Hantek 6000 Series

Contents

Hantek 6000 Series USB Virtual Oscilloscope Instruction Manual

Models: 6022BE, 6052BE, 6082BE, 6102BE, 6212BE

1. Introduction

The Hantek 6000 Series USB Virtual Oscilloscope is a high-performance, portable 2-channel device designed for various electrical measurement and analysis tasks. Its robust anodized aluminum casing ensures durability and efficient heat dissipation. This manual provides detailed instructions for setting up, operating, and maintaining your Hantek oscilloscope.

Hantek 6000 Series USB Oscilloscope with certifications
Figure 1: Hantek 6000 Series USB Oscilloscope with CE, FC, RoHS, FDA certifications.

2. Specifications

The Hantek 6000 Series offers various models with differing bandwidths and sample rates. Key specifications are detailed below:

Table of Probe Characteristics for Hantek 6000 Series Oscilloscopes
Figure 2: Probe Characteristics for Hantek 6000 Series Oscilloscopes.

General Specifications:

  • Channels: 2 Channels
  • Input Impedance: 1MΩ 25pF
  • Vertical Resolution: 8Bit
  • Gain Range: 20mV-5V (6022BE), 10mV-5V (other models)
  • DC Accuracy: ±3%
  • Timebase Range: 4ns-5ks
  • Vertical Adjustable: Yes
  • Input Protection: Diode clamping
  • X-Y Mode: Yes
  • EXT Input: No (6022BE), Yes (other models)
  • Trigger Mode: Auto, Normal, Single
  • Trigger Slope: +/-
  • Trigger Level Adjustable: Yes
  • Trigger Type: Rising edge, falling edge
  • Trigger Source: CH1, CH2 (6022BE), CH1, CH2, EXT (other models)
  • Pre/Post Trigger: 0-100%
  • Buffer Size: 1M (6022BE), 10K-64KB/Channel (other models)
  • Sampling Selection: Yes
  • Waveform Display: Port/line, waveform average, persistence, intensity
  • Network: Open/Close
  • Vertical Mode: CH1, CH2, Dual, ADD
  • Cursor Measurement: Yes
  • Math Functions: FFT, addition, subtraction, multiplication, division
  • Cursor: Frequency, Voltage
  • Battery Included: No
  • IS Battery Demountable: No
  • Max Waveform Capture Rate: 30,000wfm/s
  • Record Length: 16k
  • Real Time Sampling Rate: 1GSa/S
  • DIY Supplies: Electrical
  • Display Resolution: 640*480 Pixels
  • Display Size: None

Physical Dimensions:

  • Dimensions (L x W x H): 205mm x 120mm x 35mm
  • Weight: Approximately 55g (for probe)
Dimensions of the Hantek oscilloscope
Figure 3: Physical dimensions of the Hantek 6000 Series Oscilloscope.

3. Setup Guide

3.1 Unpacking and Components

Upon opening the package, ensure all components are present:

  • Hantek 6000 Series USB Virtual Oscilloscope Unit
  • USB Cable
  • Two Probes (switchable X1/X10)
  • Probe Accessories (color rings, locating caps, adjustment tool)
  • Software CD
  • User's Guide (for probes)
Hantek oscilloscope with included accessories
Figure 4: Hantek oscilloscope and its accessories.

3.2 Physical Connections

  1. Connect USB Cable: Plug the USB Type-B connector into the rear of the oscilloscope unit and the other end into your computer's USB port. The device is powered via USB, requiring no external power source.
  2. Connect Probes: Attach the BNC connectors of the probes to the CH1 and CH2 inputs on the front of the oscilloscope.
  3. Probe Ground: Connect the ground clamp of the probe to the ground reference point of your circuit.
  4. Probe Tip: Attach the grabber tip to the square wave generator output for testing.
Front and back view of the Hantek oscilloscope showing USB ports and BNC channels
Figure 5: Front and back view of the oscilloscope, showing USB ports and BNC channels.

3.3 Software Installation

Insert the provided mini CD into your computer's CD drive. Follow the on-screen instructions to install the Hantek oscilloscope software. The software is compatible with Windows 10, Windows 8, Windows 7, Windows NT, Windows XP, and VISTA.

Video 1: Demonstration of the Hantek 6022BE unit and software interface.

4. Operating Instructions

4.1 Software Interface Overview

The Hantek oscilloscope software provides a user-friendly interface for waveform analysis. The main screen displays the waveform, with control panels for horizontal and vertical adjustments, trigger settings, and various measurement tools.

4.2 Basic Operation

  1. Auto Setup: For quick configuration, click the 'Auto Setup' button (often labeled 'AUTO' or similar icon). This automatically adjusts the time/division and voltage/division settings to display a stable waveform.
  2. Horizontal Adjustments: Use the 'Time/Div' control to adjust the horizontal scale (time per division). This can be done via a menu or a rotary knob in the control panel.
  3. Vertical Adjustments: Use the 'Volt/Div' control for each channel (CH1, CH2) to adjust the vertical scale (voltage per division). You can also select DC or AC coupling and invert the signal.
  4. Probe Attenuation: Ensure the software setting for probe attenuation (e.g., x1, x10) matches the physical switch on your probe.

4.3 Trigger Settings

The trigger function stabilizes repetitive waveforms and captures single-shot events.

  • Trigger Mode: Select between Edge, Pulse, Video, etc. (Edge is common for general use).
  • Trigger Source: Choose the channel (CH1, CH2, or EXT) that the trigger will monitor.
  • Trigger Slope: Set to Rising (+), Falling (-), or Both (+/-) edges.
  • Trigger Level: Adjust the trigger level to specify the voltage point at which the trigger event occurs.

4.4 Display Options

Customize the waveform display for better analysis:

  • Type: Choose between Vectors (lines connecting points) or Dots (individual sample points).
  • Grid: Toggle the display of the grid for easier measurement.
  • Intensity: Adjust the brightness of the waveform display.

4.5 Measurements and Math Functions

The software includes various measurement and math functions to analyze waveforms:

  • Cursors: Use vertical (time/frequency) and horizontal (voltage) cursors to take precise measurements. A cross cursor is also available for simultaneous measurements.
  • Math Operations: Perform operations like A+B, A-B, A×B, A/B between channels.
  • FFT (Fast Fourier Transform): Analyze the frequency components of your signal.

5. Maintenance

5.1 General Care

  • Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
  • Avoid exposing the oscilloscope to extreme temperatures, humidity, or direct sunlight.
  • Store the device in a safe place when not in use to prevent physical damage.

5.2 Probe Compensation

Before taking any measurements using a probe, first check the compensation of the probe and adjust it to match the channel inputs. Most oscilloscopes have a square wave reference signal available on a terminal on the front panel (or via software). Connect the probe to the signal source on your oscilloscope. Set the probe to 10X position. Adjust trimmer until seeing flat-top square wave on the display.

Diagram showing correct and incorrect probe compensation waveforms
Figure 6: Visual guide for probe compensation, showing incorrect (under-compensated, over-compensated) and correct waveforms.

6. Troubleshooting

  • No Waveform Display: Ensure the USB cable is securely connected to both the oscilloscope and the computer. Verify that the software is running and the correct channels are enabled. Check probe connections and ensure they are properly grounded.
  • Unstable Waveform: Adjust the trigger settings (mode, source, level, slope) to stabilize the waveform. Using the 'Auto Setup' function can often resolve this quickly.
  • Distorted Waveform: Perform probe compensation as described in Section 5.2. Check for damaged probes or cables.
  • Software Not Recognizing Device: Reinstall the software from the provided CD. Ensure your operating system is compatible. Try connecting to a different USB port.

7. User Tips

  • For optimal display, always use the 'Auto Setup' feature first, then fine-tune the settings manually.
  • Utilize the color-coded rings on the probes to easily identify which probe is connected to which channel.
  • When performing measurements, ensure proper grounding to avoid noise and inaccurate readings.
  • Experiment with the various math functions (A+B, A-B, A*B, A/B, FFT) to gain deeper insights into your signals.

8. Support

For further assistance or technical support, please refer to the contact information provided by your retailer or the manufacturer's official website.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.