ZEEWEII DSO3D12

Contents

ZEEWEII DSO3D12 3-in-1 Digital Oscilloscope User Manual

Model: DSO3D12 | Brand: ZEEWEII

Introduction

The ZEEWEII DSO3D12 is a versatile and portable 3-in-1 device that integrates a digital oscilloscope, a high-accuracy true RMS multimeter, and a signal generator. Designed for a wide range of applications from basic R&D and education to car maintenance and DIY debugging, this instrument offers excellent performance and ease of use. Its compact design and comprehensive features make it an ideal tool for electronics enthusiasts and professionals alike.

ZEEWEII DSO3D12 3-in-1 Digital Oscilloscope

Figure 1: ZEEWEII DSO3D12 3-in-1 Digital Oscilloscope

Safety Information

Always observe the following safety precautions to prevent injury and avoid damage to the instrument:

  • Ensure proper isolation: The device features an isolation transformer and isolation optocoupler chip to separate the multimeter from the oscilloscope. This design helps prevent common ground issues. However, when measuring high voltage, the multimeter and oscilloscope functions cannot be used simultaneously.
  • Do not exceed maximum input ratings for any function.
  • Inspect probes and cables for damage before each use.
  • Operate the device in a dry environment, away from moisture and extreme temperatures.
  • Refer to the detailed specifications for voltage and current limits.
Safe design with anti-burn and isolation features

Figure 2: Safe design with anti-burn and isolation features

Getting Started

Package Contents

Verify that all items are present in your package:

  • 1 x ZEEWEII DSO3D12 3-in-1 Digital Oscilloscope
  • 1 x Pair of Test Pens (for Multimeter)
  • 2 x Cables (likely oscilloscope probes)
  • 1 x Charging Cable (TYPE-C)
  • 1 x Set of Accessories (e.g., probe tips, adjustment tool)
Package contents and device dimensions

Figure 3: Package contents and device dimensions (145mm x 86mm x 32mm)

Charging the Device

The DSO3D12 is powered by a built-in 2500mAh rechargeable lithium battery. Use the provided TYPE-C charging cable and a 5V power source to charge the device. A full charge typically takes approximately 6 hours.

Initial Power-On and Language Selection

Press the power button to turn on the device. Upon first use, you may be prompted to select your preferred language (Chinese/English). Navigate using the device's buttons to make your selection.

Operating Instructions

General Interface and Navigation

The device features a 3.2-inch HD IPS color display for clear viewing and soft silicone keys for operation. The main screen provides access to the Oscilloscope, Multimeter (DMM), Signal Generator (GEN), and View functions.

Smart desktop oscilloscope interface

Figure 4: Smart desktop oscilloscope interface

Oscilloscope Function

The oscilloscope features dual channels (CH1 and CH2) with a real-time sampling rate of 250MSa/s. The bandwidth is 120MHz for single channel (CH1 only) and 60MHz for dual channel mode.

  • Automatic Modes: The device supports both one-key automatic and fully-automatic modes. In fully-automatic mode, the device continuously adjusts settings without manual input.
  • Sensitivity and Time Base: Manually adjust vertical sensitivity (voltage per division) using mV and V buttons, and time base (time per division) using S and NS buttons.
  • Trigger Function: Supports Auto, Normal, and Single trigger modes. Trigger types include rise and fall edges. Trigger level can be set manually or automatically, with source options for CH1 or CH2.
  • Dual Channel Operation: When channel 2 is enabled, the device can display two signal waveforms simultaneously for comparative analysis, such as phase difference or complementary PWM dead time.
  • XY Mode: Used to observe Lissajous figures, which represent the phase and frequency relationship between two signals.
  • Persistence: Allows for displaying previous waveforms along with the current one, with options for none, 1 second, or infinite persistence.
  • FFT Spectrum: Performs Fast Fourier Transform to convert time-domain waveforms into the frequency domain for spectrum analysis. Supports linear and logarithmic displays. Note: FFT displays spectrograms but does not support direct frequency measurement.
  • Reference Waveform: Latch a current waveform as a static reference while dynamic waveforms continue to update, useful for comparison.
  • Waveform Save/View: Save screen waveforms with one click. Browse saved images in full-screen mode and delete unwanted charts.
  • Measurement Items: The oscilloscope can measure 14 types of parameters including Frequency, Peak-to-Peak, Duty Cycle, Amplitude, RMS, Average, Period, +Pulse Width, -Pulse Width, Max, Min, Top, Base, and -Duty Cycle.
Dual channel display

Figure 5: Dual Channel Display

XY Mode displaying Lissajous figures

Figure 6: XY Mode Display

FFT Spectrum analysis

Figure 7: FFT Spectrum Analysis

Cursor measurement in oscilloscope mode

Figure 8: Cursor Measurement

Watch this video for a demonstration of various oscilloscope functions:

Video 1: Oscilloscope and Multimeter Function Demonstration

Multimeter Function

The built-in multimeter is a true RMS device, supporting quick software calibration. It can measure DC/AC voltage, DC/AC current, resistance, capacitance, diode, and continuity. The multimeter can be used simultaneously with the oscilloscope (displaying in a small window in the upper right corner) when measuring low voltage, resistance, or continuity.

High-precision multimeter display

Figure 9: High-precision Multimeter Display

Signal Generator Function

The integrated waveform signal generator can output sine, square, and triangle waves. The voltage amplitude is fixed at 2.5V. The frequency is adjustable from 0-2MHz, and the square wave duty cycle can be adjusted from 1% to 99%.

Signal generator output display

Figure 10: Signal Generator Output

Maintenance

To ensure the longevity and optimal performance of your DSO3D12, follow these maintenance guidelines:

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Battery Care: For prolonged storage, charge the battery to approximately 50% every few months to maintain battery health.
  • Probe Care: Handle probes carefully. Avoid bending or stressing the cables. Clean probe tips as needed.

Troubleshooting

If you encounter issues with your DSO3D12, refer to the following common problems and solutions:

  • Device does not power on: Ensure the battery is sufficiently charged. Connect the charging cable and allow it to charge for some time before attempting to power on again.
  • No waveform displayed on oscilloscope:
    • Check probe connections to the device and the circuit under test.
    • Verify that the input signal is within the device's voltage limits.
    • Try using the "One-key Auto" or "Fully Auto" mode to automatically adjust settings.
    • Adjust the vertical sensitivity (mV/V) and time base (S/NS) settings manually.
    • Ensure the trigger settings are appropriate for the signal being measured.
  • Multimeter readings are inaccurate:
    • Ensure test leads are correctly inserted into the appropriate jacks (e.g., VΩmA, COM).
    • Check the battery level, as low battery can affect accuracy.
    • Perform a software calibration if available (refer to the full user guide).
  • Signal generator not producing output:
    • Verify the output cable is correctly connected.
    • Check the frequency and duty cycle settings.
    • Ensure the signal generator function is enabled.

User Tips

Here are some tips from other users to enhance your experience with the DSO3D12:

  • The multimeter function is indeed True RMS, providing accurate measurements for non-sinusoidal waveforms.
  • Utilize the "One-key Auto" feature frequently for quick setup and waveform acquisition, especially when dealing with unknown signals.
  • When comparing two signals, the dual-channel and XY mode features are particularly useful for visualizing phase relationships.
  • Remember the isolation feature: avoid using the oscilloscope and multimeter simultaneously when working with high voltages to prevent potential damage or inaccurate readings.

Specifications

General Specifications

FeatureValue
ModelDSO3D12
Screen Size3.2 inches IPS color screen
LanguageChinese/English
KeysSoft silicone keys
ChargingTYPE-C 5V
BatteryBuilt-in 2500mAh rechargeable lithium battery
Battery TimeAbout 6 hours
Case Size145 * 86 * 32mm
WeightApprox. 0.7 kg (1.32 lb package weight)
CertificationCE
DIY SuppliesElectrical

Oscilloscope Parameters

ParameterValue
Channels2
Real-time Sample Rate250MSa/s
Analog Bandwidth120MHz (CH1 Only); 60MHz (CH1+CH2)
Equivalent Sampling500M
Rise Time<3ns
Storage Depth128Kb
Impedance1MΩ
Time Base Range5ns - 10s
Peak Voltage±40V (1x), ±400V (10x)
Trigger ModeAuto/Normal/Single
Trigger TypeRise/Fall
Display ModeYT / XY / Roll
PersistenceNone / 1s / ∞
Auto ModeOneKey-Auto / Fully-Auto
Sensitivity (X1)10mV/div ~ 10V/div
Sensitivity (X10)100mV/div ~ 100V/div
Measurement Items14 types
DC Offset±2%
XY ModeYes
ScreenshotYes
Frequency Accuracy±0.01%
Zoom ModeYes
FFTYes

Multimeter Parameters

FunctionRangePrecision
DC Voltage600mV/6.00V/60.0V/600V/750V±(0.5%+3)
AC Voltage600mV/6.00V/60.0V/600V±(1%+3)
DC Current600mA/10A±(2%+5)
AC Current600mA/10A±(3%+5)
Resistance600.0Ω±(1.5%+3)
6.000kΩ/60.00kΩ/600.0kΩ±(1%+3)
6.000MΩ±(1.5%+5)
60.00MΩ±(3%+3)
Capacitance60.00nF/600.0nF/6.000μF±(5%+5)
60.00μF/600.0μF±(10%+5)
Diode0.0V~3.3V (3.3V higher displays OL)
ContinuitySound at 50Ω and below

Note on Current Measurement: The 600mA hole has a 1A fuse, while the 10A hole does not have a fuse.

Signal Generator Parameters

ParameterValue
WaveformsSine, Square, Triangular
Voltage Amplitude2.5V ±0.05V
Frequency Range1Hz - 2MHz
Square Wave Duty Cycle1% - 99% (Adjustable)

Warranty and Support

For detailed warranty information, technical support, and the most up-to-date user guide, please refer to the official product manual available online:

Official User Guide (PDF): DSO3D12 User Guide EN.pdf

This manual provides comprehensive details on advanced features, calibration procedures, and specific troubleshooting steps not covered in this summary.