OBO HANDS K7612

Contents

OBO HANDS K7612 RFID Metal Access Control Keypad User Manual

Model: K7612

1. Introduction

The OBO HANDS K7612 is a high-quality, standalone RFID metal access control keypad designed for secure door access. It features a durable zinc alloy construction, low power consumption, and a user-friendly interface. This system supports up to 1000 users and offers three distinct unlock methods, making it suitable for various applications including households, offices, apartments, and factories. The keypad can be installed outdoors when used with the provided rainproof cover.

RFID Metal Access Control Keypad with 10 blue keyfobs and rainproof cover
Figure 1: OBO HANDS K7612 RFID Metal Access Control Keypad with included keyfobs and rainproof cover.

2. Product Features

  • High quality and high security design.
  • Sensitive and quick response time.
  • Supports up to 1000 standard users.
  • Integrated doorbell button and backlit digital keypad for visibility in low light.
  • Equipped with WG26 interface for external reader connection.
  • Features two relay outputs for versatile control.
  • Includes time delay and tamper alarm functions for enhanced security.
  • Supports three unlock methods: RFID card, password, or a combination of RFID card + password.
  • Classical appearance suitable for various environments.
  • Professional design ideal for home and office use.
  • Designed for single-door access control.
  • Functions as a standalone keypad, no computer connection required for operation.
  • Applicable for home, hotel, office, apartment, factory, and similar settings.

3. Product Specifications

Feature Specification
Model Number K7612
Brand Name OBO HANDS
Material Zinc Alloy
Working Voltage DC 12V
Working Frequency 125KHz
WG Interface WG26
User Card Capacity 1000
Backlight Function Supported
Door Bell Function Supported
Relay Outputs 2 relays
Dimensions (L*H*W) 77mm * 120mm * 27mm
Working Current 1.2A
Working Temperature -20°C to +70°C
Reading Distance 0-10cm
Relative Humidity 20%-90%

4. Product Details and Components

The K7612 access control keypad is constructed from eco-friendly zinc alloy, ensuring durability and resistance against vandalism and tampering. Its design is robust for various environmental installations.

Close-up of the keypad with blue backlight, showing digital buttons, card area, and doorbell button.
Figure 2: Front view of the keypad, highlighting the digital buttons, card reading area, doorbell button, and work indicators.

The keypad features a blue backlight for easy operation in dark conditions. All programming can be performed directly on the keypad.

4.1. RFID Keyfobs

The system includes 10 EM4100 RFID keyfobs for convenient access. Each keyfob operates at 125KHz and has a unique ID number. Only programmed keyfobs can open the door.

Image of 10 blue RFID keyfobs.
Figure 3: Included EM4100 RFID Keyfobs.

4.2. Rainproof Cover

For outdoor installations, a rainproof cover is provided to protect the access control keypad from weather elements. While the K7612 model can withstand some surface water, direct rain exposure requires the cover for optimal protection.

  • Outside Dimensions: 15cm (L) * 10.4cm (W) * 9cm (H)
  • Inside Dimensions: 13.5cm (L) * 8.9cm (W) * 8.4cm (H)
Rainproof cover dimensions (top view: 15cm L, 10.4cm W, 9cm H).
Figure 4: Top view of the rainproof cover with dimensions.
Rainproof cover dimensions (side view: 13.5cm L, 8.9cm W, 8.4cm H).
Figure 5: Side view of the rainproof cover with dimensions.
Image showing the access control keypad with rainproof cover installed outdoors in various weather conditions (rain, sun, snow, fog, lightning).
Figure 6: Keypad with rainproof cover in various outdoor conditions.

5. Setup and Installation

The K7612 access control keypad operates independently and does not require a computer connection for basic functionality. Installation involves connecting the keypad to a DC12V power supply, an electric lock, and an exit button. A doorbell can also be integrated.

Note: The power supply, electric lock, exit button, and doorbell are NOT included in the package and must be purchased separately.

5.1. Wiring Diagram

Refer to the following diagrams for proper wiring connections. Ensure all connections are secure and correctly matched to avoid damage to the device or connected components.

Simplified wiring diagram showing connection of access controller, power supply, magnetic lock, and exit button.
Figure 7: Simplified wiring diagram for basic access control setup.
Detailed wiring diagram for the back of the access control machine, showing connections for lock relay output, alarm relay output, power supply, door bell, exit button, and Wiegand reader.
Figure 8: Detailed wiring diagram for the K7612 keypad's rear connections.

Wiring Terminal Descriptions:

  • +12V, GND: Power input (DC 12V)
  • PUSH/NO, OPEN/SW, DOOR1: Connections for exit button and door sensor.
  • BELL, BELL: Doorbell connections.
  • AUX-IN: Auxiliary input.
  • GND, DATA0, DATA1: Wiegand 26 interface for external reader.
  • COM, NO, NC: Lock relay output (for electric lock).
  • ACU-COM, NO, NC: Alarm relay output.

6. Operating Instructions

The K7612 offers flexible access methods and programming directly from the keypad.

6.1. Unlock Methods

Users can gain access using one of three methods:

  1. RFID Card: Present a programmed RFID card to the card reading area on the keypad.
  2. Password: Enter a valid 4-digit password on the keypad.
  3. RFID Card + Password: Present a programmed RFID card, then enter the corresponding password.
Access control keypad with rainproof cover, showing RFID card, password, and combined unlock methods.
Figure 9: Illustration of the three unlock methods.

6.2. Programming

All user management and system settings, including adding/deleting users, changing passwords, and configuring relay settings, are performed directly through the keypad. Refer to the detailed programming guide (usually included in the physical manual or available from the manufacturer) for specific steps on entering programming mode and executing commands.

General Programming Steps (Consult full manual for details):

  1. Enter Programming Mode (e.g., by entering a master code).
  2. Select desired function (e.g., Add User, Delete User, Change Password).
  3. Follow on-screen prompts or indicator lights to complete the action.
  4. Exit Programming Mode.

7. Maintenance

  • Cleaning: Wipe the keypad surface with a soft, dry cloth. Avoid abrasive cleaners or solvents that could damage the finish or electronics.
  • Outdoor Protection: Always ensure the rainproof cover is correctly installed and securely fitted if the keypad is mounted outdoors. Regularly check the cover for any damage or cracks that could compromise its protective function.
  • Power Supply: Ensure a stable DC 12V power supply is used. Fluctuations can affect performance and longevity.
  • Cable Integrity: Periodically inspect all wiring for signs of wear, damage, or loose connections.

8. Troubleshooting

  • Keypad Not Responding: Check the power supply connection. Ensure the working voltage is DC 12V.
  • Door Not Unlocking:
    • Verify that the RFID card or password entered is correct and properly programmed.
    • Check the wiring to the electric lock and ensure it is receiving power and signal from the keypad.
    • Ensure the lock mechanism itself is not jammed or faulty.
  • Tamper Alarm Activation: The system features a tamper alarm. If the keypad is forcibly removed or tampered with, the alarm will activate. Ensure the device is securely mounted to prevent false alarms.
  • Backlight Not Working: Check power connections. If the issue persists, it may indicate an internal fault.
  • RFID Cards Not Reading: Ensure the cards are 125KHz EM4100 compatible and properly programmed into the system. Check the reading distance (0-10cm).
Image depicting a tamper alarm scenario with a person attempting to remove the device.
Figure 10: Tamper alarm function in action.

9. User Tips

  • Outdoor Installation: For optimal longevity and performance in outdoor environments, always use the provided rainproof cover. While the device is robust, the cover adds an essential layer of protection against harsh weather.
  • Multi-Door Control: The K7612 is designed as a single-door access controller. While it has two relay outputs, these are typically used for primary lock control and an auxiliary function like an alarm. If you require control for multiple doors with separate codes, consider a multi-door access control system or multiple standalone units.
  • Keyfob Management: Keep a record of your keyfob IDs and programmed passwords. This will be helpful for adding new users or troubleshooting lost/stolen keyfobs.
  • Power Supply Quality: Invest in a reliable and stable DC 12V power supply to ensure consistent operation and prevent potential issues caused by power fluctuations.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

11. Product Overview Video

Watch this video for a visual overview and demonstration of the OBO HANDS K7612 RFID Access Control Keypad.

Play video
Watch video online
Video 1: OBO HANDS K7612 Product Overview.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.