1. Introduction
The HABOTEST HT5205 is a high-precision digital insulation tester and multimeter designed for electrical professionals and DIY enthusiasts. This versatile instrument combines the functions of a megohmeter, voltmeter, and resistance meter, offering a wide range of measurement capabilities. It features a high-definition LCD with backlight for clear readings in various environments, timed measurement, data hold, and automatic shutdown for energy efficiency.

The HT5205 is built to conform with EN61010-1, EN61326-1, EN61557-5 standards, and is rated 1000V CAT III / 600V CAT IV, ensuring safety and reliability in demanding electrical applications. Its durable and impact-resistant casing provides robust protection.
2. Safety Information
WARNING: To avoid electrical shock, remove test leads before opening the case or battery cover. Please read the entire manual for safety instructions before use.
- Always ensure the instrument is in good working condition before use.
- Do not use the instrument if it appears damaged or if the insulation on the test leads is compromised.
- Ensure the correct function and range are selected for the measurement being performed.
- Do not apply voltage to the input terminals that exceeds the maximum rated value.
- Always disconnect the test leads from the circuit under test before changing functions or ranges.
- Wear appropriate personal protective equipment (PPE) when working with electrical systems.
- The device is rated for Pollution Degree 2 environments.
3. Product Overview
3.1 Instrument Panel

- Input Socket
- Display Screen
- Insulation Resistance Measurement Button (TEST)
- Timer Function Button (TIMER)
- Insulation Resistance Comparison Function Button (COMP.)
- Conversion/Absorption Ratio/Polarization Index/AC-DC Voltage Switch Button (DAR/PI AC/DC)
- Power On/Off/Function Switch Knob
- Data Storage/Data Read (MEMO READ)
- Data Hold/Backlight (HOLD *)
- Maximum/Minimum Value (MAX MIN)
3.2 Input Terminal Description

| Input Terminal | Description |
|---|---|
| LINE | Positive input terminal for measuring insulation resistance. |
| VΩ | Positive input terminals for measuring AC/DC voltages. |
| G | ① Negative input terminal for measuring AC/DC voltage. ② The input terminal for measuring continuity at the ))) Ω position. |
| EARTH | ① Negative input terminal for measuring insulation resistance. ② The input terminal for measuring continuity at the ))) Ω position. |
3.3 Function Icons

- Automatic shutdown: Device powers off after a period of inactivity.
- Insulation resistance data storage/read: Save and recall measurement data.
- Data hold: Freeze the current reading on the display.
- Backlight function: Illuminates the display for visibility in low light.
- Maximum/Minimum value: Records the highest and lowest readings during a measurement.
- Insulation resistance comparison function: Compares current readings against a set reference.
- Insulation resistance timed measurement function: Performs insulation tests for a specified duration.
- Buzzer alert: Provides audible feedback for continuity and other functions.
- Dielectric Absorption Ratio (DAR)/Polarization Index (PI): Advanced insulation testing features.
- Low battery voltage indication: Alerts when battery power is low.
- AC/DC voltage measurement: Measures both alternating and direct current voltages.
- Continuity measurement: Checks for electrical continuity in a circuit.
4. Setup
4.1 Battery Installation
The HT5205 is powered by 8x1.5V AA(LR) batteries. Batteries are not included in the product package.
- Locate the battery compartment on the back of the device.
- Use a suitable tool to open the battery cover.
- Insert 8x1.5V AA(LR) batteries, ensuring correct polarity (+/-).
- Securely close the battery cover.

5. Operating Instructions
5.1 AC/DC Voltage Measurement
To measure AC or DC voltage:
- Rotate the rotary switch to the AC/DC-V position.
- Press the 'DAR/PI AC/DC' button to switch between AC and DC voltage measurement modes as needed.
- Insert the red test lead into the V terminal and the black test lead into the G terminal.
- Connect the test leads to the circuit or power source to be tested.
- Read the measurement results from the display screen.

5.2 Insulation Resistance Timed Measurement
For timed insulation resistance tests:
- Adjust the function switch knob to the desired insulation test voltage (e.g., 100V, 250V, 500V, 1000V, 2500V).
- Connect the test leads to the device under test, ensuring the red lead is in the LINE terminal and the black lead is in the EARTH terminal.
- Press the 'TIMER' button to activate the timed measurement function.
- Press the 'TEST' button to initiate the insulation test.
- The instrument will perform the test for the set time and automatically stop.
- Read the insulation resistance value from the display.

5.3 Continuity Measurement
To check for continuity:
- Rotate the switch knob to the '))) Ω' position.
- Insert the red test lead into the EARTH terminal and the black test lead into the G terminal.
- Connect the test leads to the object being measured.
- Read the measurement results from the display screen.
- The buzzer will sound if the measured resistance is less than 500Ω, indicating continuity. The measurement range is 0.19Ω to 200.0Ω.

5.4 Equipment Insulation Test
To perform an equipment insulation test:
- Adjust the function switch knob to the appropriate voltage range for the insulation test.
- Insert the red meter pen into the LINE terminal of the instrument.
- Insert the black meter pen into the EARTH terminal of the instrument.
- Connect the test leads to the device to be tested.
- Press the 'TEST' button to begin the measurement.

5.5 Product Demonstration Video
6. Specifications
| Feature | Value/Range | Accuracy |
|---|---|---|
| Model Number | HT5205 | |
| Display Type | Digital Only | |
| DIY Supplies | Electrical | |
| Certification | CE | |
| Dimensions | 180X140X65mm | |
| Product Weight | 627g | |
| Security Level | IEC/EN 61010-1 1000V CAT III / 600V CAT IV | |
| Power Supply | 8x1.5V AA(LR) Batteries (not included) | |
| Testing Voltage | 0-2500V | |
| Resistance Measuring Range | 0~200GΩ | |
| DC Voltage | 0-1000V | ±(1.0%reading+5word) |
| AC Voltage | 0-750V | ±(1.0%reading+5word) |
| Data Hold | Yes | |
| MAX/MIN/AVG | Yes | |
| Backlight | Yes | |
| Low Battery Indication | Yes | |
| Auto Power off | Yes | |
| DAR/PI index measurement | Yes | |
| Timing measurement function | Yes | |
| Numerical comparison function | Yes | |
| Data saving and reading functions | Yes | |
| Beep | Yes |


7. Maintenance
- Cleaning: Use a soft, damp cloth to clean the instrument's casing. Do not use abrasive cleaners or solvents.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- Battery Replacement: When the low battery indicator appears, replace all 8x1.5V AA(LR) batteries promptly to ensure accurate readings and prevent potential electrical hazards. Refer to Section 4.1 for battery installation instructions.
- Test Leads: Regularly inspect test leads for any signs of damage, such as cracks or frayed insulation. Replace damaged leads immediately.
- Casing: The HT5205 features a durable and impact-resistant casing. While robust, avoid dropping the device or subjecting it to excessive force to maintain its integrity.

8. Troubleshooting
- Device Not Powering On: Check if the batteries are correctly installed and have sufficient charge. Replace batteries if necessary.
- Low Battery Indication: If the battery symbol appears on the display, it indicates low battery power. Replace the batteries promptly to avoid incorrect readings and potential electrical hazards or personal injuries.
- Auto Power Off: The device features an automatic shutdown function to conserve battery life. If the device turns off unexpectedly, it might be due to inactivity. If it persists after active use, check battery levels.
- Inaccurate Readings: Ensure test leads are properly connected and not damaged. Verify that the correct function and measurement range are selected for the task. Check battery levels.

9. User Tips
- Select Correct Range: Always start with a higher measurement range and decrease it if necessary to get a more precise reading, especially for voltage and resistance measurements. The function knob allows for multiple measurement ranges.
- Utilize Data Hold: Use the 'HOLD' button to freeze a reading on the display, which is useful when taking measurements in hard-to-reach areas or when you need to record a value.
- Backlight for Visibility: Activate the backlight function in dimly lit environments to ensure clear visibility of the LCD display.
- Memory Function: Take advantage of the data storage and read functions ('MEMO READ') to save multiple sets of data for later review or comparison.
- Safety First: Always prioritize safety. Double-check connections and ensure the circuit is de-energized before performing resistance or continuity tests, unless specifically testing live circuits with appropriate safety precautions.


10. Warranty and Support
This HABOTEST HT5205 Digital Insulation Tester Multimeter comes with a 1-year warranty from the HABOTEST Brand Store. For technical support, warranty claims, or any inquiries regarding the product, please contact the seller or manufacturer directly.
Package Contents:

- HT5205 Digital Insulation Tester
- Packing & Bag
- Detection Pen (Test Leads)
- Alligator Clips
- English Manual