Tewaycell TW-MB48300-100A-APP

Tewaycell 15KWh Powerwall LiFePO4 Battery Pack

Model: TW-MB48300-100A-APP / TW-MB51300-100A-APP

User Instruction Manual

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Tewaycell 15KWh Powerwall LiFePO4 Battery Pack. Please read this manual thoroughly before using the product and retain it for future reference.

Tewaycell 15KWh Powerwall with key features

Figure 1: Tewaycell 15KWh Powerwall highlighting 6000+ cycles, CAN/RS485, Built-in BMS, Mobile Pack, and Bluetooth connectivity.

2. Safety Information

  • Do not immerse the battery in water or allow it to get wet.
  • Do not use or store the battery in extremely hot environments.
  • Avoid using the battery in strong electrostatic and magnetic fields, as this may compromise battery safety.
  • Do not reverse the positive (+) and negative (-) terminals to prevent reverse connection.
  • Charge the battery using the specified charger and according to the charging requirements.
  • Ensure correct connection between the inverter and MPPT. For technical issues, contact Tewaycell support.

California's Proposition 65 Warning: This product contains Lithium carbonate, a chemical known to the State of California to cause developmental toxicity. For more information go to www.P65Warnings.ca.gov.

3. Product Specifications

3.1. Model TW-MB51300-100A-APP (16S)

ParameterValue
Nominal Voltage51.2V (16S)
Nominal Capacity304Ah@0.2C
Battery Power15565Wh
Internal Resistance≤100mΩ
Cycle Life6000+ times
Self Discharge≤3.5% (every month@25°C)
Charging Voltage51.2-58.4V
Charging Cut-off Voltage58.4V
Weight131KG

3.2. Model TW-MB48300-100A-APP (15S)

ParameterValue
Nominal Voltage48.0V (15S)
Nominal Capacity304Ah@0.2C
Battery Power14592Wh
Internal Resistance≤100mΩ
Cycle Life6000+ times
Self Discharge≤3.5% (every month@25°C)
Charging Voltage53.2-54V
Charging Cut-off Voltage54.75V
Weight125KG

3.3. General Parameters

ParameterValue
Standard Discharge Current40A
Maximum Sustained Discharge100A
Maximum Pulse Current120A (<30S)
Standard Charging Current40A
Maximum Continuous Charging Current100A
Maximum Discharge Power5000W
Charging Temperature0°C to 45°C
Discharge Temperature-20°C to 60°C
Dustproof and Waterproof RatingIP55
Shell MaterialSPCC
Size (L x W x H)520 x 300 x 900mm
Fire ExtinguisherBuilt-in
Active BalanceBuilt-in
Communication PortsRS485*3 / CAN / RS232
Battery Discharge Curves

Figure 2: Battery discharge curves at different rates and temperatures.

Battery Test Curve Analysis

Figure 3: Open circuit voltage vs SOC% and battery test curve analysis details.

4. Setup Instructions

4.1. Unpacking and Inspection

Carefully unpack the battery pack. Verify that all components listed below are present and undamaged:

  • Tewaycell Powerwall Battery Pack
  • Fit screws
  • Parallel Power Cable
  • Inverter Cable for RS485/CAN/RS232
Packing List and Battery Appearance

Figure 4: Contents of the packing list and the appearance of the battery pack.

4.2. Physical Installation

The battery pack is designed for household energy storage. Its dimensions are 520mm (L) x 300mm (W) x 900mm (H). It is equipped with handles and wheels for easier movement and positioning. Ensure the installation location is dry, well-ventilated, and within the specified operating temperature range.

Powerwall Dimensions

Figure 5: Detailed dimensions of the Tewaycell Powerwall.

4.3. Electrical Connections

Refer to the diagrams below for proper electrical connections. The battery features positive (+) and negative (-) terminals, communication ports (RS485*3, CAN, RS232), and an Air Switch for safety.

Detailed view of Powerwall top panel and indicators

Figure 6: Top panel details showing terminals, power switch, indicators, and communication ports.

Air Switch and Active Balance

Figure 7: Location of the Air Switch and Active Balance feature.

4.3.1. System Integration Diagram

Schematic Diagram of Powerwall Connection

Figure 8: General schematic for powerwall connection with solar panels, utility grid, generator, inverter, and home loads.

Energy Storage Battery System Diagram

Figure 9: Energy storage battery system diagram showing connections to various power sources and home appliances.

4.3.2. Inverter Compatibility

The Tewaycell Powerwall is compatible with various inverter brands. Ensure your inverter supports CAN, RS485, or RS232 communication protocols. Known compatible brands include:

  • Victron Energy
  • Pylontech
  • Deye
  • SMA
  • Growatt
  • Goodwe
  • Voltronic Power
  • MPP Solar
  • Sofarsolar
  • Megarevo
  • Tbbpower
  • Schneider Electric
  • Arun Technology
  • Solax Power
  • LTW
  • SZPC
  • Bakee
  • MUST
  • LUXPOWER
  • SRNE Solar

If your inverter brand is not listed, please contact Tewaycell support to confirm compatibility.

Compatible Inverter Brands

Figure 10: Logos of various communication inverter brands compatible with the Tewaycell Powerwall.

4.3.3. Parallel Connections

The Tewaycell Powerwall supports up to 16 units connected in parallel to increase total energy storage capacity. When connecting multiple units, ensure proper wiring and use the provided parallel power cables. For high current discharge configurations, an appropriate Air Switch is required.

Supports up to 16 parallel connections

Figure 11: Illustration of multiple powerwalls connected in parallel for increased capacity.

High Current Discharge Wiring Diagram

Figure 12: Wiring diagram for high current discharge with multiple batteries and an Air Switch.

5. Operating Instructions

5.1. Initial Power-Up

After all electrical connections are securely made, turn on the main power switch on the battery pack. Observe the ON/OFF indicator, SOC indicator, and Running indicator for normal operation. The Alarm indicator will light up if an issue is detected.

5.2. Bluetooth and Mobile APP

The Tewaycell Powerwall features Bluetooth connectivity for monitoring and control via a mobile application. The APP allows you to monitor battery power, adjust communication settings with your inverter, and change language preferences.

  • APP Support System: iOS & Android
  • APP Download: Please contact Tewaycell support after receiving your battery to obtain the correct mobile APP and assistance with setup.
Bluetooth Connection and Mobile APP

Figure 13: Powerwall connected via Bluetooth to a mobile phone running the monitoring APP.

5.3. PC Monitoring Software

For detailed monitoring and parameter configuration, a PC monitoring software is available. This software provides real-time data, multi-monitoring views, parameter settings, system configuration options, and data export capabilities.

PC Monitoring Software Interface

Figure 14: Screenshot of the PC monitoring software interface showing various battery parameters and settings.

Battery Monitor on PC

Figure 15: Another view of the PC battery monitoring interface, displaying real-time data and memory information.

5.4. Battery Management System (BMS)

The Tewaycell Powerwall features a built-in smart BMS (Battery Management System) for optimal performance and safety. The BMS provides comprehensive protection and management functions:

  • Over Charge Protection
  • Overdischarge Protection
  • Power Display
  • Temperature Monitoring (NTC)
  • Automatic Battery Balancing
  • Current Protection
Built-in BMS Features

Figure 16: Diagram illustrating the protective features of the built-in BMS.

6. Maintenance

6.1. General Care

  • Keep the battery pack clean and free from dust.
  • Ensure adequate ventilation around the unit to prevent overheating.
  • Regularly check all cable connections for tightness and signs of wear.

6.2. Fire Protection Device

The Tewaycell Powerwall includes a built-in fire protection device. This device is designed to activate and release fire extinguishing material if the internal temperature reaches 180°C, enhancing safety.

Fire Protection Device

Figure 17: Location of the fire protection device within the battery unit.

7. Troubleshooting

If you encounter any issues with your Tewaycell Powerwall, please refer to the following general troubleshooting steps. For complex problems or persistent errors, contact Tewaycell technical support.

  • Alarm Indicator: If the alarm indicator on the top panel is lit, check the mobile APP or PC monitoring software for specific fault codes or status messages.
  • No Power Output: Verify that the power switch is ON, all cables are securely connected, and the Air Switch (if applicable) is in the ON position. Check the SOC indicator to ensure the battery has sufficient charge.
  • Communication Issues: Ensure the inverter cable is correctly connected to the communication ports (RS485/CAN/RS232). Check the settings in the mobile APP or PC software for correct communication parameters.
  • PC Monitoring Software Fault Status: The PC monitoring software provides detailed fault status information. Consult the software interface for diagnostic messages.

For any technical problems that cannot be resolved, please contact Tewaycell support. They are available 24 hours online to assist you.

8. Warranty and Support

The Tewaycell Powerwall LiFePO4 Battery Pack comes with a 10-year life expectancy and a 7-year warranty on the battery cells (AH).

For technical assistance, warranty claims, or any product-related inquiries, please contact Tewaycell customer support. Our team is available 24 hours online to provide assistance.

Tewaycell Certifications and Exhibition

Figure 18: Certifications (CE, SGS) and Tewaycell exhibition presence, demonstrating product quality and company reliability.

9. User Tips

  • Inverter Compatibility: Always double-check the compatibility of your inverter with the Tewaycell Powerwall's communication protocols (CAN, RS485, RS232) before purchase and installation. While many brands are supported, specific models may vary.
  • APP Download: To ensure you have the correct and latest version of the mobile monitoring application, contact Tewaycell support directly after receiving your battery. They will provide the appropriate download method and any necessary setup guidance.
  • System Expansion: If you plan to expand your energy storage system, remember that the Tewaycell Powerwall supports up to 16 units in parallel. Plan your wiring and air switch requirements accordingly for high current applications.

Related Documents - TW-MB48300-100A-APP

Preview Tewaycell Roller Type Mobile ESS Battery - User Manual and Specifications
Comprehensive user manual for the Tewaycell Roller Type Mobile ESS Battery. Learn about its LiFePO4 technology, safety features, applications in household energy storage, solar, and wind systems, and detailed operating instructions.
Preview Tewaycell Roller Type Mobile ESS Battery - Corporate Brochure and User Manual
Explore the Tewaycell Roller Type Mobile ESS Battery, a high-tech solution for green energy storage. This brochure and manual covers product features, technical specifications, safety instructions, operating procedures, and connection diagrams for LiFePO4 battery systems used in home energy storage, RVs, solar, and wind applications.
Preview Tewaycell AO Series Household All-in-One Energy Storage System User Manual
Comprehensive user manual for Tewaycell's AO series household all-in-one energy storage systems. Learn about installation, operation, safety features, and technical specifications for efficient green energy solutions.
Preview Tewaycell TW-AO-MB51300/MB51400 Inverter User Manual
Comprehensive user manual for Tewaycell's TW-AO-MB51300 and TW-AO-MB51400 inverters, covering installation, operation, maintenance, and technical specifications for green energy storage systems.
Preview Tewaycell TW-SK-HV Battery System User Manual
Comprehensive user manual for the Tewaycell TW-SK-HV series high voltage battery systems, covering product introduction, safety precautions, installation, operation, maintenance, and technical specifications.
Preview Tewaycell Energy Storage System: User Manual & Corporate Overview
Explore the Tewaycell Energy Storage System, featuring advanced inverters for solar power integration, battery management, and reliable energy solutions. This guide covers installation, operation, and technical specifications for efficient renewable energy management.