BEVOTOP MCX Male to C5 Cable

BEVOTOP MCX Male to C5 Cable User Manual

Model: MCX Male to C5 Cable

Brand: BEVOTOP

1. Product Overview

The BEVOTOP MCX Male to C5 Cable is a high-quality RF coaxial cable designed for reliable signal transmission in various applications. It features an MCX Male connector on one end and an FFA 00S C5 Male Plug on the other, utilizing RG316 RF coaxial cable with a 50 Ohm impedance. This cable is particularly suitable for use with ultrasonic flaw detectors, acceleration sensors, and other specialized equipment.

BEVOTOP MCX Male to C5 Cable with FFA 00S Connector
Figure 1: BEVOTOP MCX Male to C5 Cable with FFA 00S Connector (Straight MCX Male shown).
MCX to C5 Cable Product Overview
Figure 2: Overview of MCX to C5 Cable variants.

2. Specifications

2.1 General Specifications

FeatureDescription
Product NameMCX to C5 Cable
Connector AFFA 00S C5 Male Plug
Connector BMCX Male (Straight or Right Angle)
Cable TypeRG316 RF Coaxial Cable
Impedance50 Ohm
Connector PlatingNickel Plated
Cable Length Options10cm to 10M (customizable)
ApplicationUltrasonic flaw detector, acceleration sensor, GSM system, GPS navigation system, Wireless communication system, Antennas, Car radio, Test equipment, Microwave components, Data transmission, LAN system, Satellite transmission, Aviation equipment, etc.
CustomizationAvailable for cable type, length, and connector types.
OriginMainland China
CertificationNONE

2.2 RG316 Cable Construction

RG316 Cable 50 Ohm Construction Diagram
Figure 3: RG316 Cable 50 Ohm Construction Diagram.
ComponentMaterialDiameter (mm)
Inner ConductorSilver Covered Copper7/0.175
InsulationPTFEΦ1.52
Outer ConductorSilver Covered CopperΦ1.95
JacketFEPΦ2.54

2.3 Connector Performance Parameters

Connector Performance Parameters (Mechanical, Electrical, Other)
Figure 4: Detailed performance parameters for the connector.
CategoryParameterValue
Mechanical PerformanceShell MaterialCopper alloy nickel plating
Contact MaterialBeryllium copper gold plating
Insulation MaterialPTFE
Service Life5000+ cycles
Electrical PerformanceContact Resistance≤12.5 mΩ
Insulation Resistance5000 MΩ (normal)
Withstand Voltage750V (sea level)
Rated Working Current3.8A
Other PerformanceWorking Temperature-55°C ~ +150°C
Relative Humidity90%~95% (40±2°C)
Salt Spray Test72h
Waterproof RatingHead insertion IP50

3. Installation and Connection

This cable is designed for straightforward connection between compatible devices. Ensure that the connectors on your equipment match the MCX Male and FFA 00S C5 Male Plug types.

3.1 Identifying Connectors

  • MCX Male Connector: This is the smaller, push-on/pull-off connector. It can be straight or right-angle.
  • FFA 00S C5 Male Plug: This is a precision connector, often used in test and measurement equipment.
FFA 00S Male to MCX Male Straight Cable
Figure 5: Cable with FFA 00S Male and MCX Male Straight connectors.
FFA 00S Male to MCX Male Right Angle Cable
Figure 6: Cable with FFA 00S Male and MCX Male Right Angle connectors.

3.2 Connection Procedure

  1. Identify the appropriate ports on your ultrasonic flaw detector or other compatible device.
  2. Align the FFA 00S C5 Male Plug with the corresponding female receptacle on your equipment. Push firmly until it clicks into place, ensuring a secure connection.
  3. Align the MCX Male connector with its mating female receptacle. For straight connectors, push directly. For right-angle connectors, ensure proper orientation before pushing. The MCX connector is typically a push-on type.
  4. Verify that both ends of the cable are securely connected to prevent signal loss or intermittent operation.

4. Operation

Once the cable is securely connected, it facilitates the transmission of RF signals between your devices. No specific operational steps are required for the cable itself beyond ensuring a proper connection. The cable is passive and designed for reliable signal integrity.

4.1 Best Practices for Signal Integrity

  • Avoid sharp bends or kinks in the cable, as this can damage the internal conductors and affect performance.
  • Do not overtighten connectors, especially the FFA 00S type, to prevent damage to the mating surfaces.
  • Keep connectors clean and free from dust or debris. Use appropriate cleaning methods for RF connectors if necessary.
  • Ensure the cable length is appropriate for your application to minimize signal attenuation.

5. Maintenance and Care

Proper maintenance will extend the lifespan and ensure optimal performance of your BEVOTOP RF coaxial cable.

  • Cleaning: Periodically inspect the connectors for dirt or corrosion. Use a lint-free cloth and a small amount of isopropyl alcohol to gently clean the contact surfaces if needed. Ensure connectors are dry before re-connecting.
  • Storage: Store the cable in a clean, dry environment, away from extreme temperatures and direct sunlight. Avoid coiling the cable too tightly.
  • Inspection: Regularly check the cable jacket and connectors for any signs of wear, cuts, or damage. Replace the cable if significant damage is observed.

6. Troubleshooting

If you experience issues with signal transmission, consider the following troubleshooting steps:

  • No Signal or Intermittent Signal:
    1. Ensure both ends of the cable are securely and correctly connected to their respective ports.
    2. Check for any visible damage to the cable or connectors (e.g., bent pins, frayed jacket).
    3. Test with a different, known-good cable if available, to rule out the cable as the source of the problem.
    4. Verify that the impedance of the cable (50 Ohm) matches the requirements of your equipment.
  • Incorrect Cable Type or Length:

    If the cable type (e.g., RG316) or length is not suitable for your specific application, it can lead to signal degradation. BEVOTOP offers customization services for various cable types (RG174, RG58, etc.) and lengths (from 10cm to 10M or more) as well as different connector types (SMA, Fakra, TS9, CRC9, etc.).

    Custom-Made Service for Connectors and Cables
    Figure 7: BEVOTOP offers custom-made services for connectors and cables.

7. User Tips

  • Customization: If your application requires a specific cable type (e.g., RG174, RG58, RG142, LMR195, LMR400) or a non-standard length, BEVOTOP can provide custom-made solutions. This also applies to different connector types beyond MCX and FFA 00S.
  • Length Matters: Always choose the shortest practical cable length for your setup to minimize signal loss and ensure optimal performance, especially in high-frequency applications.
  • Compatibility Check: Before purchasing or connecting, double-check the compatibility of the connectors and cable impedance with your existing equipment to avoid issues.

8. Support Information

BEVOTOP specializes in providing a comprehensive range of RF coaxial connectors and cable assemblies. Our products are utilized across various industries including data storage, networking, communications, automotive, medical, and aerospace.

For technical assistance, custom orders, or any inquiries regarding your BEVOTOP product, please refer to the contact information provided by your retailer or visit the official BEVOTOP website.

BEVOTOP RF Coaxial Connectors and Cable Assemblies
Figure 8: BEVOTOP's range of RF coaxial connectors and cable assemblies.
BEVOTOP Manufacturing and Testing Facilities
Figure 9: BEVOTOP's commitment to quality through manufacturing and testing.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.