TENSTAR ROBOT 6-30V Relay Module Switch User Manual

Model: HW-521

1. Product Overview

The TENSTAR ROBOT HW-521 is a versatile 6-30V relay module switch designed for various timing and control applications. It features a digital display for time settings, multiple operating modes, and optocoupler isolation for enhanced anti-interference capabilities. This module is suitable for controlling DC loads up to 30V 5A or AC loads up to 220V 5A.

Key Features:

  • Operating Voltage: 6-30V DC
  • Trigger Signal Source: High Level Trigger (3.0V-24V DC)
  • Output Capacity: Max 30V DC 5A or 220V AC 5A
  • Optocoupler Isolation: Improves anti-interference ability
  • Parameter Memory: Settings are saved permanently
  • Display: Digital display for time and mode indication
  • Power Input: Terminal block or Micro USB 5V
TENSTAR ROBOT HW-521 Relay Module Front View

Front view of the HW-521 Relay Module, showing the digital display, relay, and control buttons.

TENSTAR ROBOT HW-521 Relay Module Size Reference

The HW-521 Relay Module held in hand, illustrating its compact size.

2. Setup and Wiring

Before connecting the module, ensure all power sources are disconnected. The module can be powered via the terminal block (6-30V) or a Micro USB 5V port. The relay contact is passive, meaning it does not supply power to the controlled device; it acts as a switch.

Component Identification:

HW-521 Relay Module Component Labels

Diagram showing the main components and controls: Emergency Stop Key (STOP), Setting Key (SET), UP Key, DOWN Key, Micro USB 5.0V Power Supply, Transposition Protection, and relay terminals (NO, COM, NC).

Wiring Diagrams:

The module offers flexible wiring options depending on your application. Always ensure correct polarity and voltage levels.

Common Power Connection Diagram

Common Power Connection Picture: This diagram illustrates how to connect the module and the load using a single power source (6.0-30V). The trigger signal (3-24V) is separate. Input + and - are for module power. The load connects to the relay terminals (NO/NC and COM).

Low Voltage Control High Voltage Connection Diagram

Low Voltage Control High Voltage Connection Picture: This diagram shows how to use the module to control a high voltage (e.g., 220VAC) device using a low voltage input (6.0-30V) for the module itself. The high voltage device is connected to the relay's COM and NO/NC terminals, while the module is powered separately.

HW-521 Relay Module Back View Pinout

Back view of the module, showing pin labels for GND, +5V, 6.0-30.0V, Trigger, GND_T, NO, COM, and NC.

3. Operating Modes

The module supports several operating modes, each designed for different timing control scenarios. The cycle times (LOP) can be set from 1 to 999 times, or '---' for unlimited cycles.

  • P1: Triggered ON, then OFF
    After receiving a trigger signal, the relay turns ON for a set 'OP' time, then turns OFF.
    • P1.1: Signal re-trigger is ineffective during the OP period.
    • P1.2: Signal re-trigger restarts the OP timer.
    • P1.3: Signal re-trigger resets the module, disconnects the relay, and stops timing.
  • P2: Triggered OFF, then ON, then OFF
    Upon receiving a trigger signal, the relay turns OFF for a set 'CL' time, then turns ON for a set 'OP' time, then turns OFF.
  • P3.1: Triggered Cycle (Limited/Unlimited)
    After receiving a trigger signal, the relay cycles ON for 'OP' time and OFF for 'CL' time. This cycle repeats for 'LOP' times. A new trigger signal during the cycle will stop the timing and disconnect the relay.
  • P3.2: Auto Cycle (Limited/Unlimited)
    After connecting power (no trigger signal needed), the relay immediately starts cycling ON for 'OP' time and OFF for 'CL' time. This cycle repeats for 'LOP' times.
  • Q4: Signal-Keeping Function
    The relay remains connected as long as the trigger signal is present. When the signal disappears, the 'OP' timer starts, and after 'OP' time, the relay turns OFF. If the signal reappears before 'OP' time expires, the timer is cleared, and the relay stays connected.

4. Parameter Setting

Configuring the module's parameters involves selecting the operating mode and then setting the specific time values (OP, CL) and cycle count (LOP).

Time Interval Selection:

The time interval (0.1 seconds to 999 minutes) is determined by the position of the decimal point on the display. To change the time interval, press the STOP button in the parameter setting interface:

  • xxx. (Decimal point in the hundreds place): Time interval is 1 second to 999 seconds.
  • xx.x (Decimal point in the tens place): Time interval is 0.1 seconds to 99.9 seconds.
  • x.x.x (All decimal points on): Time interval is 1 minute to 999 minutes.

Setting Procedure:

  1. Determine Operation Mode: First, decide which operating mode (P1.1 to Q4) best suits your application.
  2. Enter Mode Selection: From the main interface (which shows "000" when idle, or a decimal point when operating), long press the SET key for two seconds to enter the mode selection interface.
  3. Select Mode: Use the UP and DOWN keys to navigate and choose the desired operating mode (P1.1 ~ Q4).
  4. Set Parameters: After selecting the mode, short press the SET key. The first parameter (e.g., OP time) will flash.
  5. Adjust Parameter Value: Use the UP and DOWN keys to adjust the flashing parameter's value. A long press will increase/decrease quickly, while a short press changes by 1 unit.
  6. Select Time Interval: While a parameter is flashing, short press the STOP key to cycle through the decimal point positions, thereby selecting the desired time interval (seconds or minutes).
  7. Move to Next Parameter: After setting the current parameter's value and time interval, short press the SET key to move to the next parameter (e.g., CL time, then LOP cycle times). Repeat steps 5 and 6 for each parameter.
  8. Save Settings: Once all parameters for the chosen mode are set, long press the SET button. The current configuration mode will flash briefly, and the module will return to the main interface, indicating successful parameter definition.

5. Expansion Functions (STOP Key)

The STOP key provides additional control functionalities beyond parameter setting.

Activate Relay Mode:

This function allows you to quickly enable or disable the relay's operation.

  • NO (Normal Open): When the module is powered and in an active timing state, the relay can be connected according to the programmed logic.
  • OFF (Disabled): The relay is not allowed to connect, effectively turning off its switching function.

To toggle between ON and OFF states, short press the STOP key from the main interface. The current state will flash briefly, then return to the main interface. This acts as an emergency stop or quick disable function.

Sleep Mode:

The module offers two display modes to manage power consumption and visibility.

  • C-P Sleep Mode: If there is no operation for 5 minutes, the digital display (nixie tube) will automatically turn off to save power. The programmed function will continue to run in the background.
  • d-Normal Mode: The digital display remains continuously on.

To switch between C-P Sleep Mode and d-Normal Mode, long press the STOP button for 2 seconds. The current state will flash, and then the module will return to the main interface with the new display mode active.

6. Specifications

FeatureSpecification
Operating Voltage6-30V DC
Trigger Signal SourceHigh Level Trigger (3.0V-24V DC)
Output CapacityDC 30V 5A or AC 220V 5A
Time Interval Range0.1 seconds to 999 minutes (continuously adjustable)
Optocoupler IsolationYes
Parameter MemoryPermanent after setting
Dimensions (L x W x H)6.3 x 3.8 x 1.5 cm (2.48" x 1.50" x 0.59")
ApplicationComputer, General Electronic Control
ConditionNew

7. User Tips

  • Read Instructions Carefully: Several users have noted that the setup and operating instructions can be complex. Take your time to understand each mode and parameter setting step.
  • Power Supply Considerations: When operating the module at higher voltages (e.g., 24V), monitor the temperature of the voltage regulator. If it becomes excessively hot, consider adding a heatsink or ensuring adequate ventilation to prevent damage.
  • Check Physical Condition: Upon receiving the module, inspect it for any physical damage, such as bent pins, which can occur during transit.
  • Test Thoroughly: Before integrating the module into a critical project, test all desired operating modes and parameter settings to ensure it functions as expected.

8. Troubleshooting

  • Module Not Powering On:
    Ensure the operating voltage is within 6-30V DC and correctly connected to the terminal block, or that a stable 5V DC supply is connected via the Micro USB port. Check for correct polarity.
  • Relay Not Activating/Deactivating:
    Verify the trigger signal source is providing a high-level trigger (3.0V-24V). Check the selected operating mode and ensure parameters (OP, CL, LOP) are set correctly. Ensure the relay is not in 'OFF' activate relay mode (check with short press of STOP key).
  • Module Gets Hot:
    If the module becomes excessively hot, especially when using higher input voltages (e.g., 24V), ensure the load current does not exceed 5A. Consider adding a heatsink to the voltage regulator or improving ventilation.
  • Parameters Not Saving:
    After setting parameters for a mode, ensure you perform a long press of the SET button to save the configuration and return to the main interface.
  • Display Issues:
    If the display is off, check if the module is in 'C-P Sleep Mode'. Long press the STOP button for 2 seconds to switch to 'd-Normal Mode'.
  • Unexpected Behavior:
    Double-check all wiring connections against the provided diagrams. Review the selected operating mode and its specific logic. Incorrect wiring or parameter settings are common causes of unexpected operation.

9. Warranty and Support

This product is manufactured by TENSTAR ROBOT. For technical support or warranty inquiries, please contact your retailer or refer to the seller's support channels. Keep your purchase receipt for warranty claims.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.