1. Introduction

The Scimagic-RC RTU5024 GSM Gate Opener is a powerful and versatile GSM relay designed for authorized door access, gate control, remote equipment switching, and car parking systems. It allows you to remotely turn ON/OFF systems, machines, or equipment with a free call from your mobile phone, providing a convenient and secure access solution.

This manual covers both the RTU5024 and RTU5035 models, highlighting their specific features and specifications where they differ.

RTU5024 GSM Gate Opener, front view with antenna
Figure 1: RTU5024 GSM Gate Opener

2. Product Features

2.1 Common Features (RTU5024 & RTU5035)

  • No Call Charges: The device rejects calls from authorized numbers and performs the ON/OFF action on the first 'ring', eliminating call costs.
  • Remote Operation: Can be operated from anywhere with no distance limit.
  • Secure Access: Uses caller ID for identification, ignoring unknown callers.
  • Multiple Applications: Suitable for gates, bollards, barriers, garage doors, shutters, access doors, and various machines.
  • SMS User Management: Users can be added or removed via SMS text commands.
  • No Remote Control Needed: Eliminates the need for physical remote controls or keys for different users.
  • Relay Output: Features a relay output for connecting to the switch of a door or machine.
  • SMS Confirmation: The relay action can return an SMS confirmation to the owner or authorized number (user-editable).

2.2 RTU5024 Specific Features

  • Authorized Users: Supports up to 200 authorized phone numbers.
  • Relay Output Rating: 3A/240VAC.
  • Programmable Relay Time: The relay close or open time is programmable.
  • Quad-band GSM: Works in worldwide GSM Networks (850/900/1800/1900MHz).

2.3 RTU5035 Specific Features

  • Authorized Users: Supports up to 999 authorized phone numbers.
  • Relay Output Rating: 6A/240VAC.
  • Innovative Door Opening: Can open the door by shaking the mobile phone (feature).
  • Digital Inputs: Two digital inputs for connecting door sensors, motion sensors, or other sensors. When triggered, sends SMS alert and activates a siren.
  • Wired Probes: Supports adding 2 wired probes to edit alarm information and connect to door magnetic smoke alarms.
  • GSM Frequency: 900/1800MHz.
RTU5024 in use, showing a smartphone making a free call to open a garage door
Figure 2: Remote control via free call
Multiple applications for the GSM Gate Opener, including gates, barriers, and garage doors
Figure 3: Multiple application scenarios
Illustration of time-limited access control and SMS notification for door operations
Figure 4: Time-limited access and SMS notifications

3. Specifications

3.1 RTU5024 Specifications

AttributeValue
GSM FrequencyQuad-band 850/900/1800/1900MHz
Digital OutputNC/NO dry contact, 3A/240VAC
DC Power Supply9-24VDC/2A
Power Consumption12V Input Max.50mA/Average 25mA
SIM CardSupport 3V SIM Card
Antenna Interface50Ω SMA
Temperature Range-20℃~+60℃
Humidity RangeRelative Humidity 90%
Exterior DimensionW82mm*D76mm*H27mm
Dimensions of the RTU5024 device
Figure 5: RTU5024 Dimensions

3.2 RTU5035 Specifications

AttributeValue
Rated Voltage12VDC 1A
Working Temperature-10℃~+60℃
-10℃~+60℃-20℃~+60℃
Relative Humidity10-90%, No condensation
Work Frequency900/1800MHz
Communication ProtocolGSM PHASE 2/2+ (include data service)
Wired Zones2
Signal2G/3G/4G
Output Relay Voltage6A/240V AC
Dimensions of the RTU5035 device
Figure 6: RTU5035 Dimensions

4. Package Contents

4.1 RTU5024 Package

  • 1 x RTU5024 GSM Gate Opener
  • 1 x Good Gain Antenna

4.2 RTU5035 Package

  • 1 x RTU5035 GSM Gate Opener
  • 1 x Good Gain Antenna
  • 1 x Card Pin
RTU5035 package contents, including the device, antenna, and SIM card adapters
Figure 7: RTU5035 Package Contents (includes SIM card pin)

5. Setup and Installation

5.1 SIM Card Installation

Before powering on the device, install a 3V SIM card into the designated slot. Ensure the SIM card is active and has sufficient credit for SMS commands if needed.

Diagram showing the installation of a SIM card into the RTU5024 device
Figure 8: SIM Card Installation

5.2 Antenna Connection

Connect the provided Good Gain Antenna to the SMA antenna interface on the device. Ensure it is securely fastened for optimal signal reception.

5.3 Power Supply

Connect the device to a compatible DC power supply. For RTU5024, use 9-24VDC/2A. For RTU5035, use 12VDC 1A. Ensure the power supply meets the specified voltage and current requirements.

5.4 Wiring Diagrams

The device features relay outputs (NO, COM, NC) for connecting to your gate opener, electric lock, or other equipment. Refer to the diagrams below for typical wiring configurations.

Labeled diagram of the RTU5024 front panel, indicating signal light, relay light, power port, and relay output terminals (NO, COM, NC)
Figure 9: RTU5024 Front Panel Layout
  • 1. Signal light
  • 2. Relay light
  • 3. Power port
  • 4. Normal open (NO)
  • 5. Common (COM)
  • 6. Normal close (NC)
Wiring diagrams for RTU5024, showing connections for a gate opener (electric lock) and a remote switch (motor/pump)
Figure 10: RTU5024 Wiring for Gate Opener and Remote Switch

RTU5024 for Gate Opener: Power up the RTU5024 and the electronic lock using the same DC source. The lock is switched ON/OFF by a phone call.

RTU5024 for Remote Switch: The pump (or other equipment) is switched ON/OFF by a phone call. The pump is powered by the grid/electricity, and the RTU5024 is powered by an AC/DC adaptor.

For RTU5035, additional wired zones (In1, In2) are available for sensors. Refer to the product's specific SMS command manual for detailed setup of these inputs.

Diagram illustrating multiple applications for RTU5035 in a smart home setup (controlling lights, doors, appliances)
Figure 11: RTU5035 Smart Home Integration Example

6. Operation

6.1 Adding/Removing Authorized Users

Authorized phone numbers are managed via SMS commands. Please refer to the latest SMS instruction manual provided with your device for specific commands to add, delete, or modify authorized numbers.

Important: Due to product upgrades, always use the latest SMS instructions in the manual to operate the machine.

6.2 Remote Control via Call

Once authorized numbers are configured, simply dial the phone number of the GSM Gate Opener from an authorized mobile phone. The device will reject the call and activate its relay, opening your gate or switching your equipment ON/OFF.

Video 1: Demonstration of RTU5024 controlling an electric lock via phone call.

6.3 Remote Switching ON/OFF

For applications like turning pumps or lights ON/OFF, the same free call method applies. The relay will toggle its state upon receiving a call from an authorized number.

6.4 Time-Limited Access (RTU5035)

The RTU5035 model allows for time-limited access control. Users can be granted access only during pre-set time periods. Configuration details are available in the specific RTU5035 SMS command manual.

6.5 SMS Alerts and Sensor Integration (RTU5035)

The RTU5035's two digital inputs can be connected to various sensors (e.g., door sensors, motion sensors). When a sensor is triggered, the device can send an SMS alert message to designated numbers and activate a siren. This feature is useful for security and monitoring.

7. User Tips

  • Power Source: Both RTU5024 and RTU5035 are compatible with 12V DC power sources, including 12V batteries, making them suitable for various installations.
  • SIM Card: Always ensure your SIM card is active, has sufficient credit, and supports 2G GSM networks (900/1800MHz for RTU5035, Quad-band for RTU5024).
  • SMS Commands: Keep the physical instruction manual handy for the most up-to-date SMS commands, especially after product upgrades.
  • Signal Strength: Place the device in an area with good GSM signal strength. The external antenna helps, but a weak signal can affect reliability.
  • Testing: After installation and configuration, thoroughly test all functions (opening/closing, SMS alerts) to ensure proper operation.

8. Troubleshooting

8.1 Device Not Responding to Calls

  • Check SIM Card: Ensure the SIM card is correctly inserted, active, and has credit.
  • Authorized Number: Verify that the calling number is correctly registered as an authorized user via SMS commands.
  • GSM Signal: Check the signal light on the device. If it's blinking irregularly or off, there might be a poor GSM signal. Relocate the device or check the antenna connection.
  • Power Supply: Confirm the device is receiving adequate power (9-24VDC for RTU5024, 12VDC for RTU5035).

8.2 Relay Not Activating

  • Wiring: Double-check the wiring connections to the gate opener or equipment. Ensure NO/COM/NC terminals are correctly used.
  • Relay Light: Observe the relay light on the device. If it doesn't illuminate when a call is made, the internal relay might not be triggering.
  • Load Compatibility: Ensure the connected equipment's power requirements do not exceed the relay's rating (3A/240VAC for RTU5024, 6A/240VAC for RTU5035).

8.3 SMS Commands Not Working

  • Correct Format: Ensure SMS commands are sent in the exact format specified in the manual.
  • SIM Card Credit: The SIM card must have sufficient credit to send and receive SMS messages.
  • Network Issues: Temporary network congestion or issues can delay or prevent SMS delivery.

9. Maintenance

  • Keep Clean: Periodically clean the device with a soft, dry cloth. Avoid using harsh chemicals or solvents.
  • Environmental Conditions: Ensure the device is operated within its specified temperature and humidity ranges to prolong its lifespan.
  • Connection Checks: Regularly inspect all wiring and antenna connections for any signs of wear or looseness.
  • Firmware Updates: Check the manufacturer's website for any available firmware updates that might improve performance or add features.
  • SIM Card Management: Monitor SIM card credit and expiry dates to ensure continuous operation.

10. Warranty and Support

This product is covered by a standard manufacturer's warranty against defects in materials and workmanship. For specific warranty terms, duration, and support inquiries, please refer to the documentation provided at the time of purchase or contact your retailer. Keep your proof of purchase for warranty claims.

For technical assistance or further questions, please contact Scimagic-RC Official Store customer support.

11. Important Notes & Compatibility

  • GSM Network Compatibility: The RTU5035 operates on 900/1800MHz GSM frequencies. The RTU5024 is Quad-band (850/900/1800/1900MHz). Ensure your local network supports these frequencies.
  • Regional Restrictions: The RTU5035 is applicable in Europe, Africa, and most Asian countries. It is NOT applicable in Japan, Korea, Australia, Singapore, and New Zealand due to differing network standards.
  • Security: While the device uses caller ID for security, it is recommended to use it in conjunction with other security measures for critical access points.

Scimagic-RC RTU5024 GSM Gate Opener Remote Switch Setup and Operation Guide

Scimagic-RC RTU5024 GSM Gate Opener Remote Switch Setup and Operation Guide

0:45 • 1280×720 • setup
Scimagic-RC RTU5024 GSM Gate Opener Remote Switch Product Demonstration

Scimagic-RC RTU5024 GSM Gate Opener Remote Switch Product Demonstration

0:21 • 960×540 • demonstration