Introduction
Thank you for purchasing the M8P balance charger. Please read this manual carefully before use to ensure proper operation and safety.
The M8P is a multifunctional tool that integrates functions such as a balance charger and discharger, a signal measuring device, and a signal source.
For further information, news, and firmware updates, please visit the official ToolkitRC website: www.toolkitrc.com.
Safety Warnings
⚠ WARNING:
- The M8P allows an input voltage of DC 7.0-35.0V. Ensure the charger is only connected to a suitable power source and with correct polarity.
- Do not use this product in hot, humid, flammable, or explosive environments.
- Please do not use this charger without supervision. Never leave charging batteries unattended.
- When not using this product, please unplug the input power.
- When using the charging function, please set a current that matches the battery. Do not set an excessive current for charging to avoid damage to the battery. Check the guidelines of your battery's manufacturer for correct charging instructions.
- This product can expose you to chemicals including phthalates (DEHP), which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Product Overview and Layout
The ToolkitRC M8P is a versatile multi-charger designed for various RC applications. It features a 2.4-inch IPS color display and an intuitive scroll wheel for navigation.
Video: Demonstration of the M8P charger's interface and settings.
Figure 1: ToolkitRC M8P Multi-Charger with included accessories.
Figure 2: Front view of the M8P charger, showing the display, output port, balance port, signal port, scroll wheel, and Exit button.
Figure 3: Back view of the M8P charger, showing the USB-A output, DC 7-35V input port, and cooling fan.
The M8P is more than just a charger; it's an all-in-one toolkit:
Figure 4: M8P Multifunctions.
Setup: Quick Start Guide
- Connect a 7-35V DC power supply to the input port on the back of the M8P.
- The display will show the boot logo for 2 seconds, followed by a welcome sound.
- After booting, the screen enters the main interface.
Figure 5: M8P Main Interface.
Interface Navigation:
- Press and hold [Exit] to enter the auxiliary function interface.
- Scroll the [Scroll Wheel] to switch between pages.
- With the charger idle, short press the [Scroll Wheel] to set charging parameters. During charging, short press to adjust amperage or stop the charge.
- With the charger idle, press and hold [Scroll Wheel] to enter the system setting interface.
- Short press [Exit] to return to the previous interface.
Operating Instructions: Charge and Discharge Settings
From the main interface, select and short press the [Scroll Wheel] to enter the charging function. Open the battery selection option in system settings to display the following interface:
Figure 6: Battery Selection Menu.
1. Battery Type Setting
Scroll the [Scroll Wheel] to select a preset or create a new battery profile. Up to 32 battery files can be created. Short press the [Scroll Wheel] to enter specific battery settings.
Figure 7: Battery Type Selection.
The charger supports charging and discharging of 6 types of batteries: LiPo, LiHV, LiFe, Lion, LTO (1-8S), NiMh (1-20S), and Pb (1-10S). There is also a smart battery mode.
⚠ Warning: Ensure the correct battery type is selected prior to charging to prevent damage or fire hazards.
2. Cell Setting
Move the cursor to [Cells] and short press the [Scroll Wheel] to modify the number of cells.
Figure 8: Cell Count Setting.
Rotate the [Scroll Wheel] to adjust the value. When set to [Auto], the charger automatically identifies the number of cells by checking the total voltage against the balance port data. Short press the [Scroll Wheel] and [Exit] to save.
Tips:
- If the connected battery is over-discharged or over-charged, this may cause an incorrect cell-count. Adjust manually if needed.
- Incorrect cell count can lead to overcharging and fire risk.
- Connecting the balance port improves cell count accuracy.
3. Work Mode
Move the cursor to [Mode] and short press the [Scroll Wheel] to modify the work mode.
Figure 9: Work Mode Selection.
Available modes: Charge, DisCHG (Discharge), StoCHG (Storage Charge).
4. Discharge Mode
Under discharge, storage, and cycle modes, the option for discharging the battery will appear. Move the cursor to [Discharge Mode] and short press the [Scroll Wheel] to modify.
The charger supports three discharge modes:
- Normal mode: Discharge using internal heat dissipation, max 3.0A@20W.
- Recycle mode: Recovers power to the input battery when a battery is used as input, max 20.0A@600W.
- External mode: Discharges through an external load connected to the input port and battery connected to the output port, max 20.0A@600W.
5. Max Input Voltage
When Recycle discharge mode is selected, the [Max Input Vol.] option appears. Adjust this value using the [Scroll Wheel]. Discharge will stop if the input voltage reaches this value.
Tips:
- Set Max input voltage to the highest protection voltage of your power supply. High overvoltage settings can damage the input power source.
6. End Voltage Setting (TVC)
Move the cursor to [End Voltage] and short press the [Scroll Wheel] to modify the end voltage for individual cells. When charging, this is the charge cut-off voltage (range: +/- 50mV of full voltage). When discharging, it is the discharge cut-off voltage (adjust in 0.01V steps).
Notes:
- Only LiPo, LiHV, LiFe batteries can set the cut-off voltage.
- Do not modify cut-off voltage if unfamiliar with battery characteristics.
- TVC: Terminal Voltage Control.
7. Current Setting
Move the cursor to [Charge Current] or [DisCHG Current] and short press the [Scroll Wheel] to modify the current. Adjust in 0.1A steps. The charger supports up to 10.0A.
Tips:
- Set the charging rate to 1-2C according to battery capacity (e.g., 2000mAh battery = 2.0-4.0A charge current).
- Charge/discharge current is only valid in the corresponding work mode.
8. NiMH Setting (PeakV)
For NiMH batteries, set the PeakV value (5mV-15mV) which is the maximum voltage drop per cell when the battery is fully charged.
9. Cycle Setting
For NiMh batteries in cycle mode, options for Cycle time (2-12) and Rest time (2-10 minutes) will appear. The charger follows a discharge->charge pattern.
10. External Load Setting
When external discharge is selected, set the wattage according to the external load used.
11. Smart Battery Setting
When UAV battery is selected, options are drone type (Mavic2, MavicS, Phantom, Inspire) and Max current (0.5A to 20A).
Other Functions (Accessibility)
After selecting and long pressing [Exit] in the main interface, you can enter the auxiliary function interface, which includes:
- Measure resistance: Short press [Scroll Wheel] to test internal resistance.
- Measure signal: Enter signal test interface. Scroll [Scroll Wheel] to select signal type (PWM, PPM, SBUS).
- Signal output: Enter signal output interface. Scroll [Scroll Wheel] to select signal type (PWM, PPM, SBUS) and adjust values.
- ESC test: Enter ESC test mode. Scroll [Scroll Wheel] to adjust pulse width/cycle.
- Power: Adjustable power supply. Set voltage and current. Short press [Scroll Wheel] to start power output.
System Settings
Press and hold [Scroll Wheel] from the main interface to enter system settings. Short press to expand settings.
- Input settings: Power selection (P1, P2, P3), Power type (Battery pack, Adapter), Max power (e.g., 90W), Max current (e.g., 12.0A), Voltage range (e.g., 7.0-24.0V).
- Security settings: Safe inter Temp. (internal temperature limit, e.g., 70°C), Safe Exter Temp. (environment temperature limit, e.g., 50°C), Safe time (continuous operation limit, e.g., 200Min), Safe capacity (accumulated capacity limit, e.g., 20Ah).
- Personalization: Backlight (1-10), Operation volume (Off, Low, Medium, High), Announce volume, Warning volume, Language (English, Chinese, etc.), Theme style (Light, Dark).
- Battery selection: Option to show/hide frequently used parameters.
- Work completed: Whether to stop or trickle charge after charging is complete.
- Balance start Vol: Balance cells prior to full current charge.
- Continuous work: Enables/disables continuous charging/discharging after battery replacement.
- Default: Reset factory settings.
- ID: Independent ID for each device.
Other Functions
1. Firmware Upgrade
Connect the M8P to a computer using the USB cable. The computer will recognize a USB drive named 'Toolkit'. Download the upgrade file (app.upg) from www.toolkitrc.com and overwrite the files in the drive to upgrade the firmware.
2. Automatically Continue Charging/Discharging
When a battery is fully charged, connect the next battery. The device will automatically continue to charge and discharge. This function can be started and stopped in the settings menu.
3. Fan Level
- Internal temperature > 45°C: Fan turns at half speed to reduce noise.
- Internal temperature > 53°C: Fan turns on full speed for enhanced heat dissipation.
4. Manual Voltage Calibration
With the M8P powered off, press and hold the [roller]. Without releasing, connect the power supply. The system will enter manual voltage calibration mode. Use a voltmeter to measure the actual voltage of each battery. Move the cursor to the corresponding voltage value and modify it to match the voltmeter value. After calibration, move the cursor to save, short press once, and the buzzer will beep once.
5. Full Charge Mode
When a lithium battery is fully charged, it will prompt "Fast charge complete". If the battery is not removed, the charger will trickle charge until disconnected.
Maintenance
- Keep the device clean and free from dust and debris.
- Avoid exposing the charger to extreme temperatures, humidity, or direct sunlight.
- Always unplug the power supply when the charger is not in use.
- Store the charger in a dry, safe place.
Troubleshooting
- Charger not powering on: Ensure the DC input voltage is within 7-35V and polarity is correct. Check power supply connection.
- Battery not charging/discharging correctly: Verify the correct battery type and cell count are selected in the settings. Ensure the charge/discharge current is appropriate for the battery. Check all connections, including balance leads.
- Overheating: Ensure the cooling fan is not obstructed. Operate in a well-ventilated area. If internal temperature warnings persist, reduce charge/discharge current.
- Error messages: Refer to the specific error code or message on the display for guidance. Often related to incorrect battery settings or connection issues.
Specifications
Figure 10: M8P Detailed Parameter Table.
| Category | Parameter | Value |
|---|---|---|
| Charge | Input | 7-35V@MAX25A |
| Battery Type | LiPo, LiHV, LiFe, Lion, LTO@1-8S; NiMh@1-20S; Pb@1-10S | |
| Balance Current | 1000mA @4.2V | |
| Accuracy | <0.005V | |
| Power | 0.1-20A@600W | |
| Discharge Power | 0.1-20A@600W Rec/Ext Mode; 0.1-3A@20W Internal Mode | |
| USB A | 2.1A@5.0V upgrade | |
| Voltage | 1.0V-5.0V @1-6S | |
| Internal Resistance | 0.1mΩ-99Ω @1-8S | |
| Measure | PWM | 880us-2200us@20-400Hz |
| PPM | 880us-2200us*8 CH@20-50Hz | |
| SBUS | 880us-2200us*16 CH@20-100Hz | |
| Output | PWM | 500us-2500us@20-1000Hz |
| PPM | 880us-2200us*8 CH@50Hz | |
| SBUS | 880us-2200us*16 CH@74Hz | |
| Power | 1-20A@1-35V Mode: CC+CV | |
| Display | LCD | IPS 2.4 inch 320*240 resolution |
| Product | Size | 99mm*72mm*35mm |
| Weight | 180g | |
| Individual Packing | Size | 125mm*81mm*41mm |
| Weight | 250g |
ADP100 AC to DC Adapter Specifications:
Figure 11: ADP100 Adapter Specifications.
| Parameter | Value |
|---|---|
| Input voltage | AC 100-240V 50/60Hz |
| Input current | MAX 1A |
| Output voltage | MAX 20.0V |
| Output current | MAX 5.0A |
| Connector | XT60 |
| Size | 90mm * 90mm * 32mm |
| Weight | 215g |
| Work temp | -10 - 40°C |
User Tips
- The M8P charger includes a screen protector for added durability.
- The device supports multiple languages, including English, Spanish, and Korean, which can be changed in the personalization settings.
- The intuitive scroll wheel provides excellent tactile feedback for easy navigation through menus.
- The improved heat dissipation design ensures safer and higher efficiency during operation.
Warranty and Support
For detailed warranty information and technical support, please refer to the official ToolkitRC website: www.toolkitrc.com.
You can also view the official user manual in PDF format for comprehensive guides and documents: M8P User Manual (PDF).