1. Introduction
The ZEEWEII DSO3D12 is a versatile 3-in-1 desktop digital instrument combining the functionalities of a digital oscilloscope, a high-precision true RMS multimeter, and a 2.5V signal generator. Designed for a wide range of applications including single-chip debugging, car maintenance, home appliance repair, DIY projects, electronic competitions, and power supply debugging, this device offers excellent performance and ease of use. It adopts ARM and FPGA chip collocation for high-speed signal acquisition and data processing.
2. Key Features
- Oscilloscope: 120M bandwidth (60M in dual channel mode), 250MSa/s real-time sampling rate, 500M equivalent sampling rate.
- Multimeter: High-precision true RMS measurements for voltage, current, resistance, diode, continuity, and capacitance. Features isolation from the oscilloscope for safety.
- Signal Generator: Outputs sine, square, triangle, half-wave, and 'singh' waves with 2.5V amplitude and adjustable frequency from 0-2MHz.
- Display: 3.2-inch high-definition IPS display for clear and delicate waveform visualization.
- Measurement Options: 14 types of automatic measurements including Frequency, Peak-to-Peak, Duty cycle, Amplitude, RMS, Average, Period, +Pulse width, -Pulse width, Max, Min, Top, Base, and -Duty cycle.
- Modes: Supports XY mode, FFT (Fast Fourier Transform) for frequency domain analysis, Roll mode, Single trigger, and Persistence (None/1s/∞).
- Automation: Fully automatic and one-key auto measurement modes for quick waveform adjustment.
- Safety: Safe design with isolation transformer and optocoupler chip to isolate the multimeter, preventing common ground issues when measuring high voltage.
- Waveform Management: Waveform Save/View function allows saving screen waveforms and browsing them in full-screen, with options to delete unwanted charts.
3. Package Contents
The DSO3D12 package includes the following items:
- DSO3D12 3-in-1 Digital Oscilloscope Unit
- Oscilloscope Probes (2x)
- Multimeter Test Leads (Red and Black)
- USB Type-C Cable
- Small screwdriver for probe adjustment
- Color rings for probe identification

4. Setup
- Power On/Off: Press and hold the power button located on the side of the device to turn it on or off.
- Charging: Connect the device using the provided USB Type-C cable to a 5V power source for charging. The battery provides approximately 6 hours of operation.
- Oscilloscope Probe Connection: Connect the oscilloscope probes to the BNC connectors labeled CH1 and CH2 on the top of the device. Ensure a secure connection.
- Multimeter Test Lead Connection: Connect the multimeter test leads to the input jacks at the bottom of the device. Use the 10A jack for high current measurements (unfused), the 600mA FUSED jack for lower current measurements, and the COM and VΩ jacks for voltage, resistance, diode, continuity, and capacitance measurements.
- Signal Generator Output: The signal generator output is available from the device's bottom.
5. Operating Instructions
5.1 General Operation
The DSO3D12 features a user-friendly interface with soft silicone keys for navigation and function selection.

- One-Key Auto: Click the 'Auto' button to automatically detect and display waveforms, simplifying setup for beginners.
- Navigation: Use the directional buttons (up, down, left, right) and 'OK' button to navigate menus and adjust settings.
- Shift: The 'Shift' button provides access to secondary functions of the keys.
5.2 Oscilloscope Functions
The oscilloscope mode allows for detailed analysis of electrical signals.
- Time Base & Vertical Sensitivity: Adjust these parameters using the dedicated buttons or menu options to scale the waveform display appropriately.
- Roll Mode: Allows continuous scrolling of the waveform across the screen, useful for observing slow-changing signals.
- Single Trigger: Captures a single waveform event when the trigger condition is met, ideal for non-repeating signals.
- Dual Channel: When channel 2 is turned on, the device operates in dual-channel mode, allowing simultaneous measurement and display of two signal waveforms for comparative analysis (e.g., phase difference, dead time of complementary PWM).

Figure 5.2: Dual channel mode displaying two waveforms (CH1 and CH2). - XY Mode: Combines the waveforms of two channels to form an image, primarily used to observe Lissajous figures.

Figure 5.3: Examples of Lissajous figures in XY Mode. - Persistence: Allows waveforms to remain on the screen for a set duration (None, 1s, or infinite), useful for observing signal variations over time.
- FFT (Fast Fourier Transform): Converts waveforms from the time domain to the frequency domain, enabling analysis of frequency components. Supports linear and logarithmic display. Note: FFT displays spectrograms; frequency measurement is not supported.

Figure 5.4: FFT spectrum analysis of a waveform. - Zoom: Allows magnifying specific sections of the waveform for detailed inspection.
- Waveform Save/View: Save screen waveforms with one click. Enter the picture browsing page to view thumbnails in full-screen or delete unwanted waveform charts.

Figure 5.5: Waveform Save/View interface. - Cursor Measurement: Supports X and Y cursor measurements. Horizontal cursors measure time intervals between pulses, while vertical cursors measure voltage and voltage differences at any two locations.

Figure 5.6: Cursor measurement in action. - Trigger Settings: Configure trigger type (Rise/Fall), trigger level (Manual/Auto), and trigger source (CH1/CH2) for stable waveform acquisition.

Figure 5.7: Trigger settings interface.
5.3 Multimeter Functions
The built-in multimeter provides accurate measurements for various electrical parameters. It supports fast software calibration.
- Voltage Measurement: Measure DC and AC voltages.
- Current Measurement: Measure DC and AC currents. Note: The 600mA hole has a 1A fuse, while the 10A hole is unfused.
- Resistance Measurement: Measure resistance values.
- Diode Test: Test diodes for forward voltage drop.
- Continuity Test: Check for circuit continuity with an audible sound at 50Ω and below.
- Capacitance Measurement: Measure capacitance values.

5.4 Signal Generator Functions
The integrated signal generator can output various waveforms for testing and debugging.
- Waveform Types: Generate sine wave, square wave, triangle wave, half wave, and 'singh' wave.
- Voltage Amplitude: Fixed at 2.5V.
- Frequency Adjustment: Adjustable from 0-2MHz.
- Duty Cycle: For square waves, the duty cycle is adjustable from 1% to 99%.

6. Specifications
6.1 Oscilloscope Parameters
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Model | DSO3D12 | Key type | Soft silicone keys |
| Screen size | 3.2 inch | Charging | TYPE-C 5V |
| Language | 中文/English | Battery time | about 6 hours |
| Bracket | Collapsible stand | Case size | 14.5*8.6*3.2cm |
| Channels | 2 | Coupling | AC/DC |
| Real time sample rate | 250MSa/s | Auto mode | oneKey-auto/fully-auto |
| Bandwidth | 120MHz (CH1 Only) / 60MHz (CH1+CH2) | Sensitivity | X1:10mV/div~10V/div, X10:100mV/div~100V/div |
| Equivalent sampling | 500M | Measure items | 14 types |
| Rise time | <3ns | DC Offset | ±2% |
| Storage | 128Kb | XY mode | yes |
| Impedance | 1MΩ | Screenshot | yes |
| TimeBase | 5ns - 10s | Frequency | ±0.01% |
| Peak voltage | ±40V (1x), ±400V (10x) | Zoom mode | yes |
| Trigger mode | auto/normal/single | FFT | yes |
| Trigger type | rise/fall | Generator wave | sin/square/triangular... |
| Display mode | YT/XY/Roll | Generator Vol | 2.5V±0.05 |
| Persistence | none/1s /∞ | Generator freq | 1Hz~2MHz |
6.2 Multimeter Parameters
| Function | Range | Precision |
|---|---|---|
| DC voltage | 600mV/6.00V/60.0V/600V/750V | ±(0.5%+3) |
| AC voltage | 600mV/6.00V/60.0V/600V | ±(1%+3) |
| DC current | 600mA / 10A | ±(2%+5) |
| AC current | 600mA / 10A | ±(3%+5) |
| Current note: 600mA hole with 1A fuse, 10A hole without fuse | ||
| Resistance | 600.0Ω | ±(1.5%+3) |
| 6.000kΩ/60.00kΩ/600.0kΩ | ±(1%+3) | |
| 6.000MΩ | ±(1.5%+5) | |
| 60.00MΩ | ±(3%+3) | |
| Capacitance | 60.00nF/600.0nF/6.000μF | ±(5%+5) |
| 60.00μF/600.0μF | ±(10%+5) | |
| Diode | 0.0V~3.3V, 3.3V higher display OL | |
| Continuity | Sound at 50Ω and below | |
7. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- Battery Care: For optimal battery life, avoid fully discharging the battery frequently. Charge the device regularly, especially if it will be stored for an extended period.
- Probe Care: Handle probes carefully. Avoid bending or stressing the cables excessively. Replace damaged probes immediately.
8. Troubleshooting
- No Display/Power: Ensure the device is charged or connected to a power source. Check the power button.
- No Waveform Display: Verify probe connections. Check trigger settings (level, source, type). Use the 'Auto' button to attempt automatic waveform detection. Ensure the input signal is within the device's voltage range.
- Incorrect Multimeter Readings: Check test lead connections. Ensure the correct function (voltage, current, resistance, etc.) is selected. For current measurements, ensure the leads are in the correct current jacks (600mA or 10A).
- Signal Generator Not Outputting: Verify the signal generator is enabled and configured with desired waveform, frequency, and duty cycle. Check the output connection.
- Device Unresponsive: Try restarting the device. If issues persist, refer to the full user manual for more detailed troubleshooting steps.
9. Warranty and Support
For detailed warranty information, technical support, and a comprehensive user guide, please refer to the official ZEEWEII documentation. A full user manual in English (PDF format) can be downloaded from the following link:
DSO3D12 User Guide (English PDF)
Please ensure you have the latest version of the user manual for the most up-to-date information.