless range up to 300 feet (100 meters) in open areas.
  • Wide temperature measurement range: -55°C to 125°C (-67°F to 257°F), utilizing one-wire digital sensor technology.
  • Transmits readings every 77 seconds.
  • IP66 waterproof rating for outdoor and wet environments.
  • LCD display for current temperature readings.

4. Specifications

AttributeValue
Power1x1.5V AA battery (not included)
Sensor typeDS18B20 Single Wire Digital Sensor
FrequencyNorth American: 915MHz; Europe: 868MHz; Other areas: 433MHz
Dimensions (Main Unit)81.5 x 36.2 x 25.3 mm
Probe Sensor Dimensions1000 x 4.8 mm
Screen Size32 x 9.8 mm
Weight92 g
Material of Plastic HousingABS
Material of ScreenTN-LCD
Wireless Transmitting Range100M (300 feet) in open areas
Sensor Reporting Interval77 seconds
Reading Update IntervalAbout 1 minute
Waterproof LevelIP66
Temperature Measurement Range-55°C ~ 125°C (-67°F ~ 257°F)
Accuracy of Temperature Measurement±0.5°C (-10°C ~ 85°C), ±2°C (-55°C ~ -10°C & 85°C ~ 125°C)
Resolution of Temperature Measurement0.1°C (0.2°F)
Operating Temperature Range of LCD Screen-10°C to 50°C (14°F to 122°F)
Operating Temperature Range of Plastic Housing-40°C to 60°C (-40°F to 140°F)
Operating Temperature Range of Probe Sensor-55°C to 125°C (-67°F to 257°F)

5. Package Contents

Ensure all items are present upon unpacking:

  • 1 × WN34D Temperature Sensor Unit
  • 1 × Mounting bracket for sensor
  • 1 × Hose clamp for mounting to pole
  • 1 × Hexagon M12 screw for mounting
  • 1 × Screw ST D3.2*M2.0*6 for mounting
  • 1 × User Manual (this document)

6. Setup

6.1. Battery Installation

  1. Locate the battery compartment on the back of the WN34D main unit.
  2. Open the battery compartment cover.
  3. Insert one (1) 1.5V AA battery, ensuring correct polarity (+/-).
  4. Close the battery compartment cover securely.
Ecowitt WN34D Thermometer back view

Figure 3: Back view of the WN34D, showing battery compartment and mounting points.

6.2. Mounting the Sensor

The WN34D can be mounted using the provided bracket, hose clamp, and screws. Choose a location that allows the probe to measure the desired temperature accurately and is within the wireless range of your Ecowitt gateway/console.

  • For pole mounting: Use the hose clamp to secure the mounting bracket to a pole. Then attach the sensor unit to the bracket using the provided screws.
  • For flat surface mounting: Use the mounting bracket and screws to attach the sensor unit to a wall or other flat surface.

6.3. Pairing with a Gateway/Console

The WN34D is designed to work with various Ecowitt gateways and consoles. The pairing process typically involves:

  1. Ensure your Ecowitt gateway or console is powered on and in pairing mode (refer to your gateway/console manual for specific instructions).
  2. Power on the WN34D by installing the battery. It will automatically attempt to transmit data.
  3. The gateway/console should detect and display the WN34D's temperature readings.
Compatibility with Ecowitt Gateways/Consoles

Figure 4: Diagram showing compatibility of WN34D with various Ecowitt gateways and consoles (GW1100/GW1200, GW2000, WN1820, HP2560, HP2550, WS3800/WS3900) and the Ecowitt APP/ecowitt.net.

7. Operation

7.1. Reading the LCD Display

The integrated LCD display on the WN34D main unit shows the current temperature reading directly. The display updates approximately every minute.

7.2. Wireless Data Transmission

The sensor transmits temperature data wirelessly every 77 seconds. Ensure the sensor is within the 100-meter (300 feet) open-area wireless range of your receiving gateway or console for consistent data updates.

8. Maintenance

8.1. Battery Replacement

When the LCD display becomes dim or the sensor stops transmitting data, it's time to replace the battery. Follow the battery installation steps in Section 6.1.

8.2. Cleaning

The WN34D is IP66 waterproof, meaning it is protected against powerful water jets. You can gently wipe the sensor and probe with a damp cloth to remove dirt or debris. Avoid using abrasive cleaners or solvents.

8.3. Storage

If storing the sensor for an extended period, remove the battery to prevent leakage. Store the unit within its operating temperature range for the plastic housing (-40°C to 60°C / -40°F to 140°F).

9. Troubleshooting

  • No display on LCD: Check battery installation and ensure the battery is fresh.
  • No data received by gateway/console:
    1. Ensure the WN34D has a fresh battery.
    2. Verify the WN34D is within the wireless range of your gateway/console.
    3. Check the compatibility table (Figure 5) to ensure your gateway/console supports the WN34D sensor.
    4. Restart both the WN34D (by removing and reinserting the battery) and your gateway/console.
  • Inaccurate readings: Ensure the probe is fully immersed in the medium you wish to measure (e.g., water, soil) and is not exposed to direct sunlight or other heat sources that could affect its reading.
Ecowitt Sensor Compatibility Table

Figure 5: Detailed compatibility table for Ecowitt sensors and consoles, including the WN34D.

10. User Tips

  • Battery Type: The WN34D requires one 1.5V AA battery. Using a high-quality alkaline battery is recommended for optimal performance and battery life (approximately 12 months minimum).
  • Probe Placement: For accurate water temperature readings, ensure the probe is fully submerged and away from direct sunlight or heating elements. For soil temperature, bury the probe at the desired depth.
  • Wireless Signal: While the sensor has a good range, obstacles like thick walls or metal structures can reduce signal strength. Position your gateway/console optimally for best reception.

11. Warranty and Support

For warranty information, technical support, or service inquiries, please contact Ecowitt customer service or refer to the official Ecowitt website. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.